Model G0889/G0889Z (Mfd. Since 12/18)
-41-
Calibrating
Depth Stop Dial
The settings on the depth stop dial indicator are
pre-set by the factory to match the correspond-
ing measurements on the elevation scale. Over
time, the dial may need to be adjusted to maintain
accuracy. To ensure accurate depth of cut, always
follow the directions in
Calibrating Headstock
Elevation Scale before performing the steps out-
lined below.
Tools Needed
Qty
Open-Ended Wrench 12mm .............................. 1
Hex Wrench 4mm .............................................. 1
To calibrate depth stop dial:
1. DISCONNECT MACHINE FROM POWER!
2. Remove depth stop dial from machine by
pulling dial firmly outward (see
Figure 46).
Figure 47. Adjusting depth stop height.
Hex Nut
Height Stop Bolt
5. Tighten hex nut to secure setting.
6. Re-install side panel, top assembly, and dial,
and turn cutterhead elevation crank until
cutter assembly rests gently on depth stop.
Compare depth stop dial scale to cutterhead
elevation scale.
7. Repeat Steps 2–6 as needed until both
scales match.
3. Remove top assembly and side panels.
Figure 46. Removing dial from machine body.
Depth
Stop Dial
Cutterhead Elevation Scale
4. Loosen hex nut (see Figure 47) and adjust
height set screw up or down to increase or
decrease depth of cut.
Summary of Contents for G0889