![Grizzly G0452 Owner'S Manual Download Page 54](http://html1.mh-extra.com/html/grizzly/g0452/g0452_owners-manual_2267096054.webp)
-52-
Model G0452/P/Z (Mfg. Since 08/12)
READ ELECTRICAL SAFETY
ON PAGE 50 !
MOTOR
Neutral
Hot
Ground
120 VAC
SWITCH
(viewed from behind)
START
STOP
3
1
2
4
Start
Capacitor
300MFD
125VAC
Run
Capacitor
40MFD
250VAC
Ground
Ground
WARNING!
SHOCK HAZARD!
Disconnect power
before working on
wiring.
5-15 Plug
G0452Z 120V Wiring Diagram
MOTOR
SWITCH
(viewed from behind)
START
STOP
4
Start
Capacitor
300MFD
125VAC
Run
Capacitor
40MFD
250VAC
Ground
Ground
1
3
2
Hot
Hot
Ground
6-15 Plug
(As Recommended)
220
VAC
G
Bk
Wt
Gn
240 VAC
G0452Z 240V Wiring Diagram