Fault/ cause/ remedy
Fault
Cause
Remedy
Indicator lamp on front
of electronics flashing
continuously after calibration
• Obstacle during calibration
- Perform calibration again, ensuring there
is no obstacle in the adjustment range of
the servo motor, see Maintenance,
Calibrating the servo motor
• Servo motor defective
- Replace servo motor, see Maintenance,
Replacing the servo motor
No flushing
• Water supply interrupted
- Open isolating valve in cistern
• No voltage (indicator lamp on back of
electronics not flashing)
- Switch on power supply or check plug-in
connection or transformer defective, see
Maintenance, Replacing the transformer
• Electronics defective (indicator lamp not
flashing or permanently on)
- Replace electronics, see Maintenance,
Replacing the wall plate with electronics
• Servo motor defective (no rotation)
- Replace servo motor, see Maintenance,
Replacing the servo motor
• Plug-in connector without contact
- Attach plug-in connector
• The detection zone of the sensor system
is set too low/too high
- Increase/reduce detection zone using
remote control (special
accessory 36206)
Water flowing continuously
• Outlet valve not closing
- Adjust servo motor position, see
Calibrating the servo motor, or outlet
valve defective (repair, replace, observe
replacement part), see cistern
instructions
Undesired flushing
• The detection zone of the sensor system
is set too high
- An opposing object is detected. Reduce
detection zone using remote control
(special accessory 36206)
Flow volume too low
• Flow volume set too low
- Adjust flow volume, see Setting the flow
volume
• Outlet valve does not lift fully out
- Adjust servo motor position, see
Calibrating the servo motor
• Servo motor defective (incomplete
rotation)
- Replace the servo motor, see
Maintenance, Replacing the servo motor
• Residual flow rate too high
- Push residual flow slider downwards, see
Preparations, Fig. [10a]
• Flow rate in cistern too low
- Turn float of filler valve further upwards,
see Preparations, Fig. [8]
Flow volume too high
• Flow volume set too high
- Adjust the flow volume, see Setting the
flow volume
Summary of Contents for Tectron 38 698
Page 3: ...II 11a 3 5 8 12b 12a 6 4 A B 1 13 10a 7 2 N5 V1 14a 14b 9a ...
Page 48: ...45 ...
Page 49: ...46 ...
Page 50: ...47 ...
Page 51: ...48 48 ...
Page 112: ...III 17 18 19 21 24 25 27 26 22 23 20 16 15b 15a ...
Page 113: ...IV 1 2 2 1 ...
Page 114: ......
Page 115: ......
Page 116: ......