6
Fault/ cause/ remedy
Fault
Cause
Remedy
No flushing
• Water supply interrupted
- Open isolating valve in wall connection
box
• Filter in solenoid valve blocked
- Clean or replace filter,
see
Cleaning or replacing filter
• Plug-in connector without contact
- Attach plug-in connector
• The detection zone of the sensor system
is set too low/too high
- Increase/reduce detection zone using
remote control
(special accessories 36 407)
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
• Transformer faulty
- Replace transformer,
see
Replacing transformer
• Electronics defective (indicator
lamp not flashing or permanently on)
- Replace electronics,
see
Replacing the top plate
with electronics
Water flowing continuously
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Undesired flushing
• The detection zone of the sensor system
is set too high
- An opposite object will be detected.
Reduce detection zone using remote
control (special accessories 36 407).
Flow volume too low
• Flow volume set too low
- Adjust flow volume,
see
Setting the flow volume
• Filter in solenoid valve blocked
- Clean or replace filter,
see
Cleaning or replacing filter
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Flow volume too high
• Flow volume set too high
- Adjust flow volume,
see
Setting the flow volume
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Summary of Contents for 4005176211911
Page 37: ...34...
Page 38: ...35...
Page 39: ...36...
Page 42: ...39 36 407 36 407...
Page 66: ...63 36 407 36 407...
Page 81: ...78 36407 36 407...
Page 84: ...81 36 407 36 407...
Page 85: ...Grohe AG 37 749 X X X X X 1 28...
Page 86: ...III 19 E D F 20 E2 E E3 E4 18 F 1 2 17 G F 1 2 15 D1 D1 D 14 K 2 1 16 D E...
Page 87: ......