background image

F211955R00

2

Automatic TriPlus Greasing System

This vehicle is equipped with a Groeneveld Automatic TriPlus Greasing System.

Featuring key

The TriPlus Greasing System will automatically and unconditionally grease all
connected grease points on a timely basis (cycle) with the correct quantity of
grease.

The system consists of

a grease pump with integrated control unit

progressive distribution blocks

a failure indicator lamp

an optional cycle mode switch with an integrated lamp

System performance

The system performs all operations automatically. After the ignition is switched
on or is in operation the pump will at pre-defined intervals supply measured
quantities of grease to all the points. Five seconds after the ignition is switched
on the signal lamp will light up for three seconds.

The test push-button

The test push-button on the pump unit has
three functions:

Performing a cycle test via one of the
grease outlet(s) of the pump unit.

Retrieving error messages stored in the
memory of the control unit.

Lamp reset after solving the error.

Performing a cycle test

A cycle test can be performed using the test push-button, as follows:
1.

The supply voltage for the pump unit must be available (ignition, brake 
lights or tail lights on).

2.

Push the test push-button (less than 1 second) 1, 2 or 3 times to perform a 
cycle test at outlet 1, 2 or 3 respectively. Provided that the preset delivery 
amount per outlet is more than 0cc.

3.

After two seconds the cycle test starts.

During the cycle test the signal lamp will flash at a particular frequency (see table
on page 4). The flashing frequency indicates at which outlet the cycle test is
being performed.
To end the cycle test immediately press the test push-button once.
Any errors that occur during the cycle test will not be indicated by the signal lamp
and will not be stored in the memory of the control unit.

USER

’S

 INSTRUCTION

Reviews: