Groen TDHC Series Operator'S Manual Download Page 3

OM-TDH/C

2

IMPORTANT — READ FIRST — IMPORTANT

WARNING:

FAILURE TO DISCONNECT POWER BEFORE SERVICING COULD RESULT IN
ELECTROCUTION AND DEATH.

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE  PROPERTY DAMAGE, INJURY OR DEATH.  READ THE INSTALLATION,
OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING
OR SERVICING THIS EQUIPMENT.

WARNING:

THE

 

UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH

ELECTRICITY AND PLUMBING.  UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.

WARNING:

DO NOT ATTACH THE UNIT TO A TYPE “B” VENT.  IT COULD CAUSE FIRE OR PROPERTY
DAMAGE.

WARNING:

DO NOT CONNECT ANY PIPING TO THE SAFETY VALVE.  IT MUST BE FREE TO VENT
STEAM  AS NEEDED. TO AVOID BURNS FROM THE VENTED STEAM THE VALVE
DISCHARGE SHOULD POINT DOWNWARD. 

DANGER:

ELECTRICALLY GROUND THE UNIT AT THE TERMINAL PROVIDED.  FAILURE TO
GROUND THE UNIT COULD RESULT IN ELECTROCUTION AND DEATH.

CAUTION:

BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL.

CAUTION:

DO NOT OVERFILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING.  KEEP
LIQUIDS A MINIMUM OF 2-3" (5-8 CM) BELOW THE KETTLE BODY RIM TO ALLOW
CLEARANCE FOR STIRRING, BOILING AND SAFE TRANSFER OF PRODUCT.

CAUTION:

KEEP FLOORS IN FRONT OF KETTLE WORK AREA CLEAN AND DRY.  IF SPILLS OCCUR,
CLEAN  IMMEDIATELY TO AVOID SLIPS OR FALLS.

WARNING:

KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND BURNERS.  NEVER SPRAY OR
HOSE DOWN THE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.

CAUTION:

MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES AND
CLOTHING.   TAKE PRECAUTIONS:  WEAR RUBBER GLOVES, GOGGLES OR FACE
SHIELD AND  PROTECTIVE CLOTHING.  CAREFULLY READ WARNINGS AND FOLLOW
DIRECTIONS ON CLEANER LABELS . 

WARNING:

DO NOT STAND ON OR APPLY UNNECESSARY WEIGHT OR PRESSURE ON THE KETTLE
FRONT OR POURING LIP. THIS COULD RESULT IN THE OVERLOAD AND FAILURE OF THE
TILT MECHANISM, AND POSSIBLE SERIOUS INJURY AND BURNS TO THE OPERATOR
AND OTHERS.

NOTICE:

NEVER LEAVE A SANITIZER IN CONTACT WITH STAINLESS STEEL SURFACES LONGER
THAN 10 MINUTES. LONGER CONTACT CAN CAUSE CORROSION.

WARNING

:

FAILURE TO PERIODICALLY CHECK SAFETY VALVE OPERATION COULD RESULT IN
PERSONAL INJURY  AND/OR DAMAGE TO EQUIPMENT.

WARNING:

WHEN TESTING, AVOID EXPOSURE TO THE STEAM BLOWING OUT OF THE SAFETY
VALVE.  DIRECT CONTACT COULD RESULT IN SEVERE BURNS.

WARNING:

TO AVOID INJURY,  READ AND FOLLOW ALL PRECAUTIONS STATED ON THE LABEL OF
THE WATER TREATMENT COMPOUND.

WARNING:

BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER
SUPPLY AND CLOSE THE MAIN GAS VALVE.  ALLOW FIVE MINUTES FOR GAS TO VENT.

CAUTION:

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR
AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO
THE EQUIPMENT AND WILL VOID  ALL WARRANTIES.

WARNING:

KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS. 
FAILURE TO DO SO  COULD RESULT IN FIRE OR PROPERTY DAMAGE.

CAUTION:

HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE SAFETY
VALVE.

Important:

Service Performed by Other than Factory Authorized Personnel Will Void All  Warranties.

Summary of Contents for TDHC Series

Page 1: ...DIAGRAM FOR First Choice Group Blakeney Way Kingswood Lakeside Cannock Staffs WS11 8LD TEL 01543 577778 FAX 01543504141 Email enquires firstchoice cs co uk Web www firstchoice cs co uk Steam Jacketed...

Page 2: ...T LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND...

Page 3: ...R HOSE DOWN THE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING TAKE PRECAUTIONS WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD A...

Page 4: ...OR WARNINGS 2 EQUIPMENT DESCRIPTION 4 INSPECTION UNPACKING 5 INSTALLATION INITIAL START UP 6 OPERATION 8 CLEANING 11 MAINTENANCE 12 SEQUENCE OF OPERATION 14 TROUBLESHOOTING 14 PARTS LISTS 16 SCHEMATIC...

Page 5: ...with electronic ignition Charged at the factory with chemically pure water containing rust inhibitors the steam source provides kettle temperatures of 150 F to approximately 295 F o The gas supply sh...

Page 6: ...lls shipping damage or shipment errors to the delivery When installation is to begin cut the straps holding the agent kettle on the skid and lift the kettle straight up off the CAUTION SHIPPING STRAPS...

Page 7: ...nce with the Canadian Electrical Code C S A C22 1 Part 1 and or local codes 5 The installation must conform with local codes or the American National Standards Z223 1 latest edition National Fuel Gas...

Page 8: ...SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL After the kettle has been installed the installer should test to ensure that it is operating correctly 1 Remove literature and packing materials from insid...

Page 9: ...ions WARNING KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS DO NOT ATTEMPT TO LIGHT ANY BURNER WITH A FLAME CAUTION HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE...

Page 10: ...THE KETTLE RIM TO ALLOW CLEARANCE FOR STIRRING BOILING PRODUCT AND SAFE TRANSFER WARNING WHEN TILTING KETTLE 1 WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON 2 USE DEEP CONTAINER TO CONTAIN AND MINIM...

Page 11: ...pasta shapes b Tips For Use 1 Allow for the water displacement of the basket and product to be cooked This may mean only filling the kettle half full of water Test the basket and product displacement...

Page 12: ...ucted by the supplier Clean the unit thoroughly A cloth moistened with cleaning solution can be used to clean controls housing electrical conduit etc d Rinse the kettle thoroughly with hot water Then...

Page 13: ...provided at the rear of this manual valve lever for about one second Repeat Each time service is performed on this Groen this step then let the valve lever snap equipment enter the date on which the w...

Page 14: ...ve open while you pour to let air escape from the jacket Continue adding water until the water level rises to the center of the round sight glass c Close the gate valve d Air that gets into the jacket...

Page 15: ...off cycling continues and Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if properly maintained However the following is a list of checks to make in the event of a p...

Page 16: ...lowing 1 Check the pilot gas line for kinks and obstructions Y 2 Clean orifice if necessary Y 3 Replace the pilot valve Y d That the pilot spark gap is 7 64 inch and located in the pilot gas stream If...

Page 17: ...OM TDH C 16 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage and phase...

Page 18: ...plate TDH 026450 58 Screw 1 4 20 x 3 4 hex ss TDH 40 005609 Cladding Panel TDH C 20 124758 35 Electrode Water Level 074623 Screw 1 4 20 x 1 1 2 hex ss TDH 20 005469 10 Spacer pedestal 128035 36 Switch...

Page 19: ...5 8 7 8 4 3 12 14 17 13 15 16 OM TDH C 18 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable...

Page 20: ...use Holder Type 3 AG 077854 11 Insert 8 screw nylon 124759 3 Control Water Level 115 V 097023 12 P C Board Mounting Post 099901 4 Transformer 50 VA 120 208 240 074839 13 Micro Switch 002982 5 Terminal...

Page 21: ...OM TDH C 20 Schematic...

Page 22: ...Serial No __________________________________ Location ____________________________________ Date Purchased _____________________________ Date Installed _______________________________ Purchase Order N...

Page 23: ...60 Battery March Park Quincy Massachusetts 02269 NFPA 54 Installation of Gas Appliances Gas Piping NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michig...

Page 24: ...al transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenance c...

Page 25: ...1055 Mendell Davis Drive OM TDH C Revised 4 99 Jackson MS 39272 Part Number 121049 Phone 601 372 3903 Fax 601 373 9587...

Reviews: