background image

 

GRN Batten 3-54 v5.4 

GRN

lite.com 

 

Data Input  

 
 

The fixture uses standard DMX and has a 3-pin XLR for DMX data input and thru. 

 
 

The Data connections for 3 pin XLR are as follows:  

 

 

Pin 1   =  

GND/Shield 

 

Pin 2   =  

Data (-) 

 

Pin 3   =  

Data (+) 

 

 

 

Adapting a 5-pin XLR data feed to 3-pin XLR is as follows: 

 

 

5-pin XLR 

 

3-pin XLR 

     

   Pin 1   

    Pin 1 

    

   Pin 2    

    Pin 2 

    

   Pin 3   

    Pin 3 

     

   Pin 4   

    N/C 

    

   Pin 5    

    N/C 

Page 4 

Summary of Contents for Batten 3-54

Page 1: ...GRN Batten 3 54 v5 4 GRNlite com GRN Batten 3 54 User Manual v5 4...

Page 2: ...1 About the GRN Batten 3 54 2 Power input and Voltage adjustment 3 Data input 4 Fixture Placement Hanging Maintenance 5 Fixture Menu Options 6 Cell Configuration for DMX Channel Modes 7 DMX Channel Mo...

Page 3: ...ation which can damage the retina permanently Use extreme caution when servicing the fixture or when in close proximity to the powered fixture Never look directly into the front of the fixture when it...

Page 4: ...gives a multitude of advantages unique to LED technology The RGBAW LEDs give a much wider color gamut than the usual RGB systems and with dramatically increased power efficiency over older technologie...

Page 5: ...must be replaced with the proper type and rating Page 3 Open the bottom of the fixture to expose the Power supply Remove Yoke Remove 4 screws on plastic end caps Remove 6 screws on bottom cover plate...

Page 6: ...d has a 3 pin XLR for DMX data input and thru The Data connections for 3 pin XLR are as follows Pin 1 GND Shield Pin 2 Data Pin 3 Data Adapting a 5 pin XLR data feed to 3 pin XLR is as follows 5 pin X...

Page 7: ...the clutch handle clockwise to retighten A safety cable should be used for every fixture other than those that use ground support NOTE The GRN Batten fixtures may be mounted in any orientation as lon...

Page 8: ...ot active in any other mode of operation Page 6 Mode Function Run Mode DMX on off Slav ON Off FADE Mode Preprogrammed single fade chase Speed adjustable only FLOW Mode Preprogrammed flow chases 0 9 ad...

Page 9: ...N Batten 3 54 v5 4 GRNlite com Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 The GRN Batten 3 54 has 6 cells that can be addressed individually or in various groups GRN Batten 3 54 cell configuration Page...

Page 10: ...Description 1 Red 0 255 Proportional All Cells 2 Green 0 255 Proportional All Cells 3 Blue 0 255 Proportional All Cells 4 Amber 0 255 Proportional All Cells 5 All Cells White 0 255 Proportional 6 All...

Page 11: ...Cells 4 5 6 Green 0 255 Proportional 8 Cells 4 5 6 Blue 0 255 Proportional 9 Amber 0 255 Proportional Cells 4 5 6 10 Cells 4 5 6 White 0 255 Proportional 11 All Cells Macro Sets a default look 12 All...

Page 12: ...Cells 1 2 White 0 255 Proportional 6 Cells 3 4 Red 0 255 Proportional 7 Cells 3 4 Green 0 255 Proportional 8 Cells 3 4 Blue 0 255 Proportional 9 Amber 0 255 Proportional Cells 3 4 10 Cells 3 4 White...

Page 13: ...n 0 255 Proportional 13 Cell 3 Blue 0 255 Proportional 14 Cell 3 Amber 0 255 Proportional 15 Cell 3 White 0 255 Proportional 16 Cell 4 Red 0 255 Proportional 17 Cell 4 Green 0 255 Proportional 18 Cell...

Page 14: ...r Neutrik Powercon 20A in and through Operating Current 1 8A 208V 60Hz 2 3A 110V 60Hz Mains Fuse 4A 250V Weight 16 5 lbs 7 5 kgs Dimensions 24 L x 8 25 W x 4 H 609 mm x 210mm x 104mm Output 5750 Lux 1...