Model T28929 (Mfd. Since 11/18)
-3-
Drill Press Operations
To use the Model T28929 with a drill press, the
notcher must be clamped securely to the drill
press base. It is important that the notcher is
secure enough so it will not twist or come off
of the table during use. To ensure square cuts,
the jig must be square to the base before being
mounted to the drill press table.
3. Place notcher on drill press work table and
adjust table until top of notcher spindle is
1
⁄
2
"
lower than drill chuck (see
Figure 9).
Items Needed
Qty
Open-End or Socket Wrench 13mm ................. 1
Hole Saw with
1
⁄
2
" or
5
⁄
8
" Threads ...................... 1
Drill Press w/14" Between Chuck and Table ..... 1
Open-End or Socket Wrench 17mm .................. 2
Base-Fastening Hardware ................. As Needed
Cutting Fluid ...................................... As Needed
Failure to align spindle flats properly with
chuck jaws may result in spindle coming
loose and damaging notcher and drill chuck.
To reduce risk of eye or face injury from
flying chips, always wear approved safety
glasses and a face shield when operating
drill press.
4. Loosen two hex bolts from Step 2 just enough
so notcher can be aligned with drill chuck.
5. Open drill chuck jaws and use downfeed
handles to lower chuck onto notcher spindle,
aligning chuck jaws with flats of notcher
spindle (see
Figure 10). Tighten chuck jaws
to secure.
2. Loosen both hex bolts in Figure 8, then swiv-
el base until square to frame, then tighten hex
bolts.
Figure 8. Base squared to frame.
Hex Bolts
Base
To operate notcher with drill press:
1. Install hole saw and workpiece on notcher.
Figure 10. Chuck attached to spindle.
Spindle
Chuck
Figure 9. Table adjusted correctly.
Notcher Spindle
Drill Press
Chuck
6. Adjust base of notcher until it is flat to drill
press table, then tighten hex bolts from
Step 2.
Summary of Contents for T28929