background image

To order parts, contact your Groen Authorized Service Agent. Supply the model designation, serial 

number, part description, part number, quantity, and when applicable, voltage and phase.

PARTS LIST – SSB-3E/5E/1OEF

 Key  Description 

Part No.

1  Terminal Block 

070185

2  Capacitor, 3MF 

096813

3  Transformer 208/240v Primary/ 

121716

24v secondary, 75VA

4  Contactor 

145081

5  Fuseholder 

096809

6  Fuse 

119823

7  Ground Terminal (3E/5E) 

106412

Ground Terminal (10E) 

129714

8  Terminal Block (3E/5E) 

003888

Terminal Block (10E) 

002577

9  Water Valve 

071235

10  Muffin Fan 

153505

11  Drain Box (3E/5E) 

150659

Drain Box (10E) 

150661

12  Hi-Limit 

144484

13  Thermostat (drain box) 

145248

14  Drain Valve 

071234

 15A  Condensate Cup 

150628

 15B  Gasket, condensate cup 

142613

16  Ready Thermostat 

147285

17  Water Level Probe (Serial Number 

142689

MSA and MSB)

Float Probe (Serial Number 

149880

MSC and Following)

096857

160920

130858

125922

143874

160921

160648

119833

146880

160649

148553

148554

18  Door Switch 

19  Power Switch 

20  Door Assembly, Complete (3G) 

Door Assembly, Complete (5G) 

 Door Assembly, Complete (10G) 

21  Knob 

22  Control Board 

23  Tooroid (480V only) 

24  Motor Assembly 

25

 Relay Board 

26  Element 208v 1000w (3E/5E) 

 Element 240v 1000w (3E/5E) 

 Element 277v 1000w (3E/5E) 

148552

Element 208v 1000w (10E) 

148444

Element 240v 1000w (10E) 

148551

Element 277v 1000w (10E) 

148443

27  Top Panel (3E/5E) 

150637

Top Panel (10E) 

149444

 Key  Description 

Part No.

28  Front Panel Overlay (3E) 

153015

  Front Panel Overlay (5E/10E) 

153472

29  Door Latch Pin 

078914

30  Door Pin Lock Nut 

003823

31  Steam Lid (3E/5E) 

149299

  Steam Lid (10E) 

149452

32  Cavity Fan 

096790

33  Left Pan Rack (3E) 

149883

Left Pan Rack (5E) 

149872

  Left Pan Rack (10E) 

145642

34  Door Handle 

129723

35  Door Gasket (3E) 

124849

Door Gasket (5E) 

125907

Door Gasket (10E) 

143879

36  Terminal Block 480v Only (10E) 

003888

x  Motor Shaft Seal 

096868

x  Blower Cover (3E) 

149387

Blower Cover (5E) 

149313

Blower Cover (10E) 

149451

x  Right Pan Rack (3E) 

141571

Right Pan Rack (5E) 

140157

Right Pan Rack (10E) 

145721

x  Drip Tray (3E/5E) 

094151

Drip Tray (10E) 

145520

x  Left Side Panel (3E) 

149229

Left Side Panel (5E) 

149233

Left Side Panel (10E) 

149446

x  Right Side Panel (3E) 

149231

Right Side Panel (5E) 

149235

Right Side Panel (10E) 

149448

x  Flow Reducer, Condensate 

147371

x  Flow Reducer, Fill 

144481

x  Harness, Control To Relay 

160884

Board SSB

x  Harness, SSB Rear (3E/5E) 

160883

x  Harness, SSB Low Voltage (3E/5E) 

160880

x  Harness, SSB Foward (3E/5E) 

160882

x  Harness, Steamer High Voltage (3E/5E) 

160874

 

x  Harness, SSB High Voltage 

153486

x  Jumper, Voltage Select 

123124

x  Harness, SSB-10E Low Voltage 

153841

x  Harness, SSB-10E Forward 

153842

x  Harness, SSB-10E Rear 

153843

x  Harness, Steamer 480v only 

153118

x- Item not depicted/called out in drawing or photograph

20     OM-SSB-E

Summary of Contents for SMARTSTEAM100 2SSB-10E

Page 1: ...possibility of any damage including concealed dam age Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt It will be the responsibility of the consignee to file a claim with the carrier We recommend that you do so at once Manufacture Service Questions 888 994 7636 Information contained in this document is known to be current and accurate at the tim...

Page 2: ...AM CLEAN ANY PART OF THE UNIT WARNING ALLOW COOKING CHAMBER TO COOL COMPLETELY BEFORE CLEANING WARNING USE MILD CLEANING AGENTS ONLY CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF EACH CLEANING AGENT USE SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY CLEANING AGENT MANUFACTURER WARNING DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS STOPPED TURNING W...

Page 3: ...1 12 TROUBLESHOOTING 13 14 PARTS LIST 15 WIRING DIAGRAM 21 References UNDERWRITERS LABORATORIES INC NATIONAL FIRE PROTECTION ASSOCIATION 333 Pfingsten Road 60 Batterymarch Park Northbrook Illinois 60062 Quincy Massachusetts 02269 NFPA 70 The National Electrical Code SERVICE LOG 23 WARRANTY PROTECTION 24 NSF INTERNATIONAL 789 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48113 0140 OM SSB E 3 ...

Page 4: ...he carton from the skid Pull the carton up off the unit Be careful to avoid personal injury or equipment damage from staples which might be left in the carton walls Write down the model number serial number and installation date Keep this information for reference Space for these entries is provided at the top of the Service Log in the back of this manual The drain system on all models includes a ...

Page 5: ...g power is located at the back of the control compartment The ground terminal is located in the wiring compartment near the terminal block E Supply Wire The equipment grounding wire must comply with the National Electrical Code NEC requirements The wiring diagram on the inside of the unit s right side cover gives directions for proper connection of the terminal block jumpers The wire must be used ...

Page 6: ...Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA 4 Drain Connection Level the steamer front to back and pitch it slightly to the front maximum 1 4 inch by adjusting the optional legs or the bullet feet on the optional stand WARNING DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN BLOCKING THE DRAIN IS HAZARD...

Page 7: ... supply connection is used for both units At the water inlet valve a 3 4 inch female NH connector gardenhosetype isusedforthewatersupply B Electrical Supply Connection Separate electrical connections will be requiredforeachsteamertobestacked Each steamer unit must have it s own branch circuit protection C Drain Connection Steamers must be leveled front to back and pitched to the rear maximum 1 4 i...

Page 8: ...the steam generating reservoir has filled with water the heaters will begin heating automatically Within 20 minutes or less the READY light will come on indicating that the water has reached its standby temperature When the READY light is displayed you may take any one of the following steps a Push TIMED and set the timer knob to the desired steaming time b Push MANUAL for continuous steaming c Pus...

Page 9: ...e the steam generator stays at a low boil or ready temperature 3 When the MANUAL button is pushed the unit steams continuously The MANUAL light will stay illuminated 4 CANCEL button should be pushed to stop beeping TIME display TIMER knob MANUAL button and indicator TIMED button and indicator STOP button and indicator CANCEL button and indicator FAULT display ON OFF rocker switch Hour meter READY ...

Page 10: ...ant to steam continuously push the MANUAL button The unit will continue steaming until stopped Push STOP to stop producing steam To remove pans from cavity open the door Remove the pans from the steamer using hot pads or oven mitts to protect your hands from the hot pans 2 3 4 5 WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT THE STEAM CAN CAUSE BURNS 6 To shut off t...

Page 11: ...ing must be done in order to enhance the performance and prolong the life of your SmartSteam Boilerless Steamer IMPORTANT DO NOT USE ANY METAL MATERIAL SUCH AS METAL SPONGES OR METAL IMPLEMENTS SUCH AS A SPOON SCRAPER OR WIRE BRUSH THAT MIGHT SCRATCH ANY STAINLESS STEEL SURFACE SCRATCHES MAKE THE SURFACE HARD TO CLEAN AND PROVIDE PLACES FOR BACTERIA TO GROW DO NOT USE STEEL WOOL WHICH MAY LEAVE PA...

Page 12: ...r to deliming instructions below S STEP 8 Remove drain strainer and clean thoroughly to remove any build up of debris TEP 9 Replace pan racks and steam lid Steamer is now cleaned and ready to use DELIMING INSTRUCTIONS When using Groen Boilerless Water Filtration System use vinegar as a deliming agent Groen approved delimer may be used to remove excessive scale build up STEP 1 After following all c...

Page 13: ...n steamer s during normal operation 2 No power User a Check wall circuit breaker b Disconnect power then check fuses inside steamer c Call service technician c Call service technician 3 Unit overfills with User a Clean floats in unit Check float probe orientation water at start up b Clean drain strainer 4 Steamer does not fill User a Is the ON switch depressed with water b Is the water supply connect...

Page 14: ...unit back on 9 Door pops open User a Ensure drain and vent are not plugged No more than two units should be attached to a single drain line b Check door pin adjustment per above c Call service technician 10 Fault Display 6 User a Wait 30 minutes for unit to cool down b Call service technician OM SSB 3E 5E 10EF 14 OM SSB E ...

Page 15: ...PARTS LIST SSB 3E 5E 1OEF OM SSB E 15 ...

Page 16: ...PARTS LIST SSB 3E 5E 1OEF 16 OM SSB E ...

Page 17: ...PARTS LIST SSB 3E 5E 1OEF OM SSB E 17 ...

Page 18: ...PARTS LIST SSB 3E 5E 1OEF 18 OM SSB E ...

Page 19: ...PARTS LIST SSB 3E 5E 1OEF OM SSB E 19 ...

Page 20: ... 28 Front Panel Overlay 3E 153015 Front Panel Overlay 5E 10E 153472 29 Door Latch Pin 078914 30 Door Pin Lock Nut 003823 31 Steam Lid 3E 5E 149299 Steam Lid 10E 149452 32 Cavity Fan 096790 33 Left Pan Rack 3E 149883 Left Pan Rack 5E 149872 Left Pan Rack 10E 145642 34 Door Handle 129723 35 Door Gasket 3E 124849 Door Gasket 5E 125907 Door Gasket 10E 143879 36 Terminal Block 480v Only 10E 003888 x Mo...

Page 21: ...WIRING DIAGRAM SSB 3E 5E 1OEF OM SSB E 21 ...

Page 22: ...WIRING DIAGRAM SSB 3E 5E 1OEF 22 OM SSB E ...

Page 23: ..._____________ Purchased From ______________________ Serial No ___________________________ Location _____________________________ Date Purchased_______________________ Date Installed_________________________ Purchase Order No ____________________ For Service Call _______________________ OM SSB E 23 ...

Page 24: ...stalled a Groen PureSteem Water Treatment System for use in connection with such Groen Convection Combo Steamer Oven HyPerSteam Convection Steamer or HyPlus Pressureless Steamer on or before teh date such Groen Equipment was installed b the original purchaser user has continuously used such Water Treatment System in connection with such Groen Equipment from the date of installation and c the comme...

Page 25: ...ed Extended Warranty Coverage is available on all standard Groen Equipment other than CapKold foodservice equipment covered by the above Groen Limited Warranty Commercial purchasers users of Groen Equipment may elect to extend the standard limited warranty to cover parts labor and portal to portal transportation costs time and mileage for an additional i 2000 actual operating hours or ii twelve 12...

Page 26: ...NOTES 26 OM SSB E ...

Page 27: ...NOTES OM SSB E 27 ...

Page 28: ...1055 Mendell Davis Drive s Jackson MS 39272 888 994 7636 s 601 372 3903 s Fax 888 864 7636 groen com PART NUMBER 145145 REV L 1 10 ...

Reviews: