background image

Model T10009  5000 Kg Digital Crane Scale

-4

-

Your  crane  scale  was  carefully  packaged 
for safe shipping. If you discover any dam-
age  after  you  have  signed  for  delivery, 

immediately call Customer Service at (570) 
546-9663

 

for advice. 

Save the containers and all packing materi-
als for possible inspection by the carrier or 
its  agent. 

Otherwise,  filing  a  freight  claim 

can be difficult.

When  you  are  completely  satisfied  with 
the  condition  of  the  shipment,  you  should 
inventory the contents.

SECTION 3: SET UP

Unpacking

Figure 1.

 Model T10009 inventory

A

Model T10009 Inventory (Figure 1)
A.

   Crane Scale ....................................... 1

B.

   Scale Battery Charger ....................... 1

C.

  Remote Control .................................. 1

Inventory

B

C

Site Consideration

Weight Capacity

 

The Model T10009 crane scale has a max-
imum  capacity  of  5,000  Kg  (11,026  lbs.). 
When choosing a mounting site, verify that 
the lifting structure can withstand at least 
the maximum loading capacity as well as 
any possible overloading that may occur.

Working Clearances

Consider  existing  and  anticipated  needs, 
dimensions of your weighing platform, size 
of  material  to  be  weighed,  and  whether 
you  need  the  scale  to  be  mobile  or  in  a 
stationary  location  when  establishing  an 
installation  site  for  your  crane  scale.  For 
an accurate reading, there must not be any 
items near the scale or weighing platform 
that may lean or fall and add weight. 

Power Outlets

The Model T10009 crane scale includes a 
remote control and scale battery charger. 
When  establishing  a  site  for  your  scale, 
make  sure  outlets  are  located  near  the 
scale  so  power  or  extension  cords  are 
clear of high-traffic areas.

Do  not  place  the  crane  scale  in  areas  of 
high  electrical  fields.  Electrical  fields  can 
effect scale accuracy. 

No  list  of  safety  guidelines  is  complete,  because  every  work  environment  is 
different. Always consider safety first and use common sense. Failure to use this 
tool with caution and respect could result in serious personal injury.

Summary of Contents for T10009

Page 1: ...ZZLY INDUSTRIAL INC WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC JM10065 PRINTED IN CHINA MODEL T10009 5000 Kg DIGITA...

Page 2: ...emember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measures Indicates a potentially hazardous situation which if not avoided MAY...

Page 3: ...OR NEAR A PERSON Loads may fall at any given time due to overloading improper load ing procedures or failure of a com ponent 8 ALWAYS DISCONNECT FROM POWER SOURCE BEFORE SERVICING Make sure switch is...

Page 4: ...0 C 14 F 104 F Operating Humidity 90 or Less Remote Control Battery 5 1 5Vx2 AA Digital Display 5 Digit LED Character Display Height 30mm Scale Body Die Cast Aluminum Case Machine Data If you have any...

Page 5: ...st the maximum loading capacity as well as any possible overloading that may occur Working Clearances Consider existing and anticipated needs dimensions of your weighing platform size of material to b...

Page 6: ...may occur Figure 2 Scale front view measurements 9 1 8 6 1 8 4 7 16 Mounting and Loading Hardware When attaching hardware to the crane scale DO NOT attach multiple chains or har nesses directly to the...

Page 7: ...f only the items that you want weighed the net weight When your scale is ready attach your weighing platform to the lifting hook at the bottom of the scale then wait until the STEADY light comes on Be...

Page 8: ...e or hold down the OFF button on the remote control Note The scale will not turn OFF unless it is at the main weighing screen If this scale is used for the selling of goods it must be Legal for Trade...

Page 9: ...igure 4 To clear the screen press the HOLD button again Advance Tare Weight To input a known tare weight before weigh ing an item press MR and the screen will display SHIFT Press TARE and the screen w...

Page 10: ...Zero 0 Display reads 0 Tare TARE TARE 0 00 Display reads 0 Tare LED is on Hold HOLD XXXXX Weight is held press HOLD to exit For quick references and questions about scale displays use the charts belo...

Page 11: ...rain on the load cell Never leave a load or weighing equipment on the scale when not in use This may cause excessive strain on the precision weighing device and may result in inaccurate read ings and...

Page 12: ...ged adaptor 2 The adaptor is not fully plugged into the scale or out let 1 Check or replace the adap tor 2 Insert the plug again Scale unable to tare 1 Damaged TARE button 1 Check and clean the button...

Page 13: ...LATE 3 PN38 HEX NUT 1 3 8 6 13 PT10008014 TARE WIRE ASSEMBLY 4 PT10009004 COTTER PIN 14 PT10008015 SCREEN 5 PT10008005 FRONT GASKET 15 PT10008016 POWER WIRE ASSEMBLY 6 PS79M PHLP HD SCR M3 5 X 8 16 PT...

Page 14: ...T10008028 1 HOOK 37 PT10008041 BATTERY CIRCUIT W WIRE ASSY 24 2 PS52M PHLP HD SCR M4 7 X 20 38 PT10008042 COUPLING HEX NUT M3 5 X 11 24 3 PT10008028 3 SAFETY LATCH 39 PLW09M LOCK WASHER 3MM 24 4 PLN01...

Page 15: ...injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our products To take advantage of this warranty contact us by mail or phone and g...

Page 16: ......

Reviews: