Groen TDHC Series Operator'S Manual Download Page 15

OM-TDH/C

14

Sequence of Operation

The following “action-reaction” outline is provided to

2.

High limit pressure switch, set to open at

help the user understand how  the equipment works.

about 43 PSI and shut down the burners

When the operator sets the desired temperature on
the thermostat dial, the thermostat switch closes and

3.

Pop safety valve, which will release steam

sends a signal which (1) starts the spark and (2)

if the jacket pressure exceeds ±50 PSI.

opens the automatic valve for the pilot burner. The
spark ignites the pilot flame, which heats a probe.

4.

Tilt switch that shuts off all burners when

The heated probe sends a signal that causes the

the kettle is tilted.

spark to shut off and the automatic valve to admit
gas to the main burner.  The pilot flame ignites the

When the kettle reaches the set temperature, the

main burner. If a pilot flame is not sensed within 30

thermostat switch opens, stopping the signal to the

seconds after the spark begins, a timer shuts down

gas control valve and causing the valve to shut off

the whole operation.  In addition to the lockout timer,

all gas flow. When the kettle cools below the set

safety features include:

temperature, the thermostat switch closes and starts

1.

Low water cutoff relay that will shut off the

maintains the kettle at the desired temperature.

gas supply to all burners until the water
level is corrected.

until jacket pressure is decreased.

another heating cycle. On-off cycling continues and

Troubleshooting

Your Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the following
is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel and
in this manual.

 If an item on the list is followed by 

Y

Y

, the work should be done by a qualified service

representative.

WARNING

BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY
AND CLOSE THE MAIN GAS VALVE.  ALLOW FIVE MINUTES FOR UNBURNED GAS TO VENT.

CAUTION

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR
AUTHORIZED DISTRIBUTOR CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE
EQUIPMENT AND WILL VOID ALL WARRANTIES..

SYMPTOM

WHO

WHAT TO CHECK

Y

Y

indicates items which must be performed by an authorized technician.

Kettle is hard to tilt.

Auth

a. Gears for foreign materials, lubrication and alignment. 

Y

Service
Rep Only

Kettle continues heating after User

a. Thermostat dial setting.

it reaches  desired
temperature.

Auth

b. Thermostat calibration.

Y

Service
Rep Only

c. Thermostat operation.  The thermostat should click when the dial is

rotated to settings above and below the temperature of the kettle.

Y

Kettle stops heating before it User

a. Thermostat dial setting.

reaches the desired
temperature.

Auth

b. Thermostat calibration.

Y

Service

c. Thermostat operation.  The thermostat should click when the dial is

Rep Only

rotated to settings above and below the temperature of the kettle.

Y

Safety Valve

 

pops open

User

a. For air in the jacket.  See “Jacket Vacuum” in the Maintenance

section.

b. Thermostat dial setting.

Summary of Contents for TDHC Series

Page 1: ...DIAGRAM FOR First Choice Group Blakeney Way Kingswood Lakeside Cannock Staffs WS11 8LD TEL 01543 577778 FAX 01543504141 Email enquires firstchoice cs co uk Web www firstchoice cs co uk Steam Jacketed...

Page 2: ...T LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND...

Page 3: ...R HOSE DOWN THE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING TAKE PRECAUTIONS WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD A...

Page 4: ...OR WARNINGS 2 EQUIPMENT DESCRIPTION 4 INSPECTION UNPACKING 5 INSTALLATION INITIAL START UP 6 OPERATION 8 CLEANING 11 MAINTENANCE 12 SEQUENCE OF OPERATION 14 TROUBLESHOOTING 14 PARTS LISTS 16 SCHEMATIC...

Page 5: ...with electronic ignition Charged at the factory with chemically pure water containing rust inhibitors the steam source provides kettle temperatures of 150 F to approximately 295 F o The gas supply sh...

Page 6: ...lls shipping damage or shipment errors to the delivery When installation is to begin cut the straps holding the agent kettle on the skid and lift the kettle straight up off the CAUTION SHIPPING STRAPS...

Page 7: ...nce with the Canadian Electrical Code C S A C22 1 Part 1 and or local codes 5 The installation must conform with local codes or the American National Standards Z223 1 latest edition National Fuel Gas...

Page 8: ...SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL After the kettle has been installed the installer should test to ensure that it is operating correctly 1 Remove literature and packing materials from insid...

Page 9: ...ions WARNING KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS DO NOT ATTEMPT TO LIGHT ANY BURNER WITH A FLAME CAUTION HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE...

Page 10: ...THE KETTLE RIM TO ALLOW CLEARANCE FOR STIRRING BOILING PRODUCT AND SAFE TRANSFER WARNING WHEN TILTING KETTLE 1 WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON 2 USE DEEP CONTAINER TO CONTAIN AND MINIM...

Page 11: ...pasta shapes b Tips For Use 1 Allow for the water displacement of the basket and product to be cooked This may mean only filling the kettle half full of water Test the basket and product displacement...

Page 12: ...ucted by the supplier Clean the unit thoroughly A cloth moistened with cleaning solution can be used to clean controls housing electrical conduit etc d Rinse the kettle thoroughly with hot water Then...

Page 13: ...provided at the rear of this manual valve lever for about one second Repeat Each time service is performed on this Groen this step then let the valve lever snap equipment enter the date on which the w...

Page 14: ...ve open while you pour to let air escape from the jacket Continue adding water until the water level rises to the center of the round sight glass c Close the gate valve d Air that gets into the jacket...

Page 15: ...off cycling continues and Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if properly maintained However the following is a list of checks to make in the event of a p...

Page 16: ...lowing 1 Check the pilot gas line for kinks and obstructions Y 2 Clean orifice if necessary Y 3 Replace the pilot valve Y d That the pilot spark gap is 7 64 inch and located in the pilot gas stream If...

Page 17: ...OM TDH C 16 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage and phase...

Page 18: ...plate TDH 026450 58 Screw 1 4 20 x 3 4 hex ss TDH 40 005609 Cladding Panel TDH C 20 124758 35 Electrode Water Level 074623 Screw 1 4 20 x 1 1 2 hex ss TDH 20 005469 10 Spacer pedestal 128035 36 Switch...

Page 19: ...5 8 7 8 4 3 12 14 17 13 15 16 OM TDH C 18 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable...

Page 20: ...use Holder Type 3 AG 077854 11 Insert 8 screw nylon 124759 3 Control Water Level 115 V 097023 12 P C Board Mounting Post 099901 4 Transformer 50 VA 120 208 240 074839 13 Micro Switch 002982 5 Terminal...

Page 21: ...OM TDH C 20 Schematic...

Page 22: ...Serial No __________________________________ Location ____________________________________ Date Purchased _____________________________ Date Installed _______________________________ Purchase Order N...

Page 23: ...60 Battery March Park Quincy Massachusetts 02269 NFPA 54 Installation of Gas Appliances Gas Piping NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michig...

Page 24: ...al transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenance c...

Page 25: ...1055 Mendell Davis Drive OM TDH C Revised 4 99 Jackson MS 39272 Part Number 121049 Phone 601 372 3903 Fax 601 373 9587...