7 Specification

Measuring
  Principle

Conductivity measuring via 2 pole graphite electrode 

  Meas. Ranges

Range

Resolution

Conductivity

0 ... 2000µS/cm

1µS/cm

0.01 ... 20.00mS/cm

0.01mS/cm

0.1 ... 100.0mS/cm

0.1mS/cm

TDS

0 ... 1999 mg/l

1mg/l

Salinity

0.0 ... 50.0 g/kg

0.1g/kg

Temperature

-5.0 ... 100.0°C

  Electrode

2 pole graphite electrode, integrated temperature sensor
Electrode material: special graphite
Dimensions: dia. 12mm, length 120mm, min immersion depth 30 mm
Cable length ca. 1.2m

  Accuracy 

±1Digit (at nominal-temperature)

Conductivity, TDS, Salinity: ±0.5% of m.v. ±0.5% FS
Temperature ±0.3K

  T.-compensation: 

non-linear temperature compensation according to EN 27888, reference temperatures 20°C and 25°C

Nominal temperature

25°C

Ambient

Temperature instrument

 -

25 ... +50°C

Temperature cell

 -

5 ... +80°C (short time 100°C)

Relative humidity instrument 0 ... 95%r.F. (non condensing)

Storage temperature  -

5 ... +50°C

Housing

Dimension: 110 x 67 x 30 mm (L x B x D)
impact resistant ABS, membrane keyboard, transparent panel.
Front side IP65

Weight

approx. 155 g

Power Supply 

9V-Battery, type IEC 6F22 (included)

Power Consumption 

<1.5mA

Display 

ca. 11 mm high, 4-digit LCD-display with additional segments

Pushbuttons 

3 membrane keys for on/off switch, menu operation, min/max/ hold-function etc.

Hold Function 

Press key to store current value.

Automatic-Off-Function 

Device will be automatically switched off if no key is pressed for the time of the power-off delay. The

power-off delay can be set to values between 1 and 120 min.; it can be completely deactivated.

EMC:

 

The device corresponds to the essential protection ratings established in the Directives of the European
Parliament and of the council on the approximation of the laws of the member states relating to the
electromagnetic compatibility (2004/108/EC). EA1 +A2 (Appendix B, class B),
additional error: < 1% FS

Summary of Contents for GLF-100

Page 1: ...UCTIVITY MEASURING 3 2 1 THE CONDUCTIVITY MEASURING CELL 3 2 2 MEASURING HINTS 3 2 3 TEMPERATURE COMPENSATION 3 2 4 MIN MAX VALUE MEMORY 3 2 5 HOLD FUNCTION 3 3 CONFIGURATION OF THE INSTRUMENT 4 4 ADJUSTING OF THE INSTRUMENT 5 5 SYSTEM MESSAGES 5 6 INSPECTION OF THE ACCURACY ADJUSTMENT SERVICES 5 7 SPECIFICATION 6 precise measurements of conductivity TDS total dissolved solids and Salinity Applica...

Page 2: ...ergency stop device or in any other application where failure of the product could result in personal injury or material damage Failure to comply with these instructions could result in death or serious injury and material damage 1 2 Operating And Maintenance If the symbol LO BAT is displayed at the left side of display the battery is weak measuring can be continued for a short period If bAt is di...

Page 3: ...hem useless very fast Measuring procedure Especially when measuring low conductivity Before immersion to the measuring solution rinse the electrode with deionised water dry with a paper towel and shake remaining water out The measuring is speeded up considerably if the electrode is immersed and pulled out the solution several times Especially when measuring low conductivity the electrode needs suf...

Page 4: ...ng of TDS 0 2000 mg l 50 0 SAL Measuring of Salinity 0 0 50 0 g kg Unit of temperature display C temperature is displayed in C factory setting F temperature is displayed in F temperature compensation only for µS cm and mS cm p r t note below oFF No temperature compensation of conductivity measuring nLF non linear temperature compensation for natural water acc to EN27888 DIN 38404 to measure ground...

Page 5: ...emperature 2 0 2 0 C 3 6 3 6 F Offset setting of temperature measurement see below Scale of temperature 5 00 5 00 Scale adjustment of temperature measurement Display measured value offset 1 scale adjustment 100 Pressing again stores the settings the instruments restarts segment test Please note If there is no key pressed within the menu mode within 60 seconds the adjusting will be cancelled the en...

Page 6: ... 100 C Relative humidity instrument 0 95 r F non condensing Storage temperature 5 50 C Housing Dimension 110 x 67 x 30 mm L x B x D impact resistant ABS membrane keyboard transparent panel Front side IP65 Weight approx 155 g Power Supply 9V Battery type IEC 6F22 included Power Consumption 1 5mA Display ca 11 mm high 4 digit LCD display with additional segments Pushbuttons 3 membrane keys for on of...

Reviews: