Fence Scale
Calibration
The fence scale windows, shown in
Figure 126,
can be calibrated with the fence scale by loosen-
ing the mounting screws and sliding them in the
desired direction.
The indicator window on the right side is used
when the fence is positioned to the right side of
the blade. The indicator window on the left is used
when the fence is positioned on the left side of
the blade.
IMPORTANT: Do not use the fence on the left
side of the blade if it has been purposely offset,
and is not adjusted parallel with blade.
Tools Needed
Qty
Phillips Head Screwdriver #2 ............................ 1
Scrap Piece of Wood......................................... 1
Figure 126. Fence indicator windows.
Left Indicator
Window
Right Indicator
Window
To calibrate fence scale indicator windows:
1. Lock fence at 13" and cut your scrap piece of
wood.
2. Reposition and lock fence at 12", as indicated
by the scale.
3. Flip over your scrap piece of wood, placing
side that was cut in
Step 1 against fence,
then make your cut.
4. Measure width of freshly cut workpiece at
both ends with a tape measure. Workpiece
width should be exactly 12" at front and back.
If it is not, then adjust indicator window to
match width of workpiece.