MPPT operation power, automatic and immediate adjust the solar panels output power at the maximum output 

point, then achieve a stable output purposes. 

MPPT is for short of " Maximum Power Point Tracking". It means the controller can sense the voltage of the 

solar panels on time, and can track the highest voltage and current (VI).Then made the inverter discharge to 

power grid with the highest efficiency. 

The peak voltage (Vpp) of the solar panels is about 19.5V when it in factory. And the environment 

temperature is 

25 ° C. The reason of setting this temperature(interestingly, different from the subjective 

imagination, we ordinary people the conclusion may let us surprised) is that when the weather is very 

hot, solar panels’ peak voltage will fall to about 17.5 V while in cold weather, the peak voltage can 

achieve 20.8 V.

 

Now we back to contrast the difference of MPPT solar energy grid inverter and traditional inverter. 

The traditional solar inverter is a bit like the manual gearbox. When the engine speed increase, while 

the gearbox gear don't increase at the same time, it will definitely affect the speed of the car. For 

traditional inverter speaking, the parameter output power is been set in factory. It likes a car have been 

fixed set on fixed 1 gears, no matter how powerfully you trample accelerator, the speed of a car is 

limited. While have the MPPT function it will be different, it is automatically. It will automatically adjust 

the gears according to the engine’ speed, so it can make cars in the most gears in a reasonable 

efficiency standard operation. It means the MPPT controller can track the maximum power point of solar 

panels in real-time then express the biggest efficiency of solar panels. The higher the voltage, the more 

power can be output through the MPPT. Thus improve the charging efficiency. Theoretically speaking, 

using MPPT, the efficiency can be increased by 50% compared with the traditional inverter. But due to 

environmental impact and various around energy loss, the ultimate efficiency can improve 20%-30% 

according to our actual testing. 

 

 

   

Parameter Table                                                                                                      

KD-WVC  Grid-series models

 

300Watt 500Watt 

Recommend use solar panels

 

400Wp 600Wp 

DC MAX input current 

20A 

40A 

AC MAX output power 

300Watt 

500Watt 

DC MAX Open-circuit 

input-voltage 

100VDC 

DC input voltage range 

22~60VDC 

MAX output power factor 

0.99 

DC input Reverse voltage protection

FUSE 

AC output voltage range 

120V versions

90~140VAC

)(

230V versions

180~260VAC

 

AC frequency range 

45-53Hz/55-63Hz 

Output current total   

harmonic distortion 

THDIAC <5% 

AC Phase 

<0.5% 

Islanding protection 

VAC

f AC 

Output short circuit protection 

Current-limiting 

Show 

LED mode

power instruction

voltage instruction

AC frequency instruction

over-voltage 

instruction 

Summary of Contents for TE-300W-WV

Page 1: ...1 TE 300 500W WV Series Inverters User Manual ...

Page 2: ...verter will automatic open 6 grade power search function 2 The program can automatically open power adjustment for 6 times 3 The current direction can adjust from the maximum to the minimum 4 In automatic adjustment process we will see the LOW light flashing And the power will keep as a starting point from 0 to the maximum output power and it will restart at most for 6 times then locked in the max...

Page 3: ...el will produce different current output Use advanced CPU to operate the different illuminance and the data can be directly displayed on the LCD Then you can visually see the sense of the strength of the sun unit Used more convenient 1 Luminosity sampling point power sampling point 2 High precision AD sampling integral AD sampling method Power Automatically Locked APL In different current fluctuat...

Page 4: ...ter how powerfully you trample accelerator the speed of a car is limited While have the MPPT function it will be different it is automatically It will automatically adjust the gears according to the engine speed so it can make cars in the most gears in a reasonable efficiency standard operation It means the MPPT controller can track the maximum power point of solar panels in real time then express...

Page 5: ...onnection 1 Red terminal Connect DC positive black terminal Connect DC negative Show in Figure 1 Figure 1 2 AC socket Connect to the mains Put the side of the AC cord which has holes into the inverter with 3 foot outlet and the other side of the AC cord to home 3PIN AC outlet Show in Figure 2 Figure 2 Figure 3 N W Each inverter 1 3KG 300W 500W G W Each inverter 1 8KG 300W 500W Each inverter size L...

Page 6: ...The inverter starts to work 3 Stack using In order to achieve higher power use requirements this product can be stacked such as 4 grid inverter1000W stacking can achieve 4000W And the number of the stacking is unlimited Used as shown in Figure 6 Figure 6 4 Input and output ...

Page 7: ...V 140V 60HZ Notes Non professionals do not disassemble Only qualified personnel may repair this product Please install inverter in the low humidity and well ventilated place to avoid the inverter over heating and clear around the inflammable and explosive materials When using this product avoid children touching playing to avoid electric shock Recommended Maximum DC input 4AWG cable capable of han...

Reviews: