DC input limit
Input voltage range: 22V to 60V
Solar Panel: Recommend using the power more than 30W.
1
)
Reference voltage is 18V’s solar panel. Suggest using two pieces of solar panel in series.
2
)
Reference voltage is 36V’s solar panel.
3
)
Reference voltage is 48V’s solar panel.
Recommend using multiple solar panels. Solar panel in series will result in high-input voltage which
will exceed the working voltage range of the inverter.
Wind turbine system: Rated voltage 24VDC, maximum voltage 48VDC.
2
、
AC output
:
Voltage range of the inverter whose output is 220V AC.: 180V - 260V
,
50HZ
Voltage range of the inverter whose output is 110V AC.: 90V - 140V
,
60HZ
Notes
---Non-professionals do not disassemble. Only qualified personnel may repair this product.
---Please install inverter in the low humidity and well-ventilated place to avoid the inverter over-heating,
and clear around the inflammable and explosive materials.
---When using this product, avoid children touching, playing, to avoid electric shock.
---Recommended Maximum DC input 4AWG cable capable of handling more than 50A of the
cable size.
---Optimal length of the DC input line 8M or less, long cable will allow solar panels to the inverter
DC voltage drop caused by wear and tear.
---Connected to a power outlet to provide AC.
---Connected solar panels, battery or wind generators DC input DC power supply cable.
---
Proposed wind power plant with its own charge controller and load dump.
Accessories for product
One standard AC wire
One user manual