Component description
Automatic Greasing System
Release date: September 2014
3.7
Signal lamp
GROENE
VELD
976.0
1
The signal lamp should be mounted in the field of vision of
the driver and out of direct sunlight, because of the visibili-
ty of the signals.
The lamp shows the status of the greasing system and mal-
functions reports by means of flashing codes. In the table
below, an overview of normal signals is given. For malfunc-
tion signals refer to the paragraph “Troubleshooting”.
3.7.1 The signal lamp flashing codes
Signal
Moment
Significance
Three seconds on
Five seconds after switching on
power (+15)
After activating the hammer,
option (parameter setting)
The supply voltage for the
control unit is available and the
signal lamp is OK
Input A (- or +) is available and
the control unit starts operation
Repeatedly: blink once followed
by a pause of two seconds
After momentarily pressing the
test push-button once
A cycle test is being performed
via grease outlet 1
Continuously
When allowed quantity of
grease is finished after reaching
minimum level
When maximum allowed num-
ber of errors in succession is
exceeded
Grease reservoir theoretical
empty
Serious system error
Continuously one second on,
one second off
When a minimum grease level
is detected
Provided the parameter settings
have been set to act this way
Continuously half a second on,
half a second off
When pump cycle is executed
Provided the parameter settings
have been set to act this way