background image

6. Fire modes and programming

 

6.1. Preset modes 

 

Selector on semi:     Selector on auto: 

1.    Semi 

Burst / Auto 

2.  Semi 

Auto 

3.  Semi 

Semi 

4.  Semi 

Burst only 

5.  Burst only 

Auto 

6.  Burst only 

Burst / Auto 

6.2. Unit programming 

a)

    

For programming, connect a battery and within 5 seconds pull and hold the trigger for another 5 seconds. 

Entering is confirmed by the motor vibrating twice.

 

b)

    

Next, choose category from menu by pulling the trigger as many times as the category number you wish to 

select indicates. To confirm selection, pull and hold the trigger for 5 seconds. Your choice is confirmed by 

motor vibrating as many times as the selected number is and you are now in the submenu.

 

c)

    

When changing fire mode (submenu 3), every trigger pull is followed by motor vibrating as many times as 

the number of currently selected fire mode indicates. Submenu goes in circle, so number 6 is followed by 

number 1. For submenu values, refer to the table below.

 

d)

    

When you are done with setting value, pull and hold the trigger for 5 seconds to save your settings. Double 

vibration confirms successful saving and exiting programming function. Now you’re ready to go. Your 

settings stay saved even after disconnecting the battery. 

Category 

(selection is confirmed by motor 

vibrations, number of vibrations = 

number of menu selected) 

Values 

(after you select value, confirm it by holding 

the trigger pulled for 5s) 

1) Burst setting 

 

Number of trigger pulls = number of shots in burst 

(default = 3 shots) 

2) Battery check setting 

1) Li-Pol, Li-Ion (default) 

 

2) Li-Fe 

 

3) Off (recommended for Ni-MH, Ni-CD) 

3) Fire mode setting 

1) Semi - Burst/Auto (default) 

 

2) Semi - Auto 

 

3) Semi - Semi 

 

4) Semi - Burst only 

 

5) Burst only - Auto 

 

6) Burst only - Burst/Auto 

(every trigger pull is followed by motor vibrating as many times as the number of 

currently selected of fire mode is) 

4) Shooting delay setting 

Each trigger pull = +20ms 

 

(every time you set the delay, you start from the default value 

0ms, for default value, just hold the trigger pulled for 5s) 

5) Reset to default values 

(returns all settings to their default 

values) 

Hold the trigger pulled for 5s to confirm restart. If you do not wish to reset your 

settings, disconnect your battery. 

 

 

6) Rate of fire setting 

Each trigger pull = - 10% (range 100% - 10%) 

(every time you set the rate, you start from the default value 100%, for default 

value, just hold the trigger pulled for 5s) 

7) Active brake setting 

Each trigger pull = - 10% (range 100% - 0%) 

(every time you set the braking effect, you start from the default value 100%, 

for default value, just hold the trigger pulled for 5s) 

 

Example of programming: 

First, connect the battery and pull and hold the trigger for 5 seconds. Double vibration will sound. 

Then pull the trigger 3 times and then pull and hold for 5s – you‘re entering Fire mode setting. Entering is confirmed by three 

vibrations. Now pull the trigger - after each pull, vibrations will tell you which mode you‘re on. If you pulled the trigger 5 times, 

you chose number 5 (mode Burst only - Auto). Five vibrations will confirm this selection. To save it, pull and hold the trigger for 

5s. Now double vibration sounds, which means the setting is saved and the programming mode has been shut. Your replica is 

now ready with selected setting. 

 

Summary of Contents for PSJ-M3 gen3

Page 1: ......

Page 2: ...now as low as 3 9mA and there are many more new features and updates Generation 3 units are suitable for AEG replicas according to the version of gearbox each unit is designed for Units have been test...

Page 3: ...r operation trigger sensitivity can be set during installation to best fit your demands 3 9 Anti reversal latch solves problem with double shot on semi anti reversal latch may not be needed if the mot...

Page 4: ...all of its content removed 5 2 PSJ M3 mounting Insert your unit into gearbox bottom side first If it does not fit properly you need to adjust gearbox Prepare gearbox for smooth unit insertion After yo...

Page 5: ...own selector plate you need to remove part of plate where it meets cut off lever Finally stick the magnet on selector so it is above the probe when selector is set on semi Magnet polarity doesn t matt...

Page 6: ...ain If you incorrect connect power source and it will cause a short circuit it will lead to irrefutable damage of your PSJ Test example connect battery power source to power wires red and black LED in...

Page 7: ...box and check if it goes smoothly If not adjust your trigger Set the trigger to position where you want your replica to fire and mark the center of the probe Now stick the magnet onto the trigger If n...

Page 8: ...Remove protective foils from both sides of heat conductive foil Place one on each transistor After that close your gearbox and check if it can be closed without any problem If not adjust gearbox Pict...

Page 9: ...wire If you don t do it and you will be test your unit it can lead to irrefutable damage of your PSJ Pict 11 Check of unit connection 5 8 Replica completion Assemble the rest of your gearbox in standa...

Page 10: ...Li Ion default 2 Li Fe 3 Off recommended for Ni MH Ni CD 3 Fire mode setting 1 Semi Burst Auto default 2 Semi Auto 3 Semi Semi 4 Semi Burst only 5 Burst only Auto 6 Burst only Burst Auto every trigger...

Page 11: ...er the magnet on the selector is away from sensor when selector is set on auto Adjust if needed Check if the fire selector is properly moving the selector plate when switched Check if the selector pla...

Page 12: ...ector plate with magnet installed dean T plug male gold plated motor plugs 2pcs gold plated fuse plugs 2pcs fuse mini heat shrink tubing user and installation manual WARNING PSJ should be installed by...

Reviews: