3.1 Electrical Connection
Opening the controller:
- Remove the main cover, by untightening the 4 fixing screws
“B”
;
Fit the supply cable through the cable clip and connect it to the jun-
ction-box
“C”
. Make sure that GND, Phase and Neutral polarities are
respected.
Ensure that the cable clip screw nut is properly tightened, so that the
unit will be dust and water proofed.
A 3 poles x 1.5 mm² (minimum section) is needed for connection to
mains supply.
Connect the unit to power supply (210/240Vac - 50/60Hz).
Make sure than mains supply is correctly grounded.
3.2 DMX signal cable connection
Fit the DMX signal cable through the cable clip and connect it to the junction-box
“D”
. Make sure that the pola-
rity which is written on the label is respected (GND, DATA-, DATA+).
Ensure that the cable clip screw nut is properly tightened, so that the unit will be dust and water proofed.
The DMX signal is to be connected by using a shielded cable designed for devices RS-485, 2-pole + shield
(Shield:GND, Pin1:Data+, Pin1:Data-).