background image

H31.0.11.6C-11

User’s Manual GMH3110

page 2

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         

_______________________________________________________________________________________________________________________

  

CONTENTS

1

GENERAL................................................................................................................................................ 2

1.1

S

AFETY 

R

EQUIREMENTS

....................................................................................................................... 2

1.2

O

PERATION 

A

ND 

M

AINTAINANCE 

A

DVICE

............................................................................................... 2

1.3

C

ONNECTIONS

..................................................................................................................................... 3

1.4

D

ISPLAY

.............................................................................................................................................. 3

1.5

B

ASIC 

O

PERATION

............................................................................................................................... 3

2

CONFIGURATION ................................................................................................................................... 4

2.1

U

NIT

: C

HOICE 

O

T

HE 

D

ISPLAY 

U

NIT

.................................................................................................... 4

2.2

S

EA 

L

EVEL 

C

ORRECTION 

F

OR 

A

BSOLUTE 

P

RESSURE 

S

ENSORS

............................................................. 4

2.3

P.

O

FF: A

UTO 

P

OWER 

O

FF 

T

IME

........................................................................................................... 4

2.4

A

DR

: B

ASE 

A

DDRESS OF 

I

NTERFACE

..................................................................................................... 4

3

MEASURING OF WATER LEVEL – DISPLAY UNIT [M]......................................................................... 4

4

CALIBRATION SERVICES ...................................................................................................................... 4

5

PRESSURE CONNECTION TO THE SENSORS..................................................................................... 5

6

THE SERIAL INTERFACE ....................................................................................................................... 5

7

ERROR AND SYSTEM MESSAGES ....................................................................................................... 6

8

SPECIFICATION...................................................................................................................................... 7

9

SENSORS  

(03/2005)

............................................................................................................................... 8

10

ACCESSORIES .................................................................................................................................... 8

1 General

1.1 Safety Requirements

This device has been designed and tested in accordance with the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures
and special safety advises given in this manual will be adhered to when using the device.
1.  Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected

to any other climatic conditions than those stated under "Specification".

2.  Device and sensors have to be handled with care (don’t throw, hit, etc.). Protect plugs and sockets from

soiling.

3.  If the device is transported from a cold to a warm environment condensation may cause in a failure of the

function. In such a case make sure the device temperature has adjusted to the ambient temperature
before trying a new start-up.

4.  If device is to be connected to other devices (e.g. via serial interface) the circuitry has to be designed

most carefully. Internal connection in third party devices (e.g. connection GND and earth) may result in
not-permissible voltages impairing or destroying the device or another device connected.

Warning:

  If device is operated with a defective mains power supply (e.g. short circuit from mains voltage

to output voltage) this may result in hazardous voltages at the device (e.g. at sensor socket or interface).

5.  If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to

be marked accordingly to avoid re-starting.
Operator safety may be a risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer period of time.
In case of doubt, please return device to manufacturer for repair or maintenance.

1.2  Operation And Maintenance Advice

 

Battery Operation

If

and ´bAt´ are shown in the secondary display the battery has been used up and needs to be

replaced. The device will, however, operate correctly for a certain amount of time. If ´bAt´ is shown in the
upper display the voltage is too low to operate the device; the battery has been completely used up.
The battery has to be taken out, when storing device above 50°C.

Please note: We recommend to take out battery if device is not used for a longer period of time!

!!

Summary of Contents for GMH3110

Page 1: ...H31 0 11 6C 11 User s Manual Handheld Digital Pressure Meter GMH3110 Version 5 1 for GMSD Pressure Sensors...

Page 2: ...densation may cause in a failure of the function In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start up 4 If device is to be connected to...

Page 3: ...he left side of the device 1 4 Display 1 5 Basic Operation When switching on the device and a zero point adjustment was carried out it shows shortly nuLL Corr On Off Switch Tara Calling of tara functi...

Page 4: ...P oFF Auto Power Off Time The device will be automatically switched off if no key is pressed no interface communication takes place for the time of the power off time The power off time can be set to...

Page 5: ...ce and a suitable electrically isolated interface adapter GRS3100 GRS3105 or USB3100 the device can be connected to a computer for data transfer With the GRS3105 up to 5 devices of the GMH3xxx series...

Page 6: ...sured value far out of allowable range Check pressure not within sensor range Battery empty Replace battery Mains operation without battery wrong voltage or polarity Check power supply replace it when...

Page 7: ...o values between 1 and 120 min it can be completely deactivated Display 2 four digit LCDs 12 4mm high and 7 mm high for measuring values and for min max memories hold function etc as well as additiona...

Page 8: ...BAE 0 0 400 0 bar abs 0 1 bar 600 bar abs C Description A Sensor is suitable for air non corrosive and non ionising gases and liquids Pressure connection 2 nylon pressure ports for connection to 6 x 1...