4
Adjustment of economy stop on shower mixer 34 610,
see figs. [7] and [8].
•
The flow rate is limited by a stop, preadjusted by the
factory.
If a higher flow rate is desired, this stop can be
overridden by depressing the economy
button (J).
To adjust the stop, proceed as follows:
1. Unscrew and remove cap (K).
2. With a screwdriver, release the screw inside the shutoff
knob (L).
3. Turn the shutoff knob (L) until the desired flow rate is
obtained.
4. Pull off the shutoff knob (L) and reinstall in such a way
that point (M) on the scale coincides with the mark (O1)
on the inner part of the knob (O).
Testing the automatic diverter function on
mixer 34 472, see fig. [7].
Open the shutoff valve to release the water flow.
Initially, water flows from the bath spout.
Press diverter button
Transfer from bath
spout to shower outlet
Pull button
Transfer from shower
outlet to bath spout
Turning off the fitting automatically diverts the water flow
from the shower outlet to the bath spout.
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Maintenance
For maintenance, see Figs. [8], [9] and fold-out page II.
Shut off hot and cold water supplies.
I. For non-return valve, see fold-out page II
1. Disassemble mixer in reverse order, see fig. [1].
2. Remove dirt strainer (P2).
3. With a 12mm hexagon socket spanner, remove union
nipple (P) by turning clockwise (left-hand thread).
4. Remove non-return valve (P1).
II. For thermoelement, see Fig. [8] and
fold-out page II.
1. Turn thermostat knob (A) to 38
°
C stop.
2. Remove cap (B) and decorative ring (C).
3. Remove green guide ring (A1).
4. Pull off thermostat knob (A).
5. Remove clip (Z1).
6. Pull out stop ring (Z) until noticeable resistance is felt
(approx. 10 mm).
7. Unscrew and remove stop ring (Z) complete with
adjusting nut (F), see Fig. [10].
8. With a 24 mm open ended spanner, unscrew and
remove thermoelement (N).
Readjustment is necessary after every maintenance
operation on the thermoelement (see Adjustment).
III. Diverter, refer to Fig. [9].
1. Pull up bar (R) and use a screwdriver to lever out snap-
fit diverter button (S).
2. Unscrew nut (T) and detach remaining components (U).
3. Unscrew diverter (V).
IV. Ceramic headpart, refer to fold-out page II.
1. Remove cap (K) and decorative ring (K1).
2. Undo screw inside shut-off handle (L) and remove.
3. Remove screw assembly (W) and detach spray
holder (X) or handle base (Y).
4. Unscrew ceramic headpart (D) with 17 mm open-ended
spanner.
V. Unscrew and clean aerator (13 927), refer to fold-out
page II.
Inspect and clean all parts, replace if necessary and
grease with special valve grease (ref. No. 18 012).
Reassemble in the reverse order.
Use only genuine Grohe replacement parts.
Replacement parts, see fold-out page II (* = special
accessories).
Care
For directions on the care of this thermostat mixer, please
refer to the accompanying Care Instructions.
i976952.book : I97695GB.FM Seite 4 Freitag, Juli 23, 1999 10:31 AM
Summary of Contents for Chiara Series
Page 3: ...II 34 471 34 472 34 610 kl976952 fm Seite 3 Montag Oktober 11 1999 1 59 PM ...
Page 26: ...23 UAE i976952 book I97695UA FM Seite 23 Freitag Juli 23 1999 10 31 AM ...
Page 27: ...24 i976952 book I97695UA FM Seite 24 Freitag Juli 23 1999 10 31 AM ...
Page 38: ...35 RUS Ä 6 6 1 F R RSR F R RS i976952 book I97695RU FM Seite 35 Freitag Juli 23 1999 10 31 AM ...
Page 43: ...976952 book notizen fm Seite 40 Montag Oktober 11 1999 2 07 PM ...
Page 44: ...976952 book adresneu fm Seite 41 Montag Oktober 11 1999 2 07 PM ...