5.1 Packaging

Check carefully the content of the box and, in case of damage, contact your forwarder immediately. The fol-

lowing items are included in the box of this unit:

n° 1 transformer box 

AL3350

n° 1 owner’s manual

5.2 Transport

It  is  recommended  to  transport  the  unit  with  the  maximum  care,  by  using  its  original  packing,  to  avoid  to

damage the unit.

6.1 Fixing

The unit can be used both rested on floor and fixed onto a structure. The unit can operate in any position.

Use  the  four  Ø5.5  holes  (0.2”)  on  the  box  in  order  to  fix  the 

device

5.0 Packaging and transport

Warning!

• Griven S.r.l. liability will cease upon consignment of goods to the forwarder: claims for damage due to trans-

port must be addressed directly to the forwarder.

• Griven S.r.l. will accept claims for broken or missing goods only within seven days of receipt of the goods.

• Returns of equipment will not be accepted without prior authorization granted by Griven S.r.l. and if not duly ac-

companied by relevant shipping documents.

6.0 Installation

Ø5,

50

0.2”

17

m

m

6.

9”

230 mm

9”

Warning!

Make sure that the structure can hold up to 10 times its weight.

English

19

Summary of Contents for AL3350

Page 1: ...TRANSFORMER BOX AL3350 Manuale di istruzioni Instructions manual...

Page 2: ...del segnale DMX 9 6 4 Collegamento dei proiettori 10 6 5 Alimentazione della scheda 10 7 0 Utilizzo del dispositivo 11 7 1 Impostazione modo di funzionamento 11 7 2 Impostazione indirizzo DMX 11 7 3...

Page 3: ...on to mains power 20 6 3 Connection to DMX signal 21 6 4 Projectors connection 22 6 5 Powering up the unit 22 7 0 Use of the unit 23 7 1 Setting operating mode 23 7 2 Setting DMX address 23 7 3 DMX fu...

Page 4: ...ti in grado di sostenerne il peso Se fissate l apparecchiatura ad una struttura sospesa sopra il livello del terreno verificare che la struttura possa sostenere almeno dieci volte il peso di tutti i d...

Page 5: ...catola 2 Pannello dip switch 3 Morsetto d alimentazione 4 Morsetto DMX 5 Connessione led 3 0 Componenti dell apparecchiatura 298 5 mm 11 8 175 mm 6 9 215 mm 8 5 230 mm 9 250 mm 9 8 5 6 mm 0 2 252 mm 9...

Page 6: ...e verificate il contenuto come descritto nel capitolo 5 0 Imballo e trasporto 2 Installate la scatola come descritto nel capitolo 6 0 Installazione 3 Svitate le 4 viti A 4 Inserire i cavi nei pressac...

Page 7: ...zionare in qualsiasi posizione Utilizzare i quattro fori 5 5 0 2 sulla scatola per fissare l appa recchiatura 5 0 Imballo e trasporto Attenzione La responsabilit di Griven S r l cessa all atto della c...

Page 8: ...le viti A rimosse in precedenza 9 MIN 12 MAX LED OFF NO DMX SIGNAL LED ON DMX SIGNAL LED FLASH AUTOMATIC MODE Cavo 3x1 5mm sezione minima L Terra N Neutro Fase Dimensioni del cavo di alimentazione H G...

Page 9: ...eguente tabella pin 1 GND pin 2 data pin 3 data In caso di apparecchi DMX con connettori a 5 poli i pin 4 e 5 non devono essere connessi Le dimensioni e lo schema di collegamento del cavo DMX sono rip...

Page 10: ...collegateli ai morsetti P Il collegamento del cavo all apparecchio deve essere effet tuato rispettando l etichetta a lato del morsetto 3 Richiudete il transformer box riavvitando le viti A rimosse in...

Page 11: ...err impostato con indirizzo 001 il secondo con indirizzo 017 il terzo 033 ecc Il numero di indirizzo DMX viene calcolato sommando i valori corrispondenti ai dip switch attivati e riportati nella parte...

Page 12: ...roiettore 2 151 160 Intensit luminosa 0 del proiettore 2 161 255 Controllo proporzionale effetto strobo 0 100 255 max del proiettore 2 9 Rosso 0 255 Controllo proporzionale 0 100 del colore Rosso del...

Page 13: ...roiettore configurato correttamente come Master il led rosso a lato del pannello dip switch lampegger Nella figura seguente riportato un esempio di configurazione di proiettore MASTER 8 2 Configurazio...

Page 14: ...lsiasi operazione sul proiettore 10 0 Ricerca dei guasti Problema Possibile causa Provvedimento Il led vicino al pannello dip switch non si accende Apparecchiatura non alimentata Controllate che i cav...

Page 15: ...e l ambiente Il simbolo del cestino barrato riportato su tutti i prodotti per ricordare gli obblighi di raccolta separata Per ulteriori informazioni sulla corretta dismissione delle apparecchiature i...

Page 16: ...hooks or any other support able to bear the weight of the unit itself If the unit is fixed onto a suspended structure this structure is supposed to bear at least ten times the weight of all devices to...

Page 17: ...witch panel 3 Power supplies terminal box 4 DMX Terminal box 5 LED terminal box 2 0 Size 298 5 mm 11 8 175 mm 6 9 215 mm 8 5 230 mm 9 250 mm 9 8 5 6 mm 0 2 252 mm 9 9 101 5mm 4 3 0 Components of the u...

Page 18: ...the content as described in the chapter 5 0 Packaging and transport 2 Install the unit as described in the chapter 6 0 Installation 3 Untighten the 4 screws A 4 Insert the cables through the cable gla...

Page 19: ...position Use the four 5 5 holes 0 2 on the box in order to fix the device 5 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods to the forwarder claims for da...

Page 20: ...following picture 3 Close the unit again by tighten the screw A previously removed Warning Before connecting the unit verify that power supplies features are compatible with the unit features The uni...

Page 21: ...ntroller the connection must respect the following table pin 1 GND pin 2 data pin 3 data For DMX devices with 5 poles connectors pins 4 and 5 are not to be connected Size and connection scheme of the...

Page 22: ...s pass through the cable glands N lo cated onto the unit body and connect to the pin P The connection of the cable to the unit must be performed re specting the label next to the terminal box 3 Close...

Page 23: ...with indipendent output the first unit will be set with address 001 the second unit with address 017 the third unit with address 033 etc 7 2 DMX functions 7 2 1 DMX functions with 4 synchronized outpu...

Page 24: ...ojector 2 151 160 Luminous output intensity 0 of projector 2 161 255 Proportional control of the strobe effect 0 100 of projector 2 9 Red 0 255 Proportional control 0 100 of the Red color of projector...

Page 25: ...perly set up as Master the red led next to the dip switch panel will flash The following pictures show some examples of MASTER units configuration 8 2 SLAVE configuration To set up the unit as SLAVE s...

Page 26: ...ce easier remember to specify the serial number and the model of the fixture which the spare parts are requested for 11 0 Troubleshooting Attention Always remove mains power prior to opening up the fi...

Page 27: ...onsumer should contact their local authority or retailer for information conceming the correct disposal of their old appliance Mechanical features Height 298 5mm 11 8 Width 252mm 9 9 Depth 101 5mm 4 W...

Page 28: ...Via Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com User s manual release 1 10...