background image

OM-CC-E

22

2.

Interior Cleaning

To exit the Clean Cycle at any time, press and
hold the 

CLEAR

 touch pad.  

Be sure to wash

out all chemical residues thoroughly before
using the unit.

WARNING

UNIT MAY BE HOT.  DO NOT TOUCH HOT
SURFACES.

DO NOT PUT  HANDS OR OTHER OBJECTS
INTO COOKING CHAMBER WHILE CONVECTION
COMBO™ IS OPERATING.  THE ROTATING FAN
CAN BE HAZARDOUS.

a.

Turn off all operating modes by stopping the
timer, and pressing the mode touch pad(s).

b.

Enter 99 on the timer.  The display should
show “00:99.”

c.

If the 

HOT

 light is on, use the Fast Cool

method to reduce the temperature
(Paragraph 5, Operation, Page 18).  If the

HOT

 light is off, “CI” will be displayed in the

timer window, and you may proceed to the
next step.

d.

Remove all pan racks and clean them in a
sink.  To remove the right side rack, lift it up
and to the left.

e.

Remove the right side of the cooking
chamber.

f.

Prepare oven degreaser as directed on the
product label.  Thoroughly coat all inside
surfaces of the cooking chamber and both
sides of the right side panel with the
degreaser.

g.

Remove the steam generator cover.

NOTE:

Add degreaser to the steam generator

only if you see grease deposits.

h.

If there are grease deposits in the generator,
add ¼ to ½ cup (60 to 125 ml) of full
strength degreaser to the generator, or
lightly coat the generator with spray
degreaser. Do not use too much degreaser. 

It may cause the unit to display false service
messages.

i.

Replace the generator cover and right side
panel in their normal positions.

j.

Close the door and press 

START

.  The timer

will display “CL:50,” with the colon [:]
between the numbers flashing.  The timer will
count down to “CL:26.”

k.

When the buzzer sounds and the timer
displays “C2,” open the door.

WARNING

THE UNIT WILL BE HOT ENOUGH TO CAUSE A
BURN.  DO NOT TOUCH ANY HOT SURFACE.

l.

Remove the right side panel and steam
generator cover and rinse them in the sink.

l.

Rinse and wipe down the cooking chamber
with a cloth and plenty of clean water.  Rinse
the cloth often.

n.

Add de-liming agent to the steam generator
as specified by the de-liming agent label.

o.

Put the generator cover and right side panel
back in place.

p.

Close the door.  The timer will display
“CL:26" and count down automatically to
“CL:00.”

q.

Press the 

ON

 switch to turn off the unit.  Let

the unit cool.

WARNING

UNIT MAY BE HOT.  DO NOT TOUCH HOT
SURFACES.

r.

Remove the right side panel and steam
generator cover and rinse them thoroughly in
a sink.

Summary of Contents for CC20-EF

Page 1: ...ECTION COMBO Combination Steamer Oven THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL FOR YOUR SAFETY DO NOT STORE O...

Page 2: ...THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLO...

Page 3: ...TROUBLESHOOTING 25 SERVICE LOG 30 WARRANTY PROTECTION 31 References UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Min...

Page 4: ...the cabinet at a thickness of 1 to 2 inches 4 to 5 cm A removable drip tray is located beneath the door Door hinges are reversible so that doors may open from the left or right side Operator controls...

Page 5: ...your water The water going to the steam generator should have between 30 and 40 parts per million ppm total dissolved solids TDS and should have a pH acidity rating of 7 0 to 9 0 Please follow these s...

Page 6: ...ove the two screws at the bottom of the panel Slide the panel toward the front of the unit lift it and set it aside b Supply Voltage The CC10 E must operate at the rated nameplate voltage plus or minu...

Page 7: ...r each steam generator must be able to fill the generator with 1 gallons 5 7 liters or water in 1 minutes The make up water rate is 0 06 gallons per minute 0 2 liters per minute Condensate spray water...

Page 8: ...OM CC E 8 Proper Drain Line Connections...

Page 9: ...ground wire must be at least 8 AWG 3 3 mm for a 100 amp circuit breaker or 10 AWG 2 6 mm for a 40 to 60 amp breaker d Supply Wire The type of wire needed is determined by finding the operating voltage...

Page 10: ...THE DRAIN IS HAZARDOUS IMPORTANT Do not allow any water traps in the line A trap can cause pressure to build up inside the cavity during steaming which will make the door gasket leak NOTE Improper dra...

Page 11: ...62 13 14000 4267 14 15000 4572 15 5 For CC20 E only Check Fan Rotation IMPORTANT As seen from inside the oven cavity the fan should be turning in a counterclockwise direction If the fan is running bac...

Page 12: ...ature is attained the WAIT light will go off and the READY light will come on NOTE The timer does not control the oven in either the Combo or Oven Modes 9 To Test Oven Mode Operation turn on the power...

Page 13: ...display of 01 30 On some older units numbers higher than 59 will not be accepted in these cases convert the time to hours and minutes 90 minutes would be entered 1 3 0 b Time touch pads used to enter...

Page 14: ...MP Section a The Temperature Display Window shows the selected temperature in either Oven or Combo Mode It is blank in the Steamer Mode or when the optional Hold Mode is operational b Turning the Temp...

Page 15: ...was recently used in Oven or Combo Mode the HOT light may come on indicating that the cooking chamber is too hot for use as a steamer The unit can be cooled quickly to the steaming temperature range b...

Page 16: ...pressing CLEAR twice A new cooking time may then be set by using the number keys 2 Oven Mode a To use the Convection Combo as a convection oven first switch on the electric power by pushing the ON to...

Page 17: ...oking take the pans out of the oven using hot pads or oven mitts to protect your hands from the hot pans The unit will continue heating to keep the chamber at the set temperature until the temperature...

Page 18: ...splay and enter the time again The timer does not control the unit in Combo Mode h Load the food into the pan or pans in a uniform layer WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM ANY STEAM COMING...

Page 19: ...e timer will now count UP The COOK temperature display will be blank and the temperature of the unit will slowly drop to the HOLD temperature setting NOTE Food will continue to be cooked by the excess...

Page 20: ...n operates with the door open WARNING DO NOT PUT HANDS OR OTHER OBJECTS INTO THE COOKING CHAMBER DURING THE FAST COOL OPERATION THE ROTATING FAN CAN BE HAZARDOUS b To stop the Fast Cool operation pres...

Page 21: ...olution c Stainless steel surfaces may be polished with a recognized stainless steel cleaner such as Zepper PRECAUTIONS WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE UNIT KEEP...

Page 22: ...e steam generator only if you see grease deposits h If there are grease deposits in the generator add to cup 60 to 125 ml of full strength degreaser to the generator or lightly coat the generator with...

Page 23: ...door The timer will display CL 26 and count down automatically to CL 00 k Press the ON switch to turn off the unit Let the unit cool WARNING UNIT MAY BE HOT DO NOT TOUCH HOT SURFACES l Remove the righ...

Page 24: ...and turn the latch pin turn clockwise Re tighten the lock nut b After adjustment run the unit to test for further steam leaks c If there is still leakage repeat the adjustment d Continue adjusting the...

Page 25: ...rate in Oven Mode only Call your Groen Service Agency 7 Out of Calibration Units Before 3 97 Only The unit will operate in all modes Call your Groen Service Agency 7A Time Between Fills Units After 3...

Page 26: ...OM CC E 26 CC10 E Heater Schematic CC10 E Control Schematic Diagrams Schematics...

Page 27: ...OM CC E 27 CC20 E Control Schematic 480 Volts CC20 E Control Schematic 208 240 Volts Diagrams Schematics Continued...

Page 28: ...OM CC E 28 CC20 E Heater Schematic 208 240 Volts CC20 E Heater Schematic 480 Volts Diagrams Schematics Continued...

Page 29: ...OM CC E 29 CC20 E Heater Schematic 208 240 Volts Units That Meet Canadian Standards Association Requirements Diagrams Schematics Continued...

Page 30: ...OM CC E 30 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Page 31: ...tal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boile...

Page 32: ...1055 Mendell Davis Drive OM CC E Revised 7 00 Jackson MS 39212 Part Number 121015 Rev A Telephone 601 372 3903 Fax 601 373 9587...

Reviews: