background image

6.3. Motor vibrations meaning 

 

1x vibration - after the battery has been connected, unit performs a self-check and confirms functionality 

 

 

2x vibration - entering programming mode, saving and exiting programming mode

 

 

3x vibration - malfunction or damage detected

 

 

4x vibration - low battery detected

 

 

6x vibration - entering manual mode

 

 
6.4. Manual mode 

If your PSJ indicates damage and you are sure it is not mechanical malfunction and your replica is able to shoot, 

you can access manual mode. In this mode, malfunction is ignored and you are allowed to fire on full auto mode, 

regardless of selected fire mode or selector setting. 

 

WARNING! By poor judgement, you can cause more damage to your replica and PSJ unit!! This mode is not 

recommended for users without advanced knowledge of AEG replicas principles! 

 

To enter manual mode after your replica indicates malfunction, just pull and hold the trigger for 10 seconds. 

Entering is confirmed by 6 vibrations. 

 

7. Troubleshooting 

Is your PSJ not working correctly? Check, where the problem could be: 

7.1. Replica is not reacting at all.

 

 

Check if the battery is connected and charged properly. Also check that all wires are connected properly to 

all elements – motor, battery. 

 

If the replica is equipped with safety fuse, check if the fuse hasn’t been blown. 

7.2. Replica vibrates when battery is connected, but after that it does not react.

 

 

Problem in trigger setting. Check if your trigger is installed properly – magnet should almost touch the 

sensor when the trigger is pulled. Adjust if needed. 

7.3. Selector is set on “semi”, but acts like “auto” is selected.

 

 

Poor selector plate installation. Check, whether the magnet on the selector is directly above the sensor when 

selector is set on semi. Adjust if needed. 

7.4. Selector is set on “auto”, but acts like “semi” is selected.

 

 

Poor selector plate installation. Check, whether the magnet on the selector is away from sensor when 

selector is set on auto. Adjust if needed. 

 

Check if the fire selector is properly moving the selector plate when switched. 

 

Check if the selector plate is running smoothly in the gearbox. I fit gets jammed, adjust the selector plate or 

the gearbox to allow smooth movement. 

7.5. Replica shoots one or more shots and then vibrates 3 times.

 

 

Cut-off lever not working properly. Check if the magnet is close enough to the sensor, LED indication will 

help you. Adjust if necessary.  

 

Check if the selector plate spring is strong enough to return the cut-off lever to its base position. If not, the 

magnet might be too far from the sensor. The cut-off lever needs to return to its base position in all fire 

modes. Using stronger spring is recommended. 

 

Check if the cut-off lever is installed properly. Improper installation can result in lateral movement of cut-off 

lever during shooting, pushing it out of range of the sensor. 

7.6. Replica does not shoot, just vibrates 3 times and the vibrates with each trigger pull.

 

 

Mechanical malfunction of your replica has been detected. Check if the motor and the gears are not jammed 

and are working properly. If you are sure the replica is mechanically ok, you can access manual mode – see 

figure 6.4. 

 

Check if the selector plate is not lifting up the cut-off lever and preventing the cycle to be finished. If so, it‘s 

necessary to enlarge the area cut off of the selector plate in order not to lift the cut-off lever. 

7.7. Replica vibrates 4 times repeatedly.

 

 

Your battery is discharged. Change your battery and do not forget to charge the discharged one. 

 

If your battery is charged properly, your battery setting may be wrong – see figure 6.2 to adjust the setting. 

7.8. If your installation is unsuccessful.

 

 

If your installation is unsuccessful, you can opt to send your replica to our installation and repair center. 

Please notify us by email to [email protected]  

Address to ship your replica to: Grizzly Airsoft, Zizkova 84/7, 682 01 Vyskov, Czech Republic 

Summary of Contents for PSJ-M3 gen3

Page 1: ......

Page 2: ...now as low as 3 9mA and there are many more new features and updates Generation 3 units are suitable for AEG replicas according to the version of gearbox each unit is designed for Units have been test...

Page 3: ...r operation trigger sensitivity can be set during installation to best fit your demands 3 9 Anti reversal latch solves problem with double shot on semi anti reversal latch may not be needed if the mot...

Page 4: ...all of its content removed 5 2 PSJ M3 mounting Insert your unit into gearbox bottom side first If it does not fit properly you need to adjust gearbox Prepare gearbox for smooth unit insertion After yo...

Page 5: ...own selector plate you need to remove part of plate where it meets cut off lever Finally stick the magnet on selector so it is above the probe when selector is set on semi Magnet polarity doesn t matt...

Page 6: ...ain If you incorrect connect power source and it will cause a short circuit it will lead to irrefutable damage of your PSJ Test example connect battery power source to power wires red and black LED in...

Page 7: ...box and check if it goes smoothly If not adjust your trigger Set the trigger to position where you want your replica to fire and mark the center of the probe Now stick the magnet onto the trigger If n...

Page 8: ...Remove protective foils from both sides of heat conductive foil Place one on each transistor After that close your gearbox and check if it can be closed without any problem If not adjust gearbox Pict...

Page 9: ...wire If you don t do it and you will be test your unit it can lead to irrefutable damage of your PSJ Pict 11 Check of unit connection 5 8 Replica completion Assemble the rest of your gearbox in standa...

Page 10: ...Li Ion default 2 Li Fe 3 Off recommended for Ni MH Ni CD 3 Fire mode setting 1 Semi Burst Auto default 2 Semi Auto 3 Semi Semi 4 Semi Burst only 5 Burst only Auto 6 Burst only Burst Auto every trigger...

Page 11: ...er the magnet on the selector is away from sensor when selector is set on auto Adjust if needed Check if the fire selector is properly moving the selector plate when switched Check if the selector pla...

Page 12: ...ector plate with magnet installed dean T plug male gold plated motor plugs 2pcs gold plated fuse plugs 2pcs fuse mini heat shrink tubing user and installation manual WARNING PSJ should be installed by...

Reviews: