Installation and Start-Up
WARNING
THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY
AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO
THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.
CAUTION
DO NOT INSTALL WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 12 INCHES OF A HEAT SOURCE
(BRAISING PAN, DEEP FRYER, CHAR BROILER, OR KETTLE).
TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK.
HY-12GF
UTILITY CONNECTIONS:
1. Electrical connection ½” (13 mm) conduit fitting.
2. Cold water supply connection ¾” (19 mm) hose
3. Drain connection 2½” (64 mm) hose connection
4. Gas connection ¾” (19 mm) NPT
HY-24GF
UTILITY CONNECTIONS:
1. Electrical connections
(each cavity) ½” (13 mm)
conduit fitting.
2. Cold water supply connection
(each cavity) ¾” (19
mm) hose
3. Drain connection 2½” (64 mm) hose connection
4. Gas connection
(each cavity) ¾” (19 mm) NPT
BURNER FIRING RATES PER CAVITY
ELECTRICAL SPECIFICATIONS
Natural Gas @ 3.1" WC
L.P. Gas at 10" WC
Voltage: 108-126V 1 Phase 50/60 Hz
BTU/hr HY-12G
160,000
150,000
Current per cavity 2.5 AMPS ± 10%