Page 15 

MantaRay Portable Area-Velocity Flow Meter 

 

DATA LOGGING  
 
Setup 

 
Select   

Data Logging  

 from Menu Selections. 

 

Log Site ID

 

Enter a number from   

00  

 to   

99

.   The site ID will become 

part of the downloaded file name to help distinguish 
downloads from different instruments.  

 Press 

 to store the setting. 

 

Mode

  

Select   

Velocity

,   

LVT

,   

Level  

 or   

Flow

.    

 Press 

 to store the setting. 

 

Set Date

 Press 

 or 

 to scroll and select Month, Day and Year.  

 Press 

 to store the setting. 

 

Set Time

  

Press 

 or 

 to select the current time in Hours, Minutes and 

Seconds.  

 Press 

 to store the setting. 

 

Interval

  

Press 

 or 

 to select the logging interval. 

 Press 

 to store the setting. 

 

Log

 

Stop

,   

Start

   or   

Delete

   the log file.  

 Press 

 or 

 to 

Delete

 and 

 to delete the log file.  

 Press 

 or 

 to 

Start

 and 

 to start the logger. 

 

Note:

 You 

MUST delete old log and start a new log AFTER having set 

changes to 

Log Site ID

,   

Mode

   and/or   

Interval 

for those 

changes to be applied to the log file. 

 
View 24-hr formatted Reports on the MantaRay display. Press 

 from the MAIN 

display to view a formatted flow report from instruments with a built-in data 
logger. Press 

 to pan through   

Level

,   

Velocity  

 and   

Flow  

 

summaries. Press 

 to scroll down one day or repeatedly to scroll to a specific 

date. Up to 365 days can be stored. Newest date will overwrite the oldest. Press 

 

to return to the main display. 
 
 
 

 

 
 
 
 
 
 
 
 
 

--Data Logging-------

Log Site ID

00
99

Mode

Flow

Velocity

Set Date

Feb 18

/

2008

Mar 19

/

2009

Set Time

11

:

27

:

40

12

:

28

:

41

Interval

10sec
60min

30min

15min
10min

5min
2min
1min

30sec

Log

Stop

Start

Delete

}

Summary of Contents for MantaRay

Page 1: ...www greyline com USER S GUIDE Installation Operation Instructions Portable Area Velocity Flow Meter Model MantaRay Manual Series A 1 1 ...

Page 2: ...Note This page has been left blank intentionally ...

Page 3: ... FUNCTIONS 17 INSTALLATION SENSOR LOCATION 19 APPLICATIONS HOTLINE 22 PRODUCT RETURN PROCEDURE 23 AREA VELOCITY FLOW DATA SHEET 24 SPECIFICATIONS 28 IMPORTANT NOTE This instrument is manufactured and calibrated to meet product specifications Please read this manual carefully before installation and operation Any unauthorized repairs or modifications may result in a suspension of the warranty Avail...

Page 4: ...Page 4 MantaRay Portable Area Velocity Flow Meter CONNECTIONS Charger and IO Sensor USB Thumbdrive not supplied QZ02L Plug Connector Charger or optional Break out Box pg 27 see pg 28 ...

Page 5: ...battery supplies power for 48 hours continuous operation when fully charged Display brightness is adjustable to conserve power The MantaRay will switch off automatically when the battery is fully discharged Full charge requires approximately 6 to 9 hours charging Sleep mode extends battery life for long term data logging 30 days for 5 minute logging CHARGING BATTERY A 16V AC DC power module is sup...

Page 6: ...on Off Cal Constant 1 000 Restore Defaults NO New Password 0000 Data Logging Log Site ID 0 Mode Flow Set Date May 27 2013 Set Time 11 27 40 Interval 10sec Log Logging Configuration Utility 1 25 02 Sonar 1 11 Doppler 1 15 24 Logger 1 T 2 Relays Analog Out 1 Channel Setup Type Round Max Height 0 75ft Menu Selections Units Mode Calibration Channel Setup Relay Parameters Data Logging Special Functions...

Page 7: ...d File download completed Download Error Battery status charging icon No Echo Echo OK 3 2 1 External Battery Source Full charge powered by 16V adapter Battery 0 Battery 25 Battery 50 Battery 75 Battery 100 Sleep mode icon indicates that Manta ay is running in sleep mode R The icon appears only during the wake cycle when the display is fully lit ...

Page 8: ...played in ft sec or m sec Level Is displayed in the selected units Tot Displays the current totalizer reading Signal Cutoff Adjust the setting in percent to suppress flow readings at zero flow when fluid swirling or pipe vibration may cause the instrument to continue reading Example Signal Cutoff at 5 will force the display and outputs to zero when signal strength drops below 5 Signal Strength Dis...

Page 9: ...0 to 9999 prevents unauthorized access to the Calibration menu From the Main display press to get to Password Factory default password is 0000 and if it has not been changed press to proceed to the Menu Selections screen If a password is required press to place the cursor under the first digit and or to set the number then to the second digit etc Press or to proceed to the Menu Selections screen A...

Page 10: ...ss the to store your selection Press the key to move the symbol to each subsequent menu item and the to save your selections Note the volume selection bbl denotes U S barrels Temperature press then to select C or F Press or to return to the Menu Selections screen Units Mode Mode Flow Linear in Volume USG Time min Temperature C Units Mode Mode Flow Linear in ft m mm Units Mode Mode Linear Volume US...

Page 11: ...er the distance between channel floor and bottom of sensor Maximum offset is 36 914 mm Note 4mA is not affected by Lvl Offset settings 4mA is the bottom of the channel or pipe Min Vel Press and enter a minimum velocity cutoff Forward and reverse velocities less than Min Vel will be forced to zero Damping Increase damping to stabilize readings under turbulent flow readings or to reject spurious lev...

Page 12: ...gle for rectangular channels Enter the channel width Trapezoid Select Trapezoid for trapezoidal shaped channels Specify the Width and Slope of the channel as shown in the following illustration Egg Select Egg for Egg shaped channels Enter the Max Height of the channel Channel Setup Type Round Max Height 0 75ft R 3R R 2 2R HEIGHT 3R TRAPEZOIDAL CHANNEL y WIDTH x SLOPE x y ...

Page 13: ...ths for some levels Note The custom channel will interpolate widths between entry points Width Enter the measured width of the channel at the level shown Note To enter 0 width you must press and then to store a 0 width data point Level Displays the level of the channel for each increment and width entry Note Custom channel data in equal width increments with variable height measurements must be co...

Page 14: ...orinators or totalizers Minimum time between pulses is 2 25 seconds and pulse duration is 350 milliseconds Return to Relay and enter settings for each relay Velocity On Position the cursor under the numerals and press or to set digits to the relay On set point Off set digits to the Off set point Level On Position the cursor under the numerals and press or to set digits to the relay On set point Of...

Page 15: ...lete the log file Press or to Delete and to delete the log file Press or to Start and to start the logger Note You MUST delete old log and start a new log AFTER having set changes to Log Site ID Mode and or Interval for those changes to be applied to the log file View 24 hr formatted Reports on the MantaRay display Press from the MAIN display to view a formatted flow report from instruments with a...

Page 16: ...to the Log Site ID entered in the instrument Data Logging menu Download letter will be A for the first download from an instrument B for the second then C etc At the letter Z a character will appear indicating that the maximum number of downloads for that instrument are on the USB flash drive Older files can be erased or moved from the flash memory drive or a new memory drive can be used OPENING L...

Page 17: ...lect On to enable flow direction measurement Select Off to disable flow direction measurement Select Invert to invert the sense of the flow measurement Cal Constant Scales the velocity Flow reading Set to 1 000 for QZ02L sensor Restore Defaults Select Yes and press to erase all user settings and return the instrument to factory default settings New Password Select any number from 0000 to 9999 and ...

Page 18: ...alog channels Select Minimum and press to simulate minimum Flow Level and Velocity and to output 4mA 0V to the analog channels To simulate an intermediate Flow Level and Velocity set Test to Actual and then enter a value for the Level and Velocity The Flow calculation analog outputs and control relays will respond to the simulated values Simulation Test Actual Level 0 00in Velocity 10ft s Flow 198...

Page 19: ...hese flow disturbances 4 The QZ02L submerged level velocity sensor requires a minimum water level of 1 in 25 4 mm QZ02L VELOCITY LEVEL SENSOR MOUNTING Mount the QZ02L sensor with the stainless steel bracket and hardware supplied Ensure that the sensor is parallel to the water surface check with a level Mount with the tapered end of the sensor pointing upstream and the sensor cable pointing downstr...

Page 20: ...Page 20 MantaRay Portable Area Velocity Flow Meter GOOD BAD SENSOR END VIEW SENSOR END VIEW SENSOR END VIEW SENSOR END VIEW SENSOR SENSOR SENSOR FLOW SENSOR FLOW ...

Page 21: ...t and secure to the pipe wall by friction fit Insert the sensor into the mounting bracket and tie wrap the sensor cable securely to the pipe band using the holes provided OPTIONAL QZ02L DP VELOCITY SENSOR MOUNTING Mount the velocity sensor at or near the bottom of the channel or pipe in a position where it will be continuously submerged The QZ02L DP velocity sensor does not have to be parallel to ...

Page 22: ...your Sales Representative write to Greyline or phone the Applications Hotline below United States Tel 315 788 9500 Fax 315 764 0419 Canada Tel 613 938 8956 Fax 613 938 4857 Toll Free 888 473 9546 Email info greyline com Web Site www greyline com Greyline Instruments Inc Canada USA 16456 Sixsmith Drive 105 Water Street Long Sault Ont K0C 1P0 Massena NY 13662 ...

Page 23: ... Clean the Sensor Product Important unclean products will not be serviced and will be returned to the sender at their expense 1 Rinse sensor and cable to remove debris 2 If the sensor has been exposed to sewage immerse both sensor and cable in a solution of 1 part household bleach Javex Clorox etc to 20 parts water for 5 minutes Important do not immerse open end of sensor cable 3 Dry with paper to...

Page 24: ...______________ Type of Pump _________________________ Distance from nearest Pump Controlling Valve Orifice or open Discharge ___________________ Model Type _________________________ Power Input _________________________ Calibrated Range ___________________________ Indication _________________________ Operating Temp ___________________________ Alarm _________________________ Enclosure Class _______...

Page 25: ...s along with a copy of your invoice This warranty does not cover damages due to improper installation or handling acts of nature or unauthorized service Modifications to or tampering with any part shall void this warranty This warranty does not cover any equipment used in connection with the product or consequential damages due to a defect in the product All implied warranties are limited to the d...

Page 26: ...t from the nominal band size Stainless steel bracket for Sensor mounting Pre drilled for tie wraps included to secure Sensor cable VSJ PIPE MOUNTING BAND BAND ADJUSTMENT JACK SENSOR MOUNTING BRACKET Mounting Instructions Install the stainless steel pipe band with the sensor mounting bracket at the invert bottom of the pipe Ensure that the sensor bracket is parallel to the water surface check with ...

Page 27: ...antaRay Portable Area Velocity Flow Meter BREAK OUT BOX NEMA 4X IP66 DUST TIGHT SPLASH PROOF 1 EXT BATT 2 EXT BATT 3 RELAY 1 4 RELAY 1 5 RELAY 2 6 RELAY 2 7 4 20 8 4 20 9 CHARGER 10 CHARGER 1 2 3 4 5 6 7 8 9 10 ...

Page 28: ...charger input external battery input 2 relays 4 20mA 0 5V Electrical Surge Protection Sensor 4 20mA outputs and AC power input Data Logger Programmable 2 million point data capacity time and date stamped plus formatted flow reports including Total Average Minimum Maximum and times of occurrence Includes USB output to Flash Drives Logger Intervals programmable 10 30 sec 1 2 5 10 15 30 60 min Softwa...

Reviews: