Grip G-MEK-PM Assembly And Operating Manual Download Page 2

G-MEK-PM

Assembly and Operating Manual

1 Operation

2 Safety

2.1 Symbol

2.2 Intended Use

2.3 Environmental and operating conditions

2.4 Safety indication

Dangers may arise from the unit, if:

the product is not installed or inserted properly,

the system is not used for its intended purpose,

the safety and installation notes are not observed. 

Rev. 1.02

2

NOTICE!
The unit may only be operated if the machine in which the unit is installed 
complies with the relevant provisions of the Machinery Directive 2006-42-EC.

CAUTION!

Before carrying out assembly, alteration, maintenance or adjustment, remove the 
power supply and carry out the necessary work outside the danger zone.

The MEK-PM Energy Coupling series has been designed to operate pneumatic and / or electrical 
equipment. The module is intended for installation in a machine. The requirements of the applicable 
instructions must be considered and adhered to. The unit may only be used in the context of its technical 
specifications.

Everyone who is responsible for assembly, commissioning and maintenance must read and 
understand the complete operating instructions. Improper use, which affects the function und 
operational safety of the MEK Energy Coupling, is prohibited.

The upper assembly of the MEK is mounted on the upper assembly of the MGW or SWS, the lower 
assembly of the MEK corresponding to the lower assembly. The mechanical connection of two 
components by means of a change system is extended by the MEK, now the pneumatic and electrical 
lines are coupled or decoupled parallel. Time-intensive disconnection of cables and hoses is no longer 
necessary.
Pneumatic and electrical connectors are integrated in both halves, which are specially designed for 
frequent plug connections and low joining forces. The MEK are graded in sizes according to the GRIP 
change systems. On the MEK-PM variant, the pneumatic feedthroughs are radially outgoing, equipped 
with metric threaded connections.

This symbol indicates possible hazards to persons or the MEK-
PM Energy Coupling.

Use this unit only in dry and splash-proof environments at room temperature as well as within the 
application parameters defined in the technical specifications. If this is not the case, warranty 
cannot be accepted. Exceptions are units designed especially for the respective conditions.

Summary of Contents for G-MEK-PM

Page 1: ...Handhabungstechnik Alter Hellweg 70 Tel 49 231 96450 01 info grip gmbh com 44379 Dortmund Germany Fax 49 231 96450 50 www grip gmbh com MEK Energy Coupling with radial pneumatic connections Rev 1 02 1 Assembly 7 1 Disassembly 6 7 4 5 8 7 3 Compressed air connection 4 Maintenance and care 9 2 3 Environmental and operating conditions 1 3 2 2 Intended use 2 Contents Operation 2 Safety 2 1 Symbol 2 2 ...

Page 2: ... must read and understand the complete operating instructions Improper use which affects the function und operational safety of the MEK Energy Coupling is prohibited The upper assembly of the MEK is mounted on the upper assembly of the MGW or SWS the lower assembly of the MEK corresponding to the lower assembly The mechanical connection of two components by means of a change system is extended by ...

Page 3: ...Subsequently the lower assemblies pos 2 are mechanically joined and the insulating body of the lower assembly is aligned by simple plugging onto the contacts of the upper assembly In this case only one position is possible polarity proof insulating body If several lower assemblies are used this process is repeated accordingly the upper assembly is always the reference piece Image 1 Once the connec...

Page 4: ...r 7 2 Torque specifications M2 5 0 5 Nm M3 1 0 Nm M4 2 0 Nm M5 4 0 Nm 7 3 Compressed air connection Requirements for compressed air according to ISO 8573 1 6 4 4 8 Parts List 8 1 Spare and wear parts depending on size Rev 1 02 4 1 Description Upper assembly Lower assembly Electric cover Distance bushing O ring Strain relief O ring EG MEK IKS Socket head screw Countersunk head screw Electrical bush...

Page 5: ...G MEK PM Assembly and Operating Manual 9 Explosion view G MEK063 6PM5 1E12 300OE G MEK063 3PM5 1E12 Rev 1 02 5 Image 2 Image 3 Upper assembly Lower assembly ...

Page 6: ...duct mentioned above may only be put into operation if it has been established applicable that the unit into which the above mentioned product is to be incorporated complies with the provisions of the Machinery Directive 2006 42 EC The provisions of the above mentioned directives including their effective amendments comply with the time of the declaration He further states that the following essen...