1.   READ  THROUGH  THE  ENTIRE 

MANUAL  BEFORE  USING. 

This 

crane scale presents serious injury 
hazards to untrained users. 

2. 

NEVER  ALLOW  UNQUALIFIED 
PERSONNEL  TO  SERVICE  THIS 
SCALE. 

Servicing  the  scale  incor-

rectly  may  reduce  the  maximum 
holding  capacity  of  the  load  cell  or 
cause  the  scale  to  give  incorrect 
readings, which may result in over-
loading.

3. 

DO  NOT  LIFT  MORE  THAN 
THE  MAXIMUM  SUGGESTED 
CAPACITY. 

Be aware that the load 

weight,  harnesses,  and  load  bear-
ing  equipment  all  contribute  to  the 
total load weight. Overloading may 
cause the load to fall.

4. 

NEVER  LIFT  HEAVY  LOADS 
WHEN  TIRED,  OR  UNDER  THE 
INFLUENCE  OF  DRUGS  OR 
ALCOHOL. 

Be mentally alert at all 

times when lifting or moving heavy 
loads.

5. 

ONLY  ALLOW  TRAINED  AND 
PROPERLY  SUPERVISED  PER-
SONNEL  TO  OPERATE  SCALE.

 

Make  sure  operation  instructions 
are safe and clearly understood.

6. 

NEVER  LEAVE  A  LOAD  WHILE 
SUSPENDED.

  Lower  the  load  to 

the  ground  and  un-hook  all  loads 
and  harnesses  before  leaving  the 
crane scale unattended.

7. 

NEVER  SUSPEND  THE  LOAD 
OVER  OR  NEAR  A  PERSON. 

Loads  may  fall  at  any  given  time 
due  to  overloading,  improper  load-
ing procedures, or failure of a com-
ponent.

8. 

ALWAYS  DISCONNECT  FROM 
POWER 

SOURCE 

BEFORE 

SERVICING

. Make sure switch is in 

OFF position, charger is unplugged, 
and  battery  disconnected  before 
servicing.

9. 

CHECK  FOR  DAMAGED  PARTS 
BEFORE  USING  SCALE.

  Check 

for  broken  parts,  loose  bolts, 
cracked  or  worn  components  and 
any  other  conditions  that  may 
affect machine operation. Repair or 
replace damaged parts.

10.  USE  RECOMMENDED  ACCES-

SORIES.

  Refer  to  the  instruction 

manual  for  recommended  acces-
sories. The use of improper acces-
sories may increase risk of injury.

11.  NEVER  LET  LOADS  SWING. 

Unsteady loads may become unbal-
anced  and  fall.  Swinging  motions 
cause  wear  on  components  and 
may cause them to break.

12.  USE  CORRECT  HARNESSES. 

Never  use  oversized  or  multiple 
harnesses.

13.  CHARGE  ONLY  USING  THE 

SUPPLIED 

CHARGER 

AND 

BATTERY.

  Do  not  use  with  other 

batteries, chargers or scales.

14.  DO  NOT  EXPOSE  BATTERY  OR 

CHARGER  TO  WET  OR  RAINY 
CONDITIONS.

  Moisture  greatly 

increases  the  risk  of  a  shock  haz-

ard.

15.  DO  NOT  STORE  BATTERY  WITH 

CONDUCTIVE MATERIALS.

 Storing 

the  battery  in  a  box  of  screws  or 

nails can cause shorting across the 

battery poles.

Safety Instructions for Crane Scales

Summary of Contents for T10009

Page 1: ...ZZLY INDUSTRIAL INC WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC JM10065 PRINTED IN CHINA MODEL T10009 5000 Kg DIGITA...

Page 2: ...emember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measures Indicates a potentially hazardous situation which if not avoided MAY...

Page 3: ...OR NEAR A PERSON Loads may fall at any given time due to overloading improper load ing procedures or failure of a com ponent 8 ALWAYS DISCONNECT FROM POWER SOURCE BEFORE SERVICING Make sure switch is...

Page 4: ...0 C 14 F 104 F Operating Humidity 90 or Less Remote Control Battery 5 1 5Vx2 AA Digital Display 5 Digit LED Character Display Height 30mm Scale Body Die Cast Aluminum Case Machine Data If you have any...

Page 5: ...st the maximum loading capacity as well as any possible overloading that may occur Working Clearances Consider existing and anticipated needs dimensions of your weighing platform size of material to b...

Page 6: ...may occur Figure 2 Scale front view measurements 9 1 8 6 1 8 4 7 16 Mounting and Loading Hardware When attaching hardware to the crane scale DO NOT attach multiple chains or har nesses directly to the...

Page 7: ...f only the items that you want weighed the net weight When your scale is ready attach your weighing platform to the lifting hook at the bottom of the scale then wait until the STEADY light comes on Be...

Page 8: ...e or hold down the OFF button on the remote control Note The scale will not turn OFF unless it is at the main weighing screen If this scale is used for the selling of goods it must be Legal for Trade...

Page 9: ...igure 4 To clear the screen press the HOLD button again Advance Tare Weight To input a known tare weight before weigh ing an item press MR and the screen will display SHIFT Press TARE and the screen w...

Page 10: ...Zero 0 Display reads 0 Tare TARE TARE 0 00 Display reads 0 Tare LED is on Hold HOLD XXXXX Weight is held press HOLD to exit For quick references and questions about scale displays use the charts belo...

Page 11: ...rain on the load cell Never leave a load or weighing equipment on the scale when not in use This may cause excessive strain on the precision weighing device and may result in inaccurate read ings and...

Page 12: ...ged adaptor 2 The adaptor is not fully plugged into the scale or out let 1 Check or replace the adap tor 2 Insert the plug again Scale unable to tare 1 Damaged TARE button 1 Check and clean the button...

Page 13: ...LATE 3 PN38 HEX NUT 1 3 8 6 13 PT10008014 TARE WIRE ASSEMBLY 4 PT10009004 COTTER PIN 14 PT10008015 SCREEN 5 PT10008005 FRONT GASKET 15 PT10008016 POWER WIRE ASSEMBLY 6 PS79M PHLP HD SCR M3 5 X 8 16 PT...

Page 14: ...T10008028 1 HOOK 37 PT10008041 BATTERY CIRCUIT W WIRE ASSY 24 2 PS52M PHLP HD SCR M4 7 X 20 38 PT10008042 COUPLING HEX NUT M3 5 X 11 24 3 PT10008028 3 SAFETY LATCH 39 PLW09M LOCK WASHER 3MM 24 4 PLN01...

Page 15: ...injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our products To take advantage of this warranty contact us by mail or phone and g...

Page 16: ......