background image

4

English

Application 

Operation is possible in conjunction with:

- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters

Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications 

• Max. flow

8.3 L/min or 2.2 gpm / 60psi

• Flow pressure 

- min. 

7.25 psi

- recommended 

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

• Max. operating pressure

145 psi

• Test pressure 

232 psi

• Temperature

- max. (hot water inlet)

176 

°

F

• Water connection

cold - Right hand

hot - Left hand

Notes:

Major pressure differences between cold and hot water supply 
should be avoided.

Installation

Refer to the dimensional drawing on page 1.

Flush pipes thoroughly!

Side valves,

 see figs. [1] and [2].

Valve with a groove on the top edge of the cartridge (A) and 
in addition marked with blue tape should be mounted on the 
right (cold water) side.

Valve without a groove on the top edge of the cartridge (A) 
and in addition marked with red tape should be mounted on 
the left (hot water) side.

1. Screw the mounting set (B) to the bottom of the thread of the 

side valve (C), see fig. [1]. 
Make sure that the rubber washer (B1) is on the top of the 
fiber washer (B2).

2. Insert the side valve (C) through the basin hole from below.

3. Slide on seals (D) and screw on nut (E).

Make sure that the fiber washer (D1) is on the top of the 
rubber washer (D2).

4. With 32mm open-ended spanner fasten the side valve (C). 

The distance between the top of the cartridge and the basin 
must be 1 15/16", see fig. [2].

5. Screw the escutcheon (F) down to the side valve (C), see 

fig. [1].

6. Close the cartridges (clockwise for the hot side and counter-

clockwise for the cold side).

Mount lever (18 173) or handle (18 733), sold separately

,

 

see fig. [1].
1. Screw the ring (I) into the escutcheon (F) until tight. 

Hand tighten only!

2. Push on lever (G) or handle (H).
3. Tighten with screw (J) and screw in cover cap (J1).

It is recommended that the lever (G) be installed so they point 
away from the spout when in the off position.
If the gap between the handle and the escutcheon is 
excessive, back off the escutcheon (F) and the nut (E) to 
minimize the gap.

Spout,

 see fig. [3] to [5].

1. Place the O-ring (K) on the basin and insert the spout (L) 

from above, see fig. [3].

2. Place the gasket (M) against the bottom of the basin and 

fasten with the flange (N) and nut (O). Tighten nut (O) with 
a 13mm socket wrench.

3. Connect flexible hoses (P) from spout connection tee to the 

side valves, see figs. [4] and [5].

Mount lift rod and pop-up drain,

 see fig. [4].

1. Insert the lift rod (Q) through the spout and screw on the 

lower lift rod (R).

2. The connector is at the lower lift rod (R).
3. Fit pop-up drain (28 957), see page 2.

Ensure that flange of pop-up drain is sealed.

Connect wideset

Connect the side valves to the water supply. Insure the 
supplied washers are used for all connections.
The cold water supply should be connected on the right side 
valve (marked blue) and the hot water supply to the left valve 
(marked red).

Open cold and hot water supply and check connections 
for leakage!

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease.

Shut off cold and hot water supply!

I. Ceramic cartridge,

 see fig. [6].

1. Unscrew cover cap (J1) and screw out screw (J).
2. Pull off lever (G) or handle (H) and unscrew ring (I).
3. Unscrew escutcheon (F).
4. Unscrew ceramic cartridge (A) using a 17mm wrench.
5. Change complete ceramic cartridge (A).

Observe the different replacement part numbers of the 
cartridges,

 see page 2.

II. Laminar control,

 see page 2.

Unscrew and clean flow regulator (13 955).
Assemble in reverse order.

Replacement parts,

 see page 2 ( * = special accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Summary of Contents for Bridgeford 20 134

Page 1: ...English 1 Français 2 Español 3 Bridgeford Bridgeford 96 056 031 ÄM 205093 07 08 20 134 English 4 Français 6 Español 8 ...

Page 2: ...S v p remettre cette instruction à l utilisateur de la robinetterie Entregue estas instrucciones al usario final de la grifería Please pass these instructions on to the end user of the fitting 1 ...

Page 3: ...2 ...

Page 4: ...3 1 A B C D E F 24mm 32mm D1 D2 B1 B2 18 173 J H 32mm 18 733 G J1 J I I J1 2 6 F A J I 17mm I G H J J1 J1 3 13mm L K M N O 4 Q R P 19mm 5 ...

Page 5: ...w the ring I into the escutcheon F until tight Hand tighten only 2 Push on lever G or handle H 3 Tighten with screw J and screw in cover cap J1 It is recommended that the lever G be installed so they point away from the spout when in the off position If the gap between the handle and the escutcheon is excessive back off the escutcheon F and the nut E to minimize the gap Spout see fig 3 to 5 1 Plac...

Page 6: ...5 1 A B C D E F 24mm 32mm D1 D2 B1 B2 18 173 J H 32mm 18 733 G J1 J I I J1 2 6 F A J I 17mm I G H J J1 J1 4 Q R P 19mm 3 13mm L K M N O 5 ...

Page 7: ...F jusqu à ce que fortement Serrer seulement à la main 2 Poussez le levier G ou la poignée H 3 Serrez avec la vis J et vissez le capot J1 On lui recommande que le levier G soit installé ainsi eux se dirigent loin du bec quand dans la position de repos Si l intervalle entre le poignée et le rosace est excessif dégagez le rosace F et le bas l écrou E pour réduire au minimum l intervalle Bec voir fig ...

Page 8: ...7 1 A B C D E F 24mm 32mm D1 D2 B1 B2 18 173 J H 32mm 18 733 G J1 J I I J1 2 6 F A J I 17mm I G H J J1 J1 4 Q R P 19mm 3 13mm L K M N O 5 ...

Page 9: ... Apretarlo sólo con la mano 2 Empuje la palanca G o el pomo H 3 Apriete con el tornillo J y inserte la tapa de atornille J1 Se recomienda que la palanca G sea instalado tan ellos señala lejos del caño cuando en la posición de reposo Si el boquete entre la manija y el rosetón es excesivo retroceda el rosetón F y la tuerca E para reducir al mínimo el boquete Caño ver fig 3 a 5 1 Coloque la junta tor...

Page 10: ......

Page 11: ......

Page 12: ...ississauga Ontario Canada L5E 1E9 Technical Services Services Techniques Phone Tél 905 271 2929 Fax Télécopieur 905 271 9494 Grohe America Inc 241 Covington Drive Bloomingdale IL 60108 U S A Technical Services Phone 630 582 7711 Fax 630 582 7722 ...

Reviews: