47
IMPORTANT! Familiarize yourself with the manufacturer’s detailed instructions on the safe
distances and installation of steel chimney elements, as well as the water tank.
Some installation options are depicted in Figure 5.
3.2.2. Heater connection
t
o a steel chimney
Steel chimneys can be used for flue gas withdrawal. As a rule, it consists of separate modules
that can be coupled with each other, and that form a single duct for flue gas withdrawal.
Chimneys can be installed directly from the heater through the ceiling and roof, or at an
angle through the wall.
If you plan to use a heater rack, for example, then take into account the height of the heater
together with the rack when preparing the hole for passage of the pipe through the wall.
The procedure for installing the pipe at an angle:
1. Install the heater on the place of permanent operation.
2. Install a water tank, if any. Keep in mind the requirements of its operations manual.
3. A valve can be installed on the connecting pipe, if additional adjustment of draft is
necessary. Install, if any.
4. Install all the necessary components of the outside chimney.
5. Insert the connecting pipe into the outside chimney.
6. Connect the heater with the pipe inserted into the outside chimney.
7. Ensure that all the pipe connections and the heater connection are reliable.
Note: when installing the chimney from the heater directly through the ceiling and roofing
system, all the elements are installed consecutively.
Note: when applying additional vertical load on the heater structure, such as: installing an
additional volume of stones, installing a chimney, installing a water tank, etc., the maximum
permissible load shall be considered. It shall be equivalent to the sum of a filled water tank with
a volume of 70 l max, and one heat-insulated chimney module with a length of one meter.
Use special unloading support platforms to reduce load, when installing a steel chimney. The
mass of the vertical part of the chimney supported by the heater, shall not be greater than
the maximum permissible one. Further, you need to install an unloading support platform
and using it, continue the chimney installation.
IMPORTANT! Familiarize yourself with the manufacturer’s detailed instructions on the safe
distances and installation of steel chimney elements, as well as the water tank.
IMPORTANT! If there is a protective shield around the stone heater, the chimney insulation
shall start at the level of the top edge of the shield or lower.
Some installation options are depicted in Figure 6.
4. WARRANTY
The warranty period for the Product is 12 months from the date of purchase by the
Consumer, but not more than 24 months from the date of shipment of the Product to the
Dealer, with the filled-in marks on the last page of this manual, namely: the date of sale, the
seller’s signature, the store’s stamp.The date of sale must be confirmed by a check or other
document.
IMPORTANT! The Manufacturer disclaims warranty liability in the absence of a store stamp.
Household usage:
the service life of products while meeting the requirements of the
Summary of Contents for Aurora
Page 24: ...24 24 615 Aurora 160 TRIO Short 460 1430 240 210 385 375 230 615 ɸ115 ...
Page 25: ...25 25 725 Aurora 160 TRIO Long 460 1430 240 210 385 375 615 230 170 ɸ115 ...
Page 26: ...26 26 750 Aurora 160 TRIO Window 460 1430 650 450 600 460 750 230 200 ɸ115 ...
Page 46: ...46 Figure 5 Stone chimney connection Figure 6 Steel chimney connection ...
Page 52: ...52 615 Aurora 160 TRIO Short 460 1430 240 210 385 375 230 615 ɸ115 ...
Page 53: ...53 725 Aurora 160 TRIO Long 460 1430 240 210 385 375 615 230 170 ɸ115 ...
Page 54: ...54 750 Aurora 160 TRIO Window 460 1430 650 450 600 460 750 230 200 ɸ115 ...
Page 80: ...80 615 Aurora 160 TRIO Short 460 1430 240 210 385 375 230 615 ɸ115 ...
Page 81: ...81 725 Aurora 160 TRIO Long 460 1430 240 210 385 375 615 230 170 ɸ115 ...
Page 82: ...82 750 Aurora 160 TRIO Window 460 1430 650 450 600 460 750 230 200 ɸ115 ...