22
24
Battery equalization
voltage
48V model: default 58.4V, 48~60V Settable
25
Battery equalized time
Setting range is from 5 minutes to 900 minutes. Increment of
each click is 1 minute
26
Battery equalized
timeout
Setting range is from 5 minutes to 900 minutes. Increment of
each click is 1 minute
27
Equalization interval
Setting range is from 1 day to 30 days. Increment of each click
is 1 day
28
Equalization activated
immediately
Disabled (Default)
Enable
If equalization function is enabled in program 23, this
program can be set up. If “Enable” is selected in this
program, it‟s to activate battery equalization immediately and
LCD main page will shows “
”. If “Disable” is selected, it
will cancel equalization function until next activated
equalization time arrives based on program 27 setting. At this
time, “
” will not be shown in LCD main page.