Grohe 39 141 Manual Download Page 6

3

GB

Applications

The radio receiver unit triggers flushing by using a radio 
transmitter.
Additionally, flushing can be triggered by manual actuation.
Manual actuation requires a WC cover plate for the pneumatic 
outlet valve (not included in the delivery specification).
For actuation via radio control, use radio transmitter order 
no. 38 758 or 39 142 + button (see replacement parts fold-out 
page I). As an alternative to GROHE radio transmitters, the 
product can also be used with radio transmitters made by 
Hewi, Keuco, Lehnen, Normbau, Pressalit, AMS, Deubad, 
Erlau FRELU and FSB.
Installation is an option with cistern GD2 with pneumatic outlet 
valve and filler valve on the left side, see fold-out page I 
Fig. [1].

Safety information

• Perform installation in frost-proof rooms only.
• Use only genuine replacement parts and accessories. Using 

other parts will void the warranty and CE marking.

Technical Data

• Voltage supply:

4 x 1,5 V battery, type LR-20

• Reception frequency:

868.4 MHz 

• Flow volume (3 - 6/9 l adjustable):

6 l

• Small flow volume:

3 l

(radio transmitters with 2 buttons only)

• Blocking time after a flushing:

5 s

• Automatic flushing (72 Hours):

Inactive

Approval and conformity

Conformity declarations can be obtained from the following 
address:

GROHE Deutschland Vertriebs GmbH

Zur Porta 9
D-32457 Porta Westfalica

Installation

Observe installation dimensions

, see Fig. [2].

New installation: Cut off inspection chamber flush with 
tiles

, see Fig. [3a].

Conversion: Dismantle actuation plate

, see Fig. [3b].

Prepare cistern

, see fold-out pages I and II, Figs. [4] to [6].

Replace existing hose with included hose with elbow

, see 

Fig. [7].

Attach lift rod to overflow pipe of outlet valve

, see Fig. [8].

Insert

 

batteries 

(not included in the delivery specification), 

see Fig. [9].

Making settings

, see chapter Making settings.

Install radio receiver unit,

 see Fig. [11] and [12].

Open water supply

, see Fig. [12].

Install actuation plate

, see Fig. [13].

Making settings

Registering a radio transmitter

A maximum of 30 radio transmitters may be registered.

When registering a radio transmitter, make sure that no other 
radio transmitters are being operated at the same time.

Deleting a radio transmitter

Set flow volume

This product conforms to the requirements of the 
relevant EU directives.

1.

Activate registration mode by pressing button (A), see 

Fig. [10].

Indicator lamp (B) displays:

██

  

2.

Within 30 seconds, press the transmitter button (C) for 

triggering flushing.

Indicator lamp displays:

██

   

██

   

██

  

The actuated radio transmitter is registered. Registration 

mode is terminated.

Further radio transmitters are registered as described above.

1.

Press and hold button (A), see Fig. [10].

Indicator lamp (B) displays:

██

  

______________________________

██

 

2.

Release button.

All registered radio transmitters have been deleted.

1.

Activate registration mode by pressing button (A), see 

Fig. [10].

Indicator lamp (B) displays:

██

  

2.

Repeat pressing and holding button (A).

Indicator lamp displays:

▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌

___

 

3.

When

___ 

appears,

 

release button.

Flow volume setting mode is activated. Flow volume is 

selected by pressing the button.

4.

Button pressed for the first time (within 2 seconds)

Indicator lamp displays:

██

   

██

   

██

Flow volume 3 l

Button pressed for the second time (within 2 seconds)

Indicator lamp displays:

██

   

██

   

██

   

██

Flow volume: 4 l

Button pressed for the third time (within 2 seconds)

Indicator lamp displays:

██

   

██

   

██

   

██

   

██

Flow volume: 5 l

Button pressed for the fourth time (within 2 seconds)

Indicator lamp displays:

██

   

██

   

██

   

██

   

██

   

██

Flow volume: 6 l

Button pressed for the fifth time (within 2 seconds)

Indicator lamp displays:

██

   

██

   

██

   

██

   

██

   

██

   

██

Flow volume: 9 l

After the group with 7 flashing signals, the routine starts 

from the beginning.

The flow volume is selected by refraining from pressing the 

button within 2 seconds after the desired flow volume is 

signalled. 

One flush is performed at the set volume with the signal 

flashing once more.

Summary of Contents for 39 141

Page 1: ...8 E 4 N 9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com 39 141 99 0414 031 M 232973 03 15 D 1 NL 11 PL 21 P 31 BG 41 CN 51 GB 3 S 13 UAE 23 TR 33 EST 43...

Page 2: ...ease pass these instructions on to the end user of the fitting S v p remettre cette instruction l utilisateur de la robinetterie Bitte diese Anleitung an den Benutzer der Armatur weitergeben 2 3a 4 5...

Page 3: ...II 7 9 C 38 758 B A C 39 142 10 1 2 12 8 13 11 1 2 14 1 2 15 6...

Page 4: ...laufventils befestigen siehe Abb 8 Batterien einsetzen nicht im Lieferumfang enthalten siehe Abb 9 Einstellungen vornehmen siehe Kapitel Einstellungen vornehmen Funkempfangseinheit einbauen siehe Abb...

Page 5: ...ollleuchte signalisiert Automatische Sp lung deaktiviert Jede Tasterbet tigung schaltet zwischen den beiden Zust nden um Die ausgew hlte Einstellung wird bernommen wenn innerhalb von 10 s nach einer S...

Page 6: ...ings Install radio receiver unit see Fig 11 and 12 Open water supply see Fig 12 Install actuation plate see Fig 13 Making settings Registering a radio transmitter A maximum of 30 radio transmitters ma...

Page 7: ...s stored if the button is not pressed again within 10 seconds of flushing Fault Cause Remedy Fault Cause Remedial action No flushing after the radio transmitter has been actuated Water supply interrup...

Page 8: ...ts de batterijen niet meegeleverd zie afb 9 Configureer de instellingen zie hoofdstuk Instellingen configureren Bouw de ontvangerunit voor de radiografische zender in zie afb 11 en 12 Open de watertoe...

Page 9: ...op wordt er naar de andere stand omgeschakeld Als de knop binnen 10 sec na het spoelen niet meer wordt ingedrukt wordt de gekozen instelling overgenomen Storing Oorzaak Oplossing Storing Oorzaak Oplos...

Page 10: ...ci gna na rurze przelewowej zob rys 8 Wk adanie baterii nie wchodz w zakres dostawy zob rys 9 Wprowadzanie ustawie zob rozdzia Wprowadzanie ustawie Monta modu u odbiornika radiowego zob rys 11 i 12 O...

Page 11: ...cza pomi dzy tymi dwoma stanami Wybrane ustawienie zostanie przej te je eli w ci gu 10 s po sp ukiwaniu nie nast pi naci ni cie przycisku Usterka przyczyna rodek zaradczy Usterka Przyczyna rodek zara...

Page 12: ......

Page 13: ......

Page 14: ...0 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3...

Reviews: