Assembly and Operating Manual

3 Warranty

4 Scope of Delivery

5 Technical Data

6 Assembly

1.

2.

To connect the electrical feedthroughs, unscrew the electric covers (pos. 3).

3.

4.

6.

7.

Rev. 1.02

3

The complete insulation elements (pos. 11 and 12) can be removed to solder the connections. 
Attention! The solder contacts are mounted in a floating manner, their movement margin may 
not be restricted after soldering (for example by cables which are too thick or by shrink tubing).

To connect the pneumatic feedthroughs, the customer-side pneumatic screw connections 
(M5), must be connected to the threaded bores at the side of the MEK. 

Subsequently the o-rings (pos. 8) and the distance bushings (pos. 5) must be pushed in and 
covers (pos. 3) must be mounted. 

The electrical plug (item 8) belongs to the MEK upper assembly, the electrical socket (pos. 7) 
belongs to the MEK lower assembly.

To adjust the upper and lower assemblies, the upper assembly (pos. 1) has to be assembled 
completely. Subsequently, the lower assemblies (pos. 2) are mechanically joined and the 
insulating body of the lower assembly is aligned by simple plugging onto the contacts of the 
upper assembly. In this case, only one position is possible (polarity-proof insulating body).

If several lower assemblies are used, this process is repeated accordingly, the upper assembly 
is always the reference piece.

Image 1

Once the connections have been completed, the insulating body must be pushed back into the 
housing as far as it will go (pos. 1 or 2).

If the product is used as intended in 1-shift operation the warranty is valid for 24 months from the ex-
works delivery date under observance the mandatory maintenance and lubrication intervals and the 
given operating conditions. Generally parts touching the work piece and wear parts are not part of the 
warranty. Wear parts are listed in chapter 8.1. The unit is considered to be defective if its basic 
function “Feeding through" is no longer functioning.

Behold technical data sheets: TD-MEK063-3PM5-1E12-EN, TD-MEK063-6PM5-1E12-EN, TD-
MEK080-6PM5-1E12-EN

5.

MEK as painted in Image 3 depending on the order number of the upper or lower assembly.

Summary of Contents for G-MEK-PM

Page 1: ...Handhabungstechnik Alter Hellweg 70 Tel 49 231 96450 01 info grip gmbh com 44379 Dortmund Germany Fax 49 231 96450 50 www grip gmbh com MEK Energy Coupling with radial pneumatic connections Rev 1 02 1 Assembly 7 1 Disassembly 6 7 4 5 8 7 3 Compressed air connection 4 Maintenance and care 9 2 3 Environmental and operating conditions 1 3 2 2 Intended use 2 Contents Operation 2 Safety 2 1 Symbol 2 2 ...

Page 2: ... must read and understand the complete operating instructions Improper use which affects the function und operational safety of the MEK Energy Coupling is prohibited The upper assembly of the MEK is mounted on the upper assembly of the MGW or SWS the lower assembly of the MEK corresponding to the lower assembly The mechanical connection of two components by means of a change system is extended by ...

Page 3: ...Subsequently the lower assemblies pos 2 are mechanically joined and the insulating body of the lower assembly is aligned by simple plugging onto the contacts of the upper assembly In this case only one position is possible polarity proof insulating body If several lower assemblies are used this process is repeated accordingly the upper assembly is always the reference piece Image 1 Once the connec...

Page 4: ...r 7 2 Torque specifications M2 5 0 5 Nm M3 1 0 Nm M4 2 0 Nm M5 4 0 Nm 7 3 Compressed air connection Requirements for compressed air according to ISO 8573 1 6 4 4 8 Parts List 8 1 Spare and wear parts depending on size Rev 1 02 4 1 Description Upper assembly Lower assembly Electric cover Distance bushing O ring Strain relief O ring EG MEK IKS Socket head screw Countersunk head screw Electrical bush...

Page 5: ...G MEK PM Assembly and Operating Manual 9 Explosion view G MEK063 6PM5 1E12 300OE G MEK063 3PM5 1E12 Rev 1 02 5 Image 2 Image 3 Upper assembly Lower assembly ...

Page 6: ...duct mentioned above may only be put into operation if it has been established applicable that the unit into which the above mentioned product is to be incorporated complies with the provisions of the Machinery Directive 2006 42 EC The provisions of the above mentioned directives including their effective amendments comply with the time of the declaration He further states that the following essen...