background image

7302465-100 (6/20)

1.   Install Closet Bolts - Install closet bolts in 

flange channel and slide into place parallel  
to wall.

2.  Invert toilet on floor (cushion to prevent 

damage), and install wax ring evenly around 

waste flange (horn), with tapered end of ring 

facing toilet.

3.    Tip - Place 2 pieces of masking tape on floor 

and on bowl (as shown) to help with alignment 
in step 4.

4.    Apply weight evenly. Do not move after  

placement. Water tight seal may break. 

5.  Apply washer & nut over Closet Bolt and 

tighten. Do not over tighten nuts or damage to 
china may exist.

6.   Install Tank 

•  Insert rubber grommets through holes in the 

tank then insert bolts through holes in the 
grommets.

    •  Install large rubber gasket over threaded 

outlet on bottom of tank and lower tank onto 
bowl so that tapered end of gasket fits evenly 
into bowl water inlet opening.

    •   With tank parallel to wall, alternately  

tighten nuts until tank is snugged down 
evenly against bowl surface.

CAUTION: DO NOT overtighten nuts more than 
required for a snug fit. 
WARNING: Connect water supply hose.  
Overtightening of water supplyline nuts could 
result in breakage and potential flooding. If the 
connection leaks after handtightening, replace 
the supplyline. Do not use any type of sealant  
on the water supply connection.
Use of plumber’s putty, pipe dope, or any  
other type of sealant will void the warranty.
Adjust water level. Water level should be  
adjusted to level indicated on sticker inside  
of tank.

 

7.      Adjust  Water  Level: EUROCUBE by pulling 

water level adjustment switch (up) to ON on the 
Fill Valve, then pull the Fill Valve up or down to 
desired water level. Lock Fill Valve in place by 
pushing switch (down) to OFF. Flush toilet while 
observing water level. Continue to adjust flush 
valve until correct water level is obtained.

     Turn on water supply. Check for proper flush 

operation.

8.      Adjust Water Level: ESSENCE Turn on  

water supply. Submerge the FLOAT CUP 
under the water for 30 seconds. Adjust the 
water to desired level by turning WATER 
LEVEL ADJUSTMENT ROD and moving 
FLOAT CUP  up or down.

9.  Flush Push Buttons 

•   The large flush button should line up  

over the  white actuator on the flush  
tower in the tank.

    •   The small flush button should line up  

over the  gray actuator on the flush  
tower in the tank.

    •  Pressing both buttons at once  

will result in a  short flush.

INSTALLATION INSTRUCTIONS 

          

10.   Tips: 

With the lid removed, directly press 
the flush button  in the tank to confirm 
that the toilet is working  properly.  
•  Install Threaded Rods into holes in 

bottom of push buttons approxi-
mately 1/2" (12 mm).

    • Lightly snug Locking Nut.
    • Place Lid on Tank.
    •  Push Button to test flush. If more 

stroke is  needed, loosen Locknut and 
turn Threaded Rod  counterclockwise 
one (1) turn.

    •  Replace Lid. Repeat until flush action 

is achieved.

    •  If Valve stays open, turn Threaded 

Rod clockwise  one (1) turn and lightly 
snug Locknut.

Care and Cleaning - When cleaning your 
toilet, wash it with mild, soapy water, rinse 
thoroughly with clear water and dry with 
a soft cloth. Avoid detergents, disinfec-
tants, or cleaning products in aerosol cans. 
NEVER use abrasive scouring powders or 
abrasive pads on your toilet seat. Some 
bathroom chemicals and cosmetics may 
damage the seat's finish.
WARNING: Do not use in-tank cleaners. 
Products containing chlorine (calcium 
hypochlorite) can seriously damage fittings 
in the tank. This damage can cause leakage 
and property damage. Grohe shall not be 
responsible or liable for any tank fitting 
damage caused by the use of cleaners con-
taining chlorine (calcium hypochlorite).

For seat installation, see instructions 
included with seat.

8

10

9

LARGE FLUSH BUTTON

FOR  SOLID WASTE 

1.28 gal/flush

4.8 Liter/flush

Locknuts

Threaded Rods

SMALL FLUSH BUTTON
FOR  LIQUID WASTE
1.0 gal/flush
3.8 Liter/flush

BOUTON GRAND DÉBIT POUR 

DÉCHETS SOLIDES

1,28 gallon par chasse

4,8 litres par chasse

BOUTON PETIT DÉBIT POUR 

DÉCHETS LIQUIDES

1,0 gallon par chasse

3,8 litres par chasse

Contre-écrous

Tiges filetées

BOTÓN DE DESCARGA 

GRANDE PARA DESECHOS 

SÓLIDOS

1.28 galones/descarga

4.8 Litro/descarga

Tuercas de retención

Varillas roscadas

BOTÓN DE DESCARGA PEQUEÑO 
PARA DESECHOS LÍQUIDOS
1.0 galones/descarga
3.8 Litro/descarga

EUROCUBE

ESSENCE

FLUSH PUSH BUTTONS  
BOUTONS POUSSOIR DE CHASSE
  
BOTONES DE PRESIÓN DE DESCARGA

LARGE FLUSH BUTTON

FOR  SOLID WASTE 

1.28 gal/flush

4.8 Liter/flush

Locknuts

Threaded Rods

SMALL FLUSH BUTTON
FOR  LIQUID WASTE
1.0 gal/flush
3.8 Liter/flush

BOUTON GRAND DÉBIT POUR 

DÉCHETS SOLIDES

1,28 gallon par chasse

4,8 litres par chasse

BOUTON PETIT DÉBIT POUR 

DÉCHETS LIQUIDES

1,0 gallon par chasse

3,8 litres par chasse

Contre-écrous

Tiges filetées

BOTÓN DE DESCARGA 

GRANDE PARA DESECHOS 

SÓLIDOS

1.28 galones/descarga

4.8 Litro/descarga

Tuercas de retención

Varillas roscadas

BOTÓN DE DESCARGA PEQUEÑO 
PARA DESECHOS LÍQUIDOS
1.0 galones/descarga
3.8 Litro/descarga

EUROCUBE

ESSENCE

TIPS:
ASTUCES :
 
SUGERENCIAS:

39661000/39674000

Eurocube / Essence

  

2-Piece Dual Flush, Concealed Trapway Toilets, Low Flush 1.0 gpf/3.8 lpf, High Flush 1.28 gpf/4.8 lpf

2 pièce toilette, double affleurer, siphon masqué, Faible affleurer 1,0 gpc/3,8 lpc, Haute affleurer 1,28 gpc/4,8 lpc

Sifón oculto de doble descarga, inodoro de 2 pieza, Descarga baja 1,0 g/d 3,8 l/d, Descarga alta 1,28 g/d 4,8 l/c

Summary of Contents for Eurocube 39661000

Page 1: ...en these two positions the space for the supply between wall and toilet is limited to 3 In this case check your supply and hose dimensions REMARQUE La distance entre le mur et la ligne médiane de la collerette de la toilette doit être comme suit IMPORTANT L alimentation en eau doit être à 3 po ou 8 po de la ligne du centre de la toilette voir mesures fournies La première position suggérée est cach...

Page 2: ...upply between wall and toilet is limited to 3 In this case check your supply and hose dimensions REMARQUE La distance entre le mur et la ligne médiane de la collerette de la toilette doit être comme suit IMPORTANT L alimentation en eau doit être à 3 po ou 8 po de la ligne du centre de la toilette voir mesures fournies La première position suggérée est cachée derrière la toilette La géométrie de la...

Page 3: ...AQUETADURA DE GOMA TANK MTG BOLTS BOULONS DE MONTAGE DE RÉSERVOIR TORNILLOS DE MONTAJE DEL TANQUE WASHER NUT RONDELLE ET ÉCROU ARANDELA Y TUERCA RUBBER GROMMET RONDELLE CAOUTCHOUC ARANDELA DE GOMA AVERTISSEMENT IL N EST PAS NÉCESSAIRE DE TROP SERRER LES ÉCROUS POUR UN EMBOÎTEMENT PARFAIT PRECAUCIÓN NO APRIETE LAS TUERCAS MÁS DE LO NECESARIO PARA UN AJUSTE PRECISO 39661000 39674000 Eurocube Essence...

Page 4: ...TMENT AJUSTEMENT DU FLOTTEUR DE REMPLISSAGE AJUSTE DE FLOTACIÓN DE RECARGA 7 IMPORTANT Refill Float Adjustment If short flush does not refill the bowl turn thumb screw CCW 1 turn flush repeat if necessary Réglage du flotteur de emplissage Si la chasse à petit débit ne remplit pas la cuvette tourner la vis à oreilles dans le sens antihoraire de un tour évacuer et répéter si nécessaire Ajuste del fl...

Page 5: ...ttons approxi mately 1 2 12 mm Lightly snug Locking Nut Place Lid onTank Push Button to test flush If more stroke is needed loosen Locknut and turnThreaded Rod counterclockwise one 1 turn Replace Lid Repeat until flush action is achieved If Valve stays open turnThreaded Rod clockwise one 1 turn and lightly snug Locknut Care and Cleaning When cleaning your toilet wash it with mild soapy water rinse...

Page 6: ... sur le robinet de remplissage puis placez le robinet de remplissage vers le haut ou vers le bas au niveau d eau souhaité En cas d échec de siphonnage de la cuvette un réglage de la chaîne du robinet de chasse peut être nécessaire Retirez simplement la chaîne de son dispositif de retenue et tendez la avant de la replacer sur la tige de levage Assurez vous que la chaîne n est pas trop tendue Active...

Page 7: ... del tanque Ajuste de nivel de agua EUROCUBE Ajuste el nivel de agua levantando el interruptor de ajuste de nivel de agua a la posición ON en la válvula de llenado luego INSTRUCCIONES DE INSTALACIÓN suba o baje la válvula de llenado al nivel de agua deseado Fije la válvula de llenado bajando el interruptor a OFF Descargue el inodoro observando el nivel de agua Encienda el suministro de agua Verifi...

Page 8: ...ssence 2 Piece Dual Flush ConcealedTrapwayToilets Low Flush 1 0 gpf 3 8 lpf High Flush 1 28 gpf 4 8 lpf 2 pièce toilette double affleurer siphon masqué Faible affleurer 1 0 gpc 3 8 lpc Haute affleurer 1 28 gpc 4 8 lpc Sifón oculto de doble descarga inodoro de 2 pieza Descarga baja 1 0 g d 3 8 l d Descarga alta 1 28 g d 4 8 l c ...

Reviews: