F211955R00
4
The signal lamp
The signal lamp is mounted in the field of vision of
the driver and out of direct sunlight, because of
the visibility of the signals. The lamp shows the
status of the greasing system and malfunction
reports by means of flashing codes. In the table
below, an overview of normal signals is given. For
malfunction signals refer to paragraph “The signal
lamp error flash codes” on page 5.
The signal lamp flash codes
Flash code
Moment
Significance
1 x 3 seconds on
5 seconds after switch-
ing on contact.
The supply voltage for the
control unit is available
and the signal lamp is OK.
After the additional
timer input switch
S1(P3) or S2(P7)
becomes active.
Only happens when the
para-meter lamp display
function has been set cor-
rectly.
Repeatedly: 1 x 0.3 se-
conds on, followed by a
pause of 2 seconds
After momentarily
pressing the test push-
button once.
A cycle test is being per-
formed via grease outlet 1.
Repeatedly: 2 x 0.3 se-
conds on, followed by a
pause of 2 seconds
After momentarily
pressing the test push-
button twice.
A cycle test is being per-
formed via grease outlet 2
(truck mode only).
Repeatedly: 3 x 0.3 se-
conds on, followed by a
pause of 2 seconds.
After momentarily
pressing the test push-
button three times.
A cycle test is being per-
formed via grease outlet 3
(truck mode only).
Continuously
When a pump cycle
was interrupted.
The maximum number of
attempts (parameter set
by an UniGINA) to perform
a grease cycle has been
reached.
When a fatal error is
detected.
Precisely which error
occurred can be deter-
mined by using an Uni-
GINA.
1 second on, 1 second
off continuously
When a low grease
level is detected.
Provided the parameter
settings have been set to
act this way.
0.5 second on, 0.5 se-
cond off continuously
When pump cycle is
executed.
Provided the parameter
settings have been set to
act this way.
GROENEVELD
976.01
USER
’S
INSTRUCTION
Summary of Contents for TriPlus Truck-3
Page 7: ......