Review the troubleshooting and procedures in this section to fix your machine if a problem develops. If you
need replacement parts or you are unsure of your repair skills, then feel free to call our Technical Support
at (570) 546-9663.
SECTION 7: SERVICE
Troubleshooting
Motor & Electrical
SYMPTOM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Downdraft table does not start or a fuse/
breaker trips.
1. Lockout key is missing or defective.
2. Fuse/breaker has blown.
3. Motor connection wired incorrectly.
4. Start capacitor is fault.
1. Insert/replace lockout key.
2. Correct short/replace fuse/replace
breaker.
3. Correct motor wiring connections.
4. Replace start capacitor.
Downdraft table has excessive vibration
or noisy operation.
1. Legs at fault.
2. Base shelf at fault.
3. Motor or component is loose.
1. Tighten leg bolts for stability.
2. Tighten base shelf bolts.
3. Inspect/replace stripped or damaged
bolts/nuts, and re-tighten with thread
locking fluid.
Operations
SYMPTOM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Downdraft table does not adequately
collect dust.
1. Filter bags are full.
2. Cabinet interior and fan clogged with
debris.
3. Outlet port is obstructed.
4. Motor or fan at fault.
1. Empty filter bags.
2. Remove the filter bags and vacuum
excess dust from the cabinet interior.
3. Clear the obstruction to the outlet
port. Refer to
Site Considerations
on
Page 12
for minimum space require-
ments.
4. Replace motor/fan.
Troubleshooting
Summary of Contents for G0630
Page 2: ......
Page 6: ...4 G0630 Extra Long Downdraft Table...
Page 8: ...6 G0630 Extra Long Downdraft Table...
Page 9: ...G0630 Extra Long Downdraft Table 7 Safety Instruction for Machinery...
Page 21: ...G0630 Extra Long Downdraft Table 19 Parts Breakdown...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......