background image

1

Safety notes

Prevent danger resulting from damaged voltage supply cables. 
If damaged, the voltage supply cable must be replaced by the 
manufacturer or his customer service department or an equally 
qualified person.

• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must 

not

 be directly or indirectly sprayed with 

water when cleaning.

• The voltage supply must be separately switchable.
• Use 

only genuine replacement parts and accessories

. The use of 

other parts will result in voiding of the warranty.

Application

For use with Listed Class 2 Power Supply or Limited Power Source Only.
Can be used in conjunction with:
• Pressurised storage heaters
Must 

not

 be used in conjunction with:

• Thermally controlled instantaneous water heaters
• Hydraulically controlled instantaneous water heaters
• Unpressurised storage heaters (displacement water heaters)

Operating conditions

The maximum permissible distance between the digital controller of the 
functional unit and the transceiver is 16.4 feet.

Sources of interferences

The transceiver operates in the ISM-frequency range (2.4 GHz). The 
installation in the vicinity of equipment with the same channel occupancy 
(eg wireless devices, RF components, etc. [observe the manufacturer´s 
documentation!]) should be avoided.

Obstructions/barriers

For operation under adverse environments, in buildings / rooms with 
reinforced concrete walls, steel and iron frame, or near of obstructions 
(eg furniture) of metal, the radio reception can be disturbed and 
interrupted.

Technical data

• Flow pressure:

- min:

0.1 MPa

- recommended:

0.2 - 0.5 MPa

• Operating pressure

max. 1.0 MPa

• Test pressure

1.6 MPa

If static pressure exceeds 0.5 MPa a pressure-reducing valve must be 
fitted.

Avoid major pressure differences between hot and cold water supply.
• Max. flow

4.8 L/min or 1.3 gpm / 0.41 MPa

• Hot water supply temperature:

min. 122 °F - max. 158 °F

- Recommended (energy saving):

140 °F

- Thermal disinfection possible

• Ambient temperature:

max. 104 °F

• Voltage supply:

120 V AC, 50/60 Hz

• Power consumption:

9 VA

• Radio frequency:

2.4332 GHz (channel 5-6)

• Transmitter power:

< 1 mW

• Emergency power supply:

6 V lithium battery (type CR P2)

• Digital controller battery:

3x 3 V lithium batteries (type CR 2450)

• Automatic safety shut-off (plant setting):

60 s

• Maximal temperature:

108 °F

• Type of protection:

- Faucet

IP 66

 

- Battery box

IP 59K

- Digital controller

IP X5

• Water connection:

cold - mark blue/warm - mark red

Electrical test data

• Software class:

B

• Contamination class:

2

• Rated surge voltage:

2500 V

• Temperature for ball impact test:

212 °F

The test for electromagnetic compatibility (interference emission test) was 
performed at the rated voltage and rated current.

Approval and conformity

This device complies with part 15 of the FCC Rules and with Industry 
Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired 
operation.
Changes or modifications not expressly approved by the party responsible 
for compliance could void the user’s authority to operate the equipment.

Electrical installation

Electrical installation work must only be performed by a 
qualified electrician and in accordance with National Electric 
Code and/or local requirements!

Installation

Install spout, 

see fold-out page II, Figs. [1] to [3].

Install functional unit,

 see Figs. [4] and [5].

Install pop-up waste,

 see Fig. [6]. Seal plug-hole rim!

Insert batteries into digital controller,

 see fold-out page III, Figs. [7] 

to [11]. 
Grease seals. Insert batteries with correct polarity.
The digital controller is registered with the functional unit by plant.

Secure digital controller,

 see Figs. [12a] or [12b] to [15].

Flush pipes thoroughly before and after installation. 

Connect functional unit,

 see fold-out page IV, Figs. [16] and [17].

Open hot and cold water supply and check connections for leakage.

Water flows until the voltage supply is established.

Connect battery housing to functional unit, 

see Fig. [18].

Establish voltage supply via plug-in voltage supply,

 see Fig. [19]. 

Approx. 10 seconds after the voltage supply is established there are two 
brief water pulses and the buttons of the digital controller are now 
inoperative for 60 seconds.

The reception can be improved using the transceiver special accessory 
(Prod. no. 36 356).

The functional unit must be adapted to the local conditions, see section 

Function menu of the digital controller, F2 - Setting mode

.

Settings in the event of a power failure/when changing batteries

No settings saved by the user will be lost when changing the batteries or 
in the event of an interruption of the voltage supply to the functional unit.

Kind of obstructions

Interference or shielding 
potential

Wood, synthetic material

Low

Water, brick, marble

Medium

Plaster, concrete, glass, solid wood

High

Metal

Very high

Bitte diese Anleitung an den Benutzer der Armatur weitergeben! / Please pass these instructions on 

Technische Änderungen vorbehalten! / The right to make technical modifications is reserved.

to the end user of the fitting.

Please pass these instructions on to the end user of the fitting.

The right to make technical modifications is reserved.

English

Summary of Contents for Allure F-digital 36 345

Page 1: ...UAE SK 4 8 11 18 22 29 39 43 53 57 60 SLO 64 71 BG EST LV LT 78 81 92 88 CN UA I 15 FIN 32 H 50 HR 67 RO 85 RUS 96 DESIGN ENGINEERING GROHE GERMANY www grohe com GROHE VERIS F DIGITAL 93 924 231 M 228...

Page 2: ...II I 2 32mm 1 3 5 4 6 36 345...

Page 3: ...III IV 8 20 7 22 24 1 2 9 14 13 15 16 16mm 17 21 10 11 12a 5 4 1 3 2 12b 5 40 19 16 3 16 25 2mm 1 2 3 18 19 1 2 36 356 max 2x 47 727 max 1x 65 815 23...

Page 4: ...ltage 2500 V Temperature for ball impact test 212 F The test for electromagnetic compatibility interference emission test was performed at the rated voltage and rated current Approval and conformity T...

Page 5: ...pressing and holding the buttons Start function F1 Automatic filling Confirm by simultaneously pressing the buttons Stop the water flow timer by turning the ring anti clockwise Continue the water flow...

Page 6: ...reen 1x Illuminated ring flashes green 1x Illuminated ring flashes green 3x Illuminated ring flashes green 1x Illuminated ring flashes green 3x Illuminated ring flashes violet 1x Button Description Vi...

Page 7: ...potential source of interference and check function again If positive reconfigure the interference source eg wireless router Rectify the fault see section Operating conditions 1x Batteries digital con...

Page 8: ...9K Contr leur num rique IP X5 Raccordement d eau froid rep re bleu chaud rep re rouge Donn es d essai lectriques Classe de logiciel B Degr de salissure 2 Tension nominale de choc 2500 V Temp rature de...

Page 9: ...ue Confirmation en appuyant simultan ment sur les touches Arr t du d bit mesureur du temps par rotation de l anneau dans le sens inverse des aiguilles d une montre Red marrage du d bit mesureur du tem...

Page 10: ...en vert L anneau lumineux clignote 1 fois en vert L anneau lumineux clignote 3 fois en vert L anneau lumineux clignote 1 fois en violet Touche Description Visualisation Activation du menu fonctions P...

Page 11: ...r r f 36 356 disponible comme accessoire sp cial D sactiver la source de perturbation potentielle et rev rifier le fonctionnement Si positif reconfigurer la source de perturbations par ex routeur Wi F...

Page 12: ...itio de 3 V tipo CR 2450 Desconexi n de seguridad autom tica ajuste de f brica 60 s Temperatura m xima 108 F Tipo de protecci n Grifer a IP 66 Caja de la bater a IP 59K Controlador digital IP X5 Acome...

Page 13: ...lujo de agua contador de tiempo girando el anillo en el sentido contrario a las agujas del reloj Prosiga el flujo de agua contador de tiempo girando el anillo en el sentido de las agujas del reloj Vue...

Page 14: ...veces en rojo El anillo luminoso parpadea 1 vez en verde El anillo luminoso parpadea 1 vez en verde El anillo luminoso parpadea 3 veces en verde El anillo luminoso parpadea 1 vez en verde El anillo lu...

Page 15: ...te de interferencias y volver a verificar la funci n Si existe una fuente de interferencias p ej un enrutador de LAN inal mbrica cambiar su configuraci n Eliminar las interferencias v ase el cap tulo...

Page 16: ......

Page 17: ......

Page 18: ...0 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3...

Reviews: