background image

7

CAUTION

The operator 

must

be connected via an approved electrical isol

a�

on device 

be connected via a suitable circuit breaker that disconnects all live conductors 

be connected in accordance with the wiring rules of the country in which it is installed 

not have control enclosures l

e�

open for extended periods (excess dust will void warranty) 

 

It is recommended to run all cable through non

-fl

exible conduit and use appropriate conduit entries. 

However if a

 fl 

exible cable and cable gland are used, addi onal ca

ble �

es / strain relief must be

 fi� 

ed inside the enclosures to pre-

vent the cable from slipping. 

Electrical 

Connec�

ons 

 
Motor connec on 

3 phase 

   CAUTION

When Securing the Heavy Duty Operator with the 4 x ½’ x 1 ¼’ long fasteners (based on a 12mm 

moun�

ng plate) and spring 

washers provided, it is 

cri�

cal to ensure that the applied torque is between 80-90Nm.  When mou

n�

ng through thicker se

c�

ons, 

ensure a minimum of 20mm of screw thread is engaged with the female thread.  Use of incorrect fasteners or torque may cause 

serious product damage and/or personal injury.  When

 fi 

xing through a sl

o�

ed plate, ensure that the slots are no wider than 

14mm as a spring washer may not be adequate in outside diameter to support the hexagon head. 

INSTALLATION 

For compliant 

installa�

ons we recommend using the 

Li�master  GLMe2HS controller.  

For 

connec�

on details and user 

instruc�

ons refer to the GLMe2HS manual. 

COMPATIBLE LOGIC CONTROL 

Summary of Contents for LiftMaster 75004A406

Page 1: ...Chamberlain Australia Pty Ltd Unit 1 75 Epping Road North Ryde NSW 2113 Australia www grifco com au D M RSO 035A B 514051 HEAVY DUTY Mechanical Industrial Door Opener...

Page 2: ...u o y g n i y f 4 g n i n n a l P Installa n o 5 8 Moun ng 5 6 Electrical Connec on 7 Compa ble Logic Control 7 Limit Switch Connec ons 8 8 t n e m t s u j d A d n a p u t e S e c n a n e t n i a M 9...

Page 3: ...nnect electric power to the commercial door opener before making repairs or removing covers Moisture and water can destroy the electronic components Make sure under all circumstances that water moistu...

Page 4: ...on the drive is suitable for the loca on Based on standard shu er The shu er is correctly spring balanced The shu er has 1 0mm x 100mm slats The shu er has no wind locks A 4 1 sprocket ra o is used I...

Page 5: ...ith prepared holes or slots or use a moun ng plate that will need xing via a wall angle or similar exis ng xture Note The chain guide must not be reposi oned It is strongly recommended a strap be used...

Page 6: ...ure hand chain is not twisted when making the join 150mm Minimum 4 The drive sprocket must be aligned with the door sprocket and locked using 2 x M8 hi tensile grub screws ghtened to min 20Nm Grub scr...

Page 7: ...cal Connec ons Motor connec on 3 phase CAUTION When Securing the Heavy Duty Operator with the 4 x x 1 long fasteners based on a 12mm moun ng plate and spring washers provided it is cri cal to ensure t...

Page 8: ...e CLOSED limit If the door doesn t move it is at the OPEN limit Con nue to Step 3 below For single button controls Supply power and push the bu on If the door travels up then the limit switch which is...

Page 9: ...Adjust if required Conduct door maintenance in accordance with door manufactures guidelines This will include door balance SERVICE MUST BE CARRIED OUT BY A QUALIFIED TECHNICIAN Notes The patented ACE...

Page 10: ......

Page 11: ...UP DOWN ACEM ACEM ACEM...

Page 12: ...NOTES...

Reviews: