background image

6

Technical Data

Functioning Principle

The 

Grohsafe 

pressure balance valve is a 

safety mixer designed to compensate for 
fluctuations in the water supply pressures, 
which would otherwise affect the mixed 
water temperature.

This product is supplied with connectors to fit 
ø 15mm pipework with inlet connections 
apart 150mm. Connection should be hot left, 
cold right as viewed from the operating 
position. The product is preassembled, as 
standard, with the 

outlet down

For reversed supply installations refer to 
page 10.

Plumbing Systems

Suitable for use with multi-point gas water 
heaters or combination boilers with a modu-
lating hot water output. To maintain sufficient 
hot water output ensure the combination 
boiler temperature setting is on 

high

. Also 

suitable for mains pressure unvented and 
instantaneous thermal hot water storage 
systems.

Not suitable

 for instantaneous hot water 

displacement heaters or gravity-fed plum-
bing systems with an open vented hot water 
cylinder and cold water storage cistern.

Supply Pipework

Ensure the supply pipework is thoroughly 
flushed before installing the mixing valve. 
GROHE recommends installing isolating 
valves upstream of the mixing valve for 
servicing purposes, and in-line strainers to 
prevent the ingress of water borne debris.

New Water Regulations

This GROHE-product is designed to comply 
with the current Water Bylaw 17 and the new 
Water Regulations covering back-flow pre-
vention. It must be installed in accordance 
with local authority bye-laws. Incorrect instal-
lation could contravene bye-law installation 
requirements.

Specification

Exposed single handle pressure balancing 
shower valve, concealed supplies, with 
shower set.

Integral non-return valves prevents cross 
flow.

The pressure balance valve cartridge is a 
safety mixer and will shut off in the event 
of total pressure failure of the hot or cold 
water supplies.

Flow pressure

-  min. 

          1 bar

-  recommended 

 1.5 - 5 bar

-  greater than 5 bar, fit pressure reducing 

valve

Max. operating pressure 

       10 bar

Max. test pressure 

       20 bar

Flow rate at 3 bar pressure:      

          approx. 15.5 l/min

Temperature

- Max. (hot water inlet) 

         80 

°

C

- Recommended (for economy)        60 

°

C

- Max. outlet temperature is reached 

when handle is turned counter-clock-
wise through 270

°

- Max. outlet temperature can be pre-set 

using the adjustable hot water limit stop.

- Temperature ac/- 1 

°

C with 50% 

pressure drop of hot or cold supplies.

Water connection 

  hot -    LH

 

  cold - RH

- Installation with reversed supplies 

possible by rotating the cartridge 180

°

Summary of Contents for Grohsafe 35 237

Page 1: ...2 RUS 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Grohsafe Grohsafe 95 064 331 M 205474 01 06 35 237 GB 5 I 5 N 9 GR 13 TR 17 BG 21 RO 25 GB 2 NL 6 FIN 10 CZ 14 SK 18 EST 22 RU...

Page 2: ...dy Stop Handle Screw Cap Chassis Handshower Shower Rail Flexible Hose Filter Backplate Screws Clips Screws and wallplugs Scale Ring Screws Washers Screws Nipple Table Of Contents Installation Dimensio...

Page 3: ...II Spare Parts 3 4 Spare Parts Spare Parts...

Page 4: ...e from this fitting No Description Cat No Pack ing unit 8 Handshower 28 422 1 9 Filter 07 002 2 10 Shower rail 28 666 1 10 1 Sliding shower holder 07 659 1 10 2 Shower rail holder 45 362 1 10 2 1 Cove...

Page 5: ...ating valves upstream of the mixing valve for servicing purposes and in line strainers to prevent the ingress of water borne debris New Water Regulations This GROHE product is designed to comply with...

Page 6: ...ections of the supply pipes i e exposed beyond the wall sur face have the correct length 13 18mm and distance 150mm see Fig 1 2 Place the backplate A with the fillet A1 onto the mixer body B Make sure...

Page 7: ...he valve body B to the backplate with clips E and screws F Do not use excessive force to tighten the screws E 10 Tighten the compression nuts torque min 20 Nm see Fig 7 11 Slide the chassis G with the...

Page 8: ...crews M1 15 Push adjustable hot water limit stop N to the intermediate handle H as de scribed in Fig 11 Please refer to chapter Maximum Hot Water Limit Setting on page 11 for limiting maximum outlet t...

Page 9: ...e the four corner screws S1 and valve cover S 10 Pull the pressure balancing cartridge T out of the valve body Do not damage the O ring seals see Fig 14 Reverse the pressure balancing cartridge 180 by...

Page 10: ...Fig 15 2 Detach hot water limit stop N 3 Turn the intermediate handle H counter clockwise until the outlet water reaches the desired temperature see Fig 16 4 Place the hot water limit stop N over the...

Page 11: ...dy noting the location of H and C marking near the cartridge inlets The pressure balancing cartridge T must be replaced as a complete unit Reassemble in reverse order Ensure the two alignment pins T1...

Page 12: ...vironment friendly cleaning liquid Grohclean is specially formulated to gently clean the surface of our fittings Problem Cause Remedy Shower control opening through hot Hot and cold water supplies hav...

Page 13: ...14...

Page 14: ...nctional defects for which we are responsible limitations see E F B It is our option if we correct the defects by repair or replacement C During the above guarantee period we will not charge for the c...

Reviews: