Model G0897 (Mfd. Since 6/19)
-25-
SECTION 6: MAINTENANCE
Cleaning the Model G0897 is relatively easy.
Vacuum excess shavings, and wipe off any
remaining dust with a dry cloth. Never use com-
pressed air to blow away dust as airborne par-
ticles may be combustible.
Cleaning &
Protecting
To empty the spark trap, loosen the knob bolt pic-
tured in
Figure 29, until the spark trap slides free.
Remove any accumulated dust, then replace the
trap and tighten the knob bolt to secure.
Avoid storing metal dust near heat or anything
likely to produce sparks, as some types of metal
dust can be flammable.
Emptying Spark Trap
To reduce risk of shock or
accidental startup, always
disconnect machine from
power before adjustments,
maintenance, or service.
For optimum performance from this machine, this
maintenance schedule must be strictly followed.
Ongoing
To minimize your risk of injury and maintain proper
machine operation, shut down the machine imme-
diately if you ever observe any of the items below,
and fix the problem before continuing operations:
Schedule
•
Check for loose mounting bolts.
•
Check for worn or damaged belt.
•
Clean any shavings and dust from between
platen and belt.
•
Empty spark trap.
•
Sweep surrounding dust and shavings.
•
Sweep or vacuum dust and shavings from
inside belt compartment and around motor.
•
Clean/vacuum dust off motor.
Weekly/Monthly Maintenance
After Each Use
•
Loose mounting bolts.
•
Worn or damaged wires.
•
Any other unsafe condition.
Figure 29. Spark trap location.
Knob
Spark Trap
Summary of Contents for G0897
Page 36: ......