BreakAlube-3
F600775R00
28
Maintenance
Automatic Greasing System
Release date: September 2014
Problem
Cause
Solution
The greasing point of the hy-
draulic hammer is too dry and a
malfunction is indicated.
Defective pump unit or block-
age in the system.
Retrieve the error code.
If the outlet blocked (relief valve
opened during a pump phase):
1. System contains grease that
is not suitable for the current
operating conditions.
Solution:
Replace the grease in the pump
and flush the system.
2. Grease hose or greasing point
blocked.
Solution:
Check if the quick coupler is
connected and fastened.
Check if the greasing point of
the hydraulic hammer is open
by means of a grease gun.
Check if the grease hoses are
damaged and/or blocked.
Other error codes:
Remedy the indicated malfunc-
tion.