5

INSTALLATION 

M

oun�

ng plate slots allow the chain tension to  

be adjusted through ve

r�

cal movement of the  

operator (see right) 

Alignment of door sprocket to output 

sha�

of operator 

(see l

e�

Moun ng the Unit 

The Heavy Duty operator is typically

 fl 

ag mounted below the door drum 

so  that  the  operator 

sha�

points  toward  the  door  opening  and  lies 

beneath the sprocket of the door drum. For mou

n�

ng you will need to 

either  secure  the  operator  to  the  roller 

shu�

er  head  plate  with 

prepared holes or slots, or use a 

moun�

ng plate that will 

need fi 

  xing via 

a wall angle or similar exi

s�

ng

 fi

  xture.  

 

Note: The chain guide must not be reposi oned. 

 

It  is  strongly  recommended  a  strap  be  used  to  raise  the  operator  to 

necessary height, shown right. 

The top end of the strap should be connected to a secure support beam 

above the door axle. 

 

 

 

 

 

When  assessing  and  sel

ec�

ng  an  appropriate  mou

n�

ng  lo

ca�

on,  the 

following consid

era�

ons should be made: 

M

oun�

ng Plate slots 

Distance between mou

n�

ng 

plate and door drum sprocket 

Min 15mm - Max 100mm 

Drive Chain 

Clear path for manual chain to hang downward (refer pg 6 image no. 5) 

M

oun�

ng Plate 

ACTUAL APPERANCE MAY VARY 

Summary of Contents for LiftMaster 75004A406

Page 1: ...Chamberlain Australia Pty Ltd Unit 1 75 Epping Road North Ryde NSW 2113 Australia www grifco com au D M RSO 035A B 514051 HEAVY DUTY Mechanical Industrial Door Opener...

Page 2: ...u o y g n i y f 4 g n i n n a l P Installa n o 5 8 Moun ng 5 6 Electrical Connec on 7 Compa ble Logic Control 7 Limit Switch Connec ons 8 8 t n e m t s u j d A d n a p u t e S e c n a n e t n i a M 9...

Page 3: ...nnect electric power to the commercial door opener before making repairs or removing covers Moisture and water can destroy the electronic components Make sure under all circumstances that water moistu...

Page 4: ...on the drive is suitable for the loca on Based on standard shu er The shu er is correctly spring balanced The shu er has 1 0mm x 100mm slats The shu er has no wind locks A 4 1 sprocket ra o is used I...

Page 5: ...ith prepared holes or slots or use a moun ng plate that will need xing via a wall angle or similar exis ng xture Note The chain guide must not be reposi oned It is strongly recommended a strap be used...

Page 6: ...ure hand chain is not twisted when making the join 150mm Minimum 4 The drive sprocket must be aligned with the door sprocket and locked using 2 x M8 hi tensile grub screws ghtened to min 20Nm Grub scr...

Page 7: ...cal Connec ons Motor connec on 3 phase CAUTION When Securing the Heavy Duty Operator with the 4 x x 1 long fasteners based on a 12mm moun ng plate and spring washers provided it is cri cal to ensure t...

Page 8: ...e CLOSED limit If the door doesn t move it is at the OPEN limit Con nue to Step 3 below For single button controls Supply power and push the bu on If the door travels up then the limit switch which is...

Page 9: ...Adjust if required Conduct door maintenance in accordance with door manufactures guidelines This will include door balance SERVICE MUST BE CARRIED OUT BY A QUALIFIED TECHNICIAN Notes The patented ACE...