EQUIPMENT RATING
3.1
AC Input
The LineIQ Charger is meant to operate under the following conditions:
Minimum input voltage for correct operation is 100 VAC.
Absolute maximum input voltage is 240 VAC.
1.1.1
Operating frequency
50 or 60 Hz
3.1.1
Operating current
0.7 Amp maximum
3.1.2
Environmental
The LineIQ Charger is intended to operate in an office or workshop environment.
Operating tempe5°C to +60°C.
Do not allow any part of the LineIQ Charger to come into contact with liquids.
3.2
DC Output
The LineIQ Charger output is a current limited direct current (DC) output with output short
circuit protection.
When the output current falls below 30 mA, the green output LED is switched off. This is an
indication that the LineIQ battery is fully charged.
For output currents between 30 mA and 400 mA, the green output LED is switched on.
When a short circuit of the output voltage is detected, the output voltage is reduced and
pulsed on and off at approximately 1 Hz. Output current remains limited to 400 mA. In this
mode, the green output LED flashes on and off.
3.2.1
Nominal output voltage
2.5 V
3.2.2
Maximum output current
400 mA
3.2.3
Short circuit current
400 mA pulsed at 1Hz