background image

6

5

When  installing  or  using  a  battery  system,  the  safety  information  contained  in  this 
section must always be followed. For safety reasons, it is the installer's responsibility to 
be familiar with this manual and all warnings before installation.

2.1 Basic security

The battery system has been designed and tested in accordance with strict rules with 
international safety certification requirements. Before any installation or use of the 
battery system, please read all safety instructions carefully and always follow the relevant 
rules. Growatt is not responsible for any consequences resulting from violation of the 
following regulations:

Ÿ

Damage occurred during transportation.

Ÿ

Incorrect transportation, storage, installation and use, or customer fails to convey the 

correct information about transportation, storage, installation and use to terminal 
customers. 

Ÿ

Non-professional installation.

Ÿ

Failure to obey the rules of this operation instructions and safety precautions in this 

document.

Ÿ

Unauthorized modifications or removal of the software package.

Ÿ

The product's tamper label is damaged or the product lacks any parts (except 

authorized disassembly parts).

Ÿ

Operation in extreme environments which are not allowed in this document.

Ÿ

Repair, disassemble, or change PACKs without authorization and cause failure.

Ÿ

 Damage to shell labels or modifies date of production. 

Ÿ

Battery packs fail to be charge for more than six months. 

Ÿ

Damages due to force majeure (such as lightning, earthquakes, fire, and storms).

Ÿ

Warranty expiration.

2.2 Safety Precautions

2.2.1 Environmental requirements

Ø

Do not expose the battery to temperature above 50

℃ 

or heat sources.

Ø

Do not install or use the battery in wet locations, moisture, corrosive gases or liquids, 

such as bathroom. 

Ø

 Do not expose the battery to direct sunlight for extended periods of time.  

Ø

Place battery in safe place away from children and animals.

Ø

Battery power terminals shall not touch conductive objects such as wires. 

Ø

Do not dispose the batteries in fire, which may cause an explosion.

Ø

The battery system shall not come in contact with liquids.

 

Safety 

2.2.2 Operation Precautions

Ø

Do not touch the battery system with wet hands.

Ø

Do not disassemble the battery system without permission.

Ø

Do not crush, drop or pierce the battery pack and high voltage controller.

Ø

Dispose the batteries according to local safety regulations.

Ø

Store and recharge battery in accordance with this manual.

Ø

Ensure the connection of ground wire reliable.

Ø

Remove all metal objects such as watches and rings that could cause a short-circuit 

before installation, replacement and maintenance.

Ø

The system should be installed, repaired, replaced or maintained by skilled person or 

instructed person

ª

Skilled person  

        Person with relevant education and experience to enable him or her to perceive risks
        and to avoid hazards which the equipment can create .
        Note 1 to entry: Such person has access to restricted access areas
        [SOURCE: IEC 60050-195:1998, 195-04-01, Modified – The word “(electrically)” 
        has been deleted from the term, and “electricity” has been replaced by “the 
        equipment” in the definition. The note has been added.]   

ª

Instructed person

        Person adequately advised or supervised by skilled persons to enable him or her to 
        perceive risks and to avoid hazards which the equipment can create
        Note 1 to entry: Such person has access to restricted access areas 
        Note 2 to entry: Examples of activities performed by an instructed person can be 
        found in IEC 61140:2001, Clause 8.
        [SOURCE: IEC 60050-195:1998, 195-04-02, Modified – The word “(electrically)”   
        has been deleted from the term, and the notes have been added.]

Ø

When storing or handling batteries, do not stack batteries without package.

Ø

Do not broke the battery, the released electrolyte may be toxic and is harmful to skin 

and eyes.

Ø

Packaged batteries should not be stacked more than specified number stipulated on 

the packing case.

Ø

Do not use damaged, failed or deformed batteries, which may lead to high 

temperature or even dangerous accidents. Continued operation of damaged battery may 
result in electrical shock, fire or even worse. 

2.3 Warning Labels

Symbols

Description

Operation after 5 minutes after disconnecting the power supply 
(including disconnect/connect power wiring)

Do not dispose in trash

Lithium ion battery can be recycled

Certification in European union area

Electric shock hazard

Summary of Contents for ARK 5.1-25.6XH-A1

Page 1: ...w Energy Co Ltd 86 755 2747 1942 www ginverter com T E W service ginverter com GR UM 242 A 00 ARK 5 1 25 6XH A1 High Voltage Battery System User Manual V1 0 4 13 F Building A Sino German Europe Indust...

Page 2: ...rements 4 2 Installation Required Tools 4 3 Installation Procedures 4 4 Electrical Connection About this Document This document describes the installation electrical connection operation commission ma...

Page 3: ...duct is shown as below Fig 1 2 Schematic diagram of power panel Location Port Function 1 POWER Wake up battery 2 INV Port for communication with hybrid inverter 3 Link in Battery system in parallel co...

Page 4: ...ery management units power and signal terminals and mechanical parts Compared with other battery systems it has better charging and discharging performance higher charging and discharging efficiency m...

Page 5: ...with liquids Safety 2 2 2 2 Operation Precautions Do not touch the battery system with wet hands Do not disassemble the battery system without permission Do not crush drop or pierce the battery pack...

Page 6: ...u touch the leaking electrolyte do as below immediately Inhalation Evacuate the contaminated area and seek medical help Eye contact Rinse eyes with flowing water for 15 minutes and seek medical help S...

Page 7: ...l damages Prohibit to pile up more than six battery pack There will be a drop in capacity during transportation and storage Transportation temperature is between 20 C to 45 C relative humidity 5 95 RH...

Page 8: ...system Drill Screw Driver Wrench Pencil Tap Measure Multimeter It is recommended to wear the following safety gear when dealing with the battery system Insulated Glove Safety Goggle Safety Shoes 4 3...

Page 9: ...s a row only one battery base is required and two rows are required two And the wall bracket is only used for wall installation The number of wall brackets are determined by the number of battery modu...

Page 10: ...Fig 4 9 Multiple battery installation process with wall mount 4 3 3 Floor Standing Installation Step 1 Choose an alloy drill with a diameter of 8mm and drill at least 50mm mounting holes on the wall C...

Page 11: ...nts front view Pin assignments front view BDC 95045 A1 communication interface MOD TL3 XH Hybrid inverter three phase interface Silk screen Terminal serial number Definition Silk screen Terminal seria...

Page 12: ...onnect the ommunication plug of the last battery pack otherwise it will cause system failure Note 4 4 2 2 Electrical wiring connection A BDC 95045 A1 High voltage controller wiring Step 1 Insert the p...

Page 13: ...ration Please stand on dry insulating objects and do not wear conductive material such as watches and necklace during operation Insulated tools should be used Do not contact any positions with potenti...

Page 14: ...ransport the battery pack or High voltage controller to the designated repair site Install new battery pack or High voltage controller based on procedure specified in Section 4 6 3 System Failure Info...

Page 15: ...ller to repair battery Technical Specifications7 7 1 ARK XH A1 high voltage system System Model ARK 5 1XH A1 ARK 7 6XH A1 ARK 10 2XH A1 ARK 12 8XH A1 ARK 15 3XH A1 High Voltage Controller Model BDC 95...

Page 16: ...tage battery packs Voltage after series Single phase power conversion system allows 2 7PCS battery modules in series its nominal voltage is 400V Three phase power conversion system allows 3 10PCS batt...

Page 17: ...ging to 650V of DC DC output Module side voltage and current is limited by DC DC circuit ARK 20 4XH A1 IFpP 41 150 102 1P16S 8S M 10 50 90 constant current 15A charging to 650V of DC DC output Module...

Page 18: ...licker green Protection Charge and discharge Over current hardware protection SOC indicates current remaining capacity t 1S RUN ALM light flicker green Ambient temperatur e over temperatur e alarm t 1...

Page 19: ...ilure protection t 1S RUN ALM light flicker red Main circuit failure protection t 1S RUN ALM light flicker red EEPROM fault protection t 1S RUN ALM light flicker red Front end chip failure protection...

Reviews: