-14-
Model T32339 (Mfd. Since 03/21)
6. Remove power supply wires from LINE termi-
nals and ground wire shown in
Figure 12 to
remove 5-15 plug.
Figure 12. Location of wires to remove.
7. Connect (2) 6-15 plug power supply wires to
LINE terminals, and ground wire to ground
terminal (see
Figure 13).
Make sure incoming ground wire is
connected to correct terminal to ensure
machine will be properly grounded (see
"Ground Terminal" in Figure 13). An
ungrounded or improperly grounded
machine can cause electrocution if live
electrical wires make contact with frame or
other parts touched by operator.
Figure 11. Location of pressure switch cover
and screw.
5. Remove screw shown in Figure 11 to remove
pressure switch cover.
LINE
MOTOR
LEFOO LF10-4H
PRESSURE
SWITCH
GND
Neutral
Hot
Ground
115 VAC
5-15 Plug
MOTOR 115V/230V
Run
Capacitor
30uF 370V
Start
Capacitor
189-227uF 165V
1
4
2
6
Ground Wire
Power
Supply
Wires
Figure 13. 6-15 plug installed.
6-15 Plug
Hot
Hot
Ground
230
VAC
G
LINE
MOTOR
LEFOO LF10-4H
PRESSURE
SWITCH
GND
MOTOR 115V/230V
Run
Capacitor
30uF 370V
Start
Capacitor
189-227uF 165V
(As Recommended)
1
4
2
6
8. Install pressure switch cover.
Ground
Terminal
Power
Supply
Wires
Ground Wire
Pressure Switch
Cover
Summary of Contents for T32339
Page 48: ......