3
Proceed as follows for fittings:
1. Disconnect battery and power supply unit, see fold-out
page II, Fig. [10] or [11].
2. Wait approx. 10 seconds.
3. Reconnect battery and power supply unit. There are two
brief water pulses after 10 seconds.
4. Register the new digital controller within the next
60 seconds by simultaneously pressing
On/Off
and
+
.
5. The fitting is then ready for operation again.
Proceed as follows for thermostat boxes:
1. Disconnect power supply unit or, see fold-out page II,
Fig. [12].
2. Wait approx. 10 seconds.
3. Reconnect power supply unit or.
4. Wait 10 seconds. Register the new digital controller
within the next 60 seconds by simultaneously pressing
On/Off
and
+
.
5. The thermostat box is ready for operation again after a total
of 3 minutes. The buttons on the digital controller/diverter
are inoperative during this time.
Function F3 - Register/de-register additional (max. 3) digital controller (36 309)/diverter (48 113/48114).
Start of the function menu
only
when no water is flowing.
Button
Description
Visualization
Start the function menu
- Select the function by simultaneously pressing and holding the
- / +
buttons.
-
F3
Function
select by turning the ring
•
Start F3
- Register additional digital controller/diverter
=> Confirm by simultaneously pressing the
- / +
buttons.
- Press the buttons
1
+
3
of the additional digital controller/diverter
simultaneously in order to register it.
- Pressing the
- / +
buttons simultaneously on the pending digital controller
saves the selection and exits the menu.
•
Start F3
- De-register additional digital controller/diverter
=> Confirm by simultaneously pressing the
- / +
buttons.
- Pressing the
- / +
buttons simultaneously on the factory digital controller to
de-register all additional controllers/diverters.
Abort
the function menu by pressing and holding
Start/Stopp
button or after
3 minutes without triggering.
Illuminated ring flashes red 1x.
Illuminated ring flashes red 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Fault
Cause
Remedy
No function
• No voltage supply
• Digital controller/diverter not ready or
registered
- Connect voltage supply
- Register digital controller/diverter
• Digital controller/diverter out of range
• Radio interference
Obstacle in transmission path
- Reduce distance or use special accessory
transceiver (order no 36 356)
- Deactivate potential source of interference and
check function again => If positive reconfigure the
interference source (eg wireless router)
- Rectify the fault see section
Operating conditions
•
1x:
Batteries digital controller/diverter
almost empty
•
2x and water pulses:
Battery
functional unit almost empty
•
2x without water pulses:
Battery
functional unit not connected or empty
•
3x:
Temperature too high
•
4x:
Pump runs dry
•
5x:
Calibration servo motor not
completed
- Check installation or replace unit battery
- Check installation or replace unit battery
- Connect plug in-connector battery or replace
battery
- Wait until feeler gauge is cooling down
- Calibrate functional unit
- Prime pump
- Wait 3 minutes, switch off the voltage supply and
reconnect
• Software malfunction
- Switch off the voltage supply and consult a
specialist installer or the GROHE Service Hotline
• Hard- or software malfunction
- Switch off the voltage supply and consult a
specialist installer or return the product to GROHE
Disposal instructions
This category of device does
not
belong in the domestic waste, but
must
be disposed of separately in accordance
with the relevant local national regulations.
Dispose of batteries in accordance with national regulations.
Segment flashes 1x
white
Segment flashes
green
Segment flashes 1x
yellow
Segment flashes 1x
red