MIC 600TL-X 

MIC 750TL-X 

MIC 1000 TL-X 

MIC 1500 TL-X 

MIC 2000 TL-X 

MIC 2500 TL-X 

MIC 3000 TL-X 

MIC 3300 TL-X

 

 

Installation 

Operation Manual 

Summary of Contents for MIC 1000 TL-X

Page 1: ...1 MIC 600TL X MIC 750TL X MIC 1000 TL X MIC 1500 TL X MIC 2000 TL X MIC 2500 TL X MIC 3000 TL X MIC 3300 TL X Installation Operation Manual...

Page 2: ...com au T 61 2 8065 1298 H 1800 476 928 E australia ginverter com Please note Growatt reserve the ultimate explanation right on this warranty card Supplier is required to send the warranty claim form...

Page 3: ...t device In this case you do not receive a new certificate since your entitlement is documented at Growatt Failure to observe the user manual the installation guide and the maintenance regulations Una...

Page 4: ...he unit 16 4 Unpacking and inspection 16 5 Installation 17 5 1 Safety instructions 18 5 2 Selecting the installation location 19 5 3 Mounting the Inverter 22 5 3 1 Mounting the Inverter with bracket 2...

Page 5: ...r Quality Response Modes PQRM 45 7 3 2 Generation Export limitation control and Power Sensor setting 46 7 3 3 Reset factory 48 7 3 4 Adjust the setpoints from the regional default values 48 7 4 Commun...

Page 6: ...4 14 Technical Data 57 14 1 Specification 57 14 2 DC AC connector info 60 14 3 Torque 60 14 4 Accessories 61 15 Compliance Certificates 61 16 Contact 61...

Page 7: ...market 1 2 Target Group This manual is for qualified personnel Qualified personnel have received training and have demonstrated skills and knowledge in the construction and operation of this device Q...

Page 8: ...description DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result...

Page 9: ...s Point of connection for grounding protection Direct Current DC Isolation Switch Alternating Current AC Read the manual CE mark The inverter complies with the requirements of the applicable CE guidel...

Page 10: ...t power feeding into the power distribution grid and the maximum power of the inverter that can feed into the power distribution grid Power Factor Power factor is the ratio of true power or watts to a...

Page 11: ...intended use The manufacturer supplier is not liable for damage caused by such unintended use Damage caused by such unintended use is at the sole risk of the operator PV modules Capacitive Discharge C...

Page 12: ...the instructions in this manual Use care when choosing installation location and adhere to specified cooling requirements Unauthorized removal of necessary protections improper use incorrect installat...

Page 13: ...vailing safety regulations to minimize risk of accidents Systems with inverters typically require additional control e g switches disconnects or protective devices e g fusing circuit breakers dependin...

Page 14: ...in this manual In special cases there may still be interference for the specified application area despite maintaining standardized emission limit values e g when sensitive equipment is located at the...

Page 15: ...ol Touch button We can switch the OLED display and set parameter by touching Inverter status symbol Indicates inverter operation status Red Fault Green Nomal Red leaf flash Warning or DSP Programming...

Page 16: ...range 50V 500V AC nominal voltage 230V AC grid frequency 50 60 Hz Max apparent power 600VA 750VA 1000VA 1500VA AC normal output current 2 6A 3 3A 4 3A 6 5A Power factor 0 8leading 0 8lagging Environm...

Page 17: ...ate location to store the inverter The unit must be stored in original package and desiccant must be left in the package Max input DC current 13A Start voltage 80V MPP voltage range 65V 550V AC nomina...

Page 18: ...s leave our factory in proper electrical and mechanical condition Special packaging ensures safe and careful transportation However transport damage may still occur The shipping company is responsible...

Page 19: ...unting bracket 1 C Quick Guide 1 D Monitor Optional 1 E Signal connector 1 F DRED connector 1 G Self tapping screws 3 H Safety lock screw 2 I Plastic expansion pipe 3 J PV PV terminal 1 1 K PV PV meta...

Page 20: ...pliance to EMC regulations for the complete system All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inverter contains no u...

Page 21: ...id potential damages to device and operators The installation location must be suitable for the inverter s weight and dimensions for a long period time Select the installation location so that the sta...

Page 22: ...Inverter requires adequate cooling space Providing better ventilation for the inverter to ensure the heat escape adequately The ambient temperature should be below 40 C to ensure optimum operation Do...

Page 23: ...ary increase the clearance spaces and make sure there is enough fresh air supply to ensure sufficient cooling of the inverters The inverter can t install to solarization drench firn location We sugges...

Page 24: ...racket DANGER In order to avoid electrical shock or other injury inspect existing electronic or plumbing installations before drilling holes Fix the mounting bracket as the figure shows Do not make th...

Page 25: ...mounting frame is really firmly mounted on the wall after carefully checking Rise up the inverter a little higher than the bracket Considered the weight of them During the process please maintain the...

Page 26: ...S485 A 6 1 Safety Danger to life due to lethal voltages High voltages which may cause electric shocks are present in the conductive parts of the inverter Prior to performing any work on the inverter d...

Page 27: ...you must choose a Type B RCD breaker with the rating residual current not less than 300mA You must install a separate single phase circuit breaker or other load disconnection unit for each inverter i...

Page 28: ...through pressure screw seal ring threaded sleeve in sequence insert cables into connection terminal according to polarities indicates on it and tighten the screws firmly Please try to pull out the wi...

Page 29: ...27 3 Push the threaded sleeve into the socket Tighten up the cap on the terminal 4 Finally Push or screw the threaded sleeve to connection terminal until both are locked tightly on the inverter...

Page 30: ...28 5 To remove the AC output terminal press the bayonet out of the slot with a small screwdriver and pull it out or unscrew the threaded sleeve then pull it out...

Page 31: ...29 Wire suggestion length Conductor cross section Max cable length MIC 600 750 TL X MIC 1000 TL X MIC 1500 TL X 2 0mm 14AWG 72m 54m 37m 3 3 mm 12AWG 120m 90m 61m...

Page 32: ...ith a conductor cross section of at least 10 mm Cu Or Install a second protective conductor on the earth terminal with the same cross section as the original protective conductor on the AC terminal Th...

Page 33: ...VER connect or disconnect the DC connectors under load Make sure the maximum open circuit voltage Voc of each PV string is less than the maximum input voltage of the inverter Check the design of the P...

Page 34: ...threaded sleeve in sequence insert cables into connection terminal according to number indicates on it and tighten the screws firmly Please try to pull out the wire to make sure the it s well connect...

Page 35: ...to the socket Tighten up the cap on the terminal Step 3 Push the threaded sleeve to connection terminal until both are locked tightly on the inverter Uninstall signal connector Step 1 Press the fasten...

Page 36: ...unding the inverter The inverter must be connected to the AC grounding conductor of the power distribution grid via the ground terminal PE WARNING Because of the transformerless design the DC positive...

Page 37: ...r multiple inverter combination The export limit control function for an inverter is used to control the generation from an inverter or multiple inverter combination to manage the export power level f...

Page 38: ...time 3s Installation category CAT II Mechanical Environment M1 Electromagnetic environment E2 Degree of pollution 2 Mechanics Din rail dimensions 18x118x64 WxHxD DIN 43880 Mounting DIN rail 35mm Ingre...

Page 39: ...netration All the warranty claim will be invalid WARNING Excessive voltage can damage the inverter External voltage of DRM PORT don t over 5V 6 8 1 RJ45 pin assignment Pin Assignment for inverters cap...

Page 40: ...t 3 Relay contact 3 input K3 Relay 3 output 4 Relay contact 4 input K4 Relay 4 output 5 GND Relays common node 6 Not connected Not connected 7 Not connected Not connected 8 Not connected Not connected...

Page 41: ...Electrical Code R Section 690 11 stipulates that newly installed PV systems attached to a building must be fitted with a means of detecting and disconnecting serial electric arcs AFCI on the PV side 6...

Page 42: ...lready set up When the Earth fault occurs the Red LED will light up The buzzer in the inverter will keep ringing unless the fault condition is cleared This function is o nly avilable for Australia and...

Page 43: ...defaut value 7 1 2 Country Area and Region setting Information Country Area and Region setting When the inverter start up the installer need to select the right country if the installer don t select a...

Page 44: ...grid protection settings 7 1 3 Enabling Disabling Power Quality Response Modes PQRM Information PQRM setting When the Region setting is completed the inverter will operate under default mode different...

Page 45: ...Single touch to switch different language Double touch to confirm you setting Set the language as described below 7 2 2 Set inverter COM address The default COM address is 1 We can change COM address...

Page 46: ...44 Double touch to confirm you setting 7 2 3 Set inverter date time Single touch make the number 1 Double touch to confirm you setting Hold 5s recover defaut value...

Page 47: ...Region and Power Quality Response Modes PQRM Single touch to switch display or make the number 1 Double touch to confirm you setting Input right password you can change Country Area Region and PQRM se...

Page 48: ...to switch display or make the number 1 Double touch to confirm you setting Control type SW stands for enabling software limit control function HW stands for enabling hardware limit control function Bo...

Page 49: ...ergy provider the ratio of your system output power divide d by the rated power of the inverter is called Limit Rate For instance if the energy provider only ac cepts 1kVA kW from your 2kW system then...

Page 50: ...ameters will be restored to their factory defaults Single touch to switch display or make the number 1 Double touch to confirm you setting Input right password you can reset factory default setting 7...

Page 51: ...SB connection we can connect external optional monitor for example Shine WIFI X Shine 4G X Shine LAN X ect And also you can quickly update the software by U disk We can monitor as below Make sure the...

Page 52: ...4 Waiting until LED OLED have go out the inverter is shut down 9 Maintenance Repair and Cleaning WARNING Prior to removal of any cover for maintenance or repair turn off the switch on the AC and DC s...

Page 53: ...nzhen Growatt New Energy Technology Co Ltd confirms that the Growatt inverters and accessories described in this document are in compliance with the above mentioned EU directives The entire EU Declara...

Page 54: ...ggestion Residual I High Error 201 Leakage current too high 1 Restart the invert 2 If error message still exists contact Growatt PV Voltage High Error 202 The DC input voltage is exceeding the maximum...

Page 55: ...utral and PE 2 Check AC wiring 3 Restart inverter if error message still exisits contact Manufacturer AC F Outrange Error 304 Utility grid frequency out of permissible range Please switch off DC switc...

Page 56: ...er service to replace the power board Warning207 USB over current 1 Unplug the U disk or monitor 2 Re access U disk or monitor after shutdown 3 If the error message still exists contact manufacturer W...

Page 57: ...ist Contact Growatt Error 411 DSP communicates with M3 abnormal Restart inverter if problem still exist update the DSP M3 firmware Change DSP board or M3 board if problem still exist contact Growatt E...

Page 58: ...the inverter in its original carton and secure it with tension belts If it is no longer available you can also use an equivalent carton The box must be capable of being closed completely and made to s...

Page 59: ...MPP trackers 16A Output data AC Rated output power 600W 750W 1000W 1500W Rated apparent power 600VA 750VA 1000VA 1500VA Max AC apparent power 600VA 750VA 1000VA 1500VA Nominal AC voltage range 230 18...

Page 60: ...y Drift Residual current monitoring unit Integrated General data Dimensions W H D in mm 274 254 138 Weight 6 0 kg Operating temperature range 25 C 60 C Noise emission typical 25 dB A Altitude 4000m In...

Page 61: ...y range 50 60Hz 44 55Hz 54 65Hz Rated output current 8 7A 10 9A 13A 14 3A Max output current 9 5A 11 9A 14 3A 14 3A Initial short circuit AC current 8 7A 10 9A 13A 14 3A Inrush current 10A Max output...

Page 62: ...ht 0 5W Topology Non isolated Cooling Natural convection Protection degree IP65 Relative humidity 0 100 DC connection VP D4 H4 opt AC connection AC connector Interfaces Display OLED LED RS485 USB Inte...

Page 63: ...so be expressly exclude as are all other related logistical and process costs incurred by all parties in relation to this warranty claim 15 Compliance Certificates Certificates With the appropriate se...

Page 64: ...62 www ginverter com Serviceline Tel 86 755 2747 1942 Email service ginverter com...