4.3 Adjusting light beam direction
1.
Untighten the lateral screw
“3”
.
2.
Rotate the bodies of the unit towards desired direction and
tighten the screw
“3”
.
4.4 Connection to mains power
The unit can operate with voltage from 100 to 277Vac and with frequency of 50 and 60Hz.
For the connection use main cable in the side of the rear boxl of the fixture and connect as shown below.
3
3
Warning!
• Before connecting the unit, verify that power supplies features are compatible with the unit features.
• The unit must never be installed if not grounded electrically.
• It is suggested to use a magnetothermic switch along the power supply line, as prescribed by in force rules.
• The unit must not be powered up through a dimmer power device.
• Wiring and connection actions are to be performed by a qualified staff.
Live
Ground
Neutral
Brown
Yellow Green
Blue
Main supply
Warning!
Follow the instructions provided along with the connection kit to perform the connections.
English