10
GB
TECHNICAL DATA
Model:
WV 45-II FB
LG
/ WV 45-II FB AZ
Mains voltage:
220 - 240 V ~ 50 Hz
Power (W):
54
Protection class:
II
Degree of protection:
IPX0
No. of speeds:
3
Dimensions Ø × H × D (mm)
435 × 530 × 300
Weight (kg):
2,8
Maximum ambient temperature (°C)
0 - 35
Connection cable type:
H05VVH2-F 2 × 0.75 (2.5 m)
Place of use:
indoor only
Oscillation:
yes, approx. 85°
Battery type Remote control:
2 pcs. AAA 1,5 V
Maintenance interval:
annually
Minimum distances between walls,
fixtures and objects (cm) front:
rear:
side:
top:
40
specified by wall bracket
20
20
plastic parts.
INSTALLING THE WALL BRACKET (PAGE 78)
WARNING
:
The wall must withstand the weight and vibration of the unit!
- Use a stable and level surface.
- Adapt the fixing material (e.g. screws) to the structure of the substrate.
-
Figure 13:
Make sure that the motor unit support
is securely seated in the wall bra-
cket
.
OPERATION (page 79)
- The functions can be selected from both the fan control panel and the infrared
remote control
12
.
- The illustration fig. 14a/b shows the adjustment of the inclination of the motor unit. The
axle bolt may have to be tightened tightly.
MAINTENANCE/CLEANING NOTES
WARNING!
Electrical voltage
:
Before carrying out any cleaning or maintenance work,
remove the plug or switch off the electrical equipment from mains!
- The removal of the plug has to be such that an operator can check from any of the
points to which he has access that the plug remains removed.
- Check regularly, but most definitely before every use, the mains cable and mains plug
for damage. If any damage is visible, then further use of the unit must not be made.
- Routine maintenance must be carried out once a year, earlier if it is very dirty.