![GridConnect CAN232 FD User Manual Download Page 13](http://html.mh-extra.com/html/gridconnect/can232-fd/can232-fd_user-manual_2264797013.webp)
CAN232 FD User Manual
2-5
2.2 Hardware Installation
2.2.1 RS232 Serial Cable
The table below lists the serial line data and control signals for the CAN232 FD. The RS232 interface is a 9-
pin D-style connector. Male connectors are wired as DTE and female connectors are wired as DCE.
CAN232 FD
Signal
Direction
(J8)
DTE DB-9 Male
Pin #
DCE DB-9
Female Pin #
Data Out (TXD)
Out (3)
3
2
Data In (RXD)
In (4)
2
3
Ground
(1)
5
5
CTS
In (6)
8
7
RTS
Out (5)
7
8
No Connection
(8)
6
4
No Connection
(9)
4
6
+9-32Vdc
In (10)
9
9
No Connection
(7)
1
1
Frame Ground
(2)
Shield
Shield
Units can be specially ordered with TTL level signals, which are connected in the same manner as the
RS232 versions.
Pin 9 on the DB-9 connector is shown with +9-32 VDC going to Pin 10 of J8. This is an optional method of
supplying power to the device. It is not required if you use a different power source. For more details about
power, see Power Options below.
2.2.2 Power Options
For the CAN-232 model, power (+9-32 VDC) can be supplied through a Phoenix terminal block, through a
barrel jack, through the serial cable (usually pin 9), or through the OEM option connector on the circuit
board. The factory default configuration is the Barrel Jack.
2.2.3 Input Power
The input power range is from 9-32VDC for the CAN-232 model.
2.2.4 OEM Options
The OEM version comes without a RS232 cable. It is designed to be part of an embedded product. Instead
of a cable connector, a 10-pin header is used to connect the signals to an OEM’s circuit board.
The CAN signals are brought out to the OEM connector at J10. The OEM connector is a 10-pin header
soldered to the bottom side of the board.