background image

45

46

                             Model                            

Specifications

MID 

17KTL3-X1

MID 

20KTL3-X1

MID 

22KTL3-X1

MID 

25KTL3-X1

Protection devices 

DC reverse-polarity protection

YES

DC switch

YES

DC Surge protection

typeII OPT

Insulation resistance 

monitoring

YES

AC surge protection

typeII OPT

AC short-circuit protection

YES

Grid monitoring

YES

Anti-islanding protection

YES

Residual-current monitoring 

unit

YES

String Fuse protection

YES

String monitoring

OPT

AFCI protection

OPT

General data 

Dimensions (W / H / D) in mm

580*435*280mm

Weight

30.0kg

Operating temperature range

-25°C ... +60°C

(>45°CDerating)

Noise emission (typical)

50dB(A)

Altitude

4000m

Internal consumption at night

1W

Topology

Transformerless

Cooling

Smart air cooling

Electronics protection degree

IP66

Relative humidity

0~100%

DC connection

H4/MC4(OPT)

AC connection

Waterproof PG head+OT terminal or quick connect terminal

Interfaces

Display

OLED+LED

USB/RS485

YES

WIFI/GPRS/4G/RF/LAN

OPT

                             Model                            

Specifications

MID 

30KTL3-X

MID 

33KTL3-X

MID 

36KTL3-X

MID 

40KTL3-X

Input data(DC)

Max. recommended PV power(for 

module STC)

45000W

49500W

54000W

60000W

Max. DC voltage

1100V

Start voltage

250V

Nominal voltage

600V

MPP voltage range

200-1000V

No. of MPP trackers

3

4

No. of PV strings per MPP trackers

2/2/2

2/2/2

2/2/2/2

2/2/2/2

Max. input current per MPP 

trackers

26A*3

26A*3

26A*4

26A*4

Max. short-circuit current per MPP 

trackers

32A*3

32A*3

32A*4

32A*4

Backfeed current to PV array

                                                        0A

Output data(AC)

AC nominal power

30000W

33000W

36000W

40000W

Max. AC apparent 

33000VA

36300VA

39600VA

44000VA

Nominal AC voltage/range

230/400V

340-440V

AC grid frequency/range

50/60 Hz

45~55Hz/55-65 Hz

Max. output current

50.5A

55.5A

60.0A

66.6A

AC inrush current

60A

Max. output fault current

106.1A

106.1A

124.8A

124.8A

Max. output overcurrent 

Protection

106.1A

106.1A

124.8A

124.8A

Power factor(@nominal power)

>0.99

Adjustable power factor

0.8Leading ...0.8Lagging

THDi

<3%

AC grid connection type

3W+PE /3W+N+PE

Efficiency

Max. efficiency

98.8%

Euro-eta

98.5%

Summary of Contents for MID 17KTL3-X1

Page 1: ...henzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China 86 755 2747 1942 www ginverter com www ginverter com T E W service ginverter com service ginverter com 86 755 27...

Page 2: ...cation of skilled person 2 3 Safety instruction 4 Unpacking inspection 5 Installation 5 1 Basic installation requirements 5 2 Mounting wall mount 5 3 Installing the inverter 6 1 Security 6 2 AC side w...

Page 3: ...nty 15 Decommissioning 17 Specification 16 EU declaration of conformity 18 EU declaration of conformity 9 1 Boot display 9 2 OLED display wake up 9 3 Function setting 12 1 Start the inverter 12 2 Shut...

Page 4: ...ted to the Growatt device or cause personal injury 1 3 2 Markings on this product CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE i...

Page 5: ...nverter and other communication products to communicate with each other The wireless communication device is not standard Require to order extral if you need it Safety 2 2 1 Product description and fe...

Page 6: ...e incorrect installation and operation may lead to serious safety and shock hazards and or equipment damage In order to minimize the possibility of shock hazards due to dangerous voltages cover the en...

Page 7: ...ugh charge to create a shock hazard In order to minimize the occurrence of this situation observe all corresponding safety symbols and marks in this manual Under special circumstances the inverter may...

Page 8: ...k whether the outer package is damaged After unpacking please check whether the appearance of the inverter is damaged or lack of accessories If there is damage or missing parts please contact the deal...

Page 9: ...y of the installation environment should be between 0 and 90 The ambient temperature around the inverter should be between 25 C 60 C The inverter can be mounted on a plane that is tilted vertically or...

Page 10: ...wall for power or other piping before opening the hole in the wall Danger Secure the wall mount as shown do not let the screws flush with the wall instead expose 2 to 4 mm 5 3 Installing the inverter...

Page 11: ...gle core wire at the output terminal of the inverter It is forbidden to use aluminum wires as output cables Please ensure that the output cable is well connected before turning on the inverter Ignorin...

Page 12: ...witch Measure the voltage and frequency of the public grid voltage AC 230V frequency 50Hz The recommended specifications of the AC output switch are as follows Inverter model Switch specification MID...

Page 13: ...utput terminal before turning it on otherwise the inverter will be damaged If a stable non zero DC voltage is measured between the positive pole of the photovoltaic string and the ground it means that...

Page 14: ...ive connector Negative metal terminal 4 6mm 4 6mm Fig 6 7 Fig 6 8 Fig 6 9 1 2 3 4 B just for Vietnam models B just for Vietnam models A A Fig 6 10 Fig 6 11 Fig 6 12 Fig 6 13 2 Push the threaded sleeve...

Page 15: ...In this case the company does not carry out warranty and assumes any responsibility Photovoltaic panel Inverter Distribution Cabinet SPD Power grid Lightning protection device Grounding bar 1 2 3 4 To...

Page 16: ...the disconnection device Do not generate power Do not generate at more than 50 of rated power Do not generate at more than 75 of rated power and reduce the reactive power as far as possible Increase...

Page 17: ...n permanent shutdown The inverter has large electrical potential differences between its conductors Arc flashes can occur through air when high voltage current flows Do not work on the product during...

Page 18: ...uency return to normal the inverter will automatically connect to the grid 8 2 Failure mode The inverter controls the chip monitors and adjusts the state of the system in real time When the inverter m...

Page 19: ...er than the domestic legal requirements the inverter cannot be connected to the grid After obtaining the permission of the local power operator the user can choose other voltage levels according to th...

Page 20: ...0 2 USB A The inverter side The inverter side The inverter side The inverter side Unistall up Install USB A port is mainly used to connect monitoring module or firmware update We can connect the exter...

Page 21: ...ct terminal abnormal 1 Check the string terminal wiring after shutdown 2 If the fault message still exists contact the manufacturer Warning 202 DC lightning protection device alarm 1 Check the DC ligh...

Page 22: ...manufacturer Warning 305 Reverse connection of current transformer 1 Check whether the current transformer is connected reversely 2 If the fault message still exists contact the manufacturer Warning 3...

Page 23: ...line 2 If the fault information still exists contact the manufacturer Error 308 Pairing timeout 1 The pairing of the machine and the current transformer is overtime re pair 2 If the fault information...

Page 24: ...ttery reverse connection protection tube 1 Restart the machine 2 If the fault information still exists ontact the manufacturer Error 424 Battery voltage sampling is inconsistent 1 Restart the machine...

Page 25: ...voltage 1100V Start voltage 250V Nominal voltage 600V MPP voltage range 200 1000V No of MPP trackers 3 No of PV strings per MPP trackers 2 2 2 2 2 2 2 2 2 2 2 2 Max input current per MPP trackers 26A...

Page 26: ...RS485 YES WIFI GPRS 4G RF LAN OPT Model Specifications MID 30KTL3 X MID 33KTL3 X MID 36KTL3 X MID 40KTL3 X Input data DC Max recommended PV power for module STC 45000W 49500W 54000W 60000W Max DC volt...

Page 27: ...5 YES WIFI GPRS 4G RF LAN OPT Model Specifications MID 17KTL3 X1 MID 20KTL3 X1 MID 22KTL3 X1 MID 25KTL3 X1 Input data DC Max recommended PV power for module STC 25500W 30000W 33000W 375000W Max DC vol...

Page 28: ...YES WIFI GPRS 4G RF LAN OPT Model Specifications MID 30KTL3 X MID 33KTL3 X MID 36KTL3 X MID 40KTL3 X Input data DC Max recommended PV power for module STC 45000W 49500W 54000W 60000W Max DC voltage 11...

Page 29: ...aces Display OLED LED USB RS485 YES WIFI GPRS 4G RF LAN OPT 17 2 Torque Shell cover screw 12kgf cm AC terminal block 14kgf cm AC waterproof cover fixing screw 4kgf cm Security screws on the wall mount...

Page 30: ...act the Growatt New Energy Service Hotline We need the following information to provide you with the necessary help Inverter type Inverter serial number Inverter error message code Inverter OLED displ...

Reviews: